The DOI matches its Crossref record; 47 of the 47 references it cites were found in a registry or an index.
Perspective: The physics, diagnostics, and applications of atmospheric pressure low temperature plasma sources used in plasma medicine
Abstract
Low temperature plasmas have been used in various plasma processing applications for several decades. But it is only in the last thirty years or so that sources generating such plasmas at atmospheric pressure in reliable and stable ways have become more prevalent. First, in the late 1980s, the dielectric barrier discharge was used to generate relatively large volume diffuse plasmas at atmospheric pressure. Then, in the early 2000s, plasma jets that can launch cold plasma plumes in ambient air were developed. Extensive experimental and modeling work was carried out on both methods and much of the physics governing such sources was elucidated. Starting in the mid-1990s, low temperature plasma discharges have been used as sources of chemically reactive species that can be transported to interact with biological media, cells, and tissues and induce impactful biological effects. However, many of the biochemical pathways whereby plasma affects cells remain not well understood. This situation is changing rather quickly because the field, known today as “plasma medicine,” has experienced exponential growth in the last few years thanks to a global research community that engaged in fundamental and applied research involving the use of cold plasma for the inactivation of bacteria, dental applications, wound healing, and the destruction of cancer cells/tumors. In this perspective, the authors first review the physics as well as the diagnostics of the principal plasma sources used in plasma medicine. Then, brief descriptions of their biomedical applications are presented. To conclude, the authors' personal assessment of the present status and future outlook of the field is given.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fridman, G., Friedman, G., Gutsol, A., Shekhter, A. B., Vasilets, V. N., & Fridman, A. (2008) · Plasma Processes and Polymers · doi:10.1002/ppap.200700154 · Cited by 2,084
Graves, D. B. (2012) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/45/26/263001 · Cited by 1,518
The atmospheric-pressure plasma jet: a review and comparison to other plasma sources
Schutze, A., Jeong, J. Y., Babayan, S. E., Park, J., Selwyn, G. S., & Hicks, R. F. (1998) · IEEE Transactions on Plasma Science · doi:10.1109/27.747887 · Cited by 1,401
Lu, X., Naidis, G. V., Laroussi, M., Reuter, S., Graves, D. B., & Ostrikov, K. (2016) · Physics Reports · doi:10.1016/j.physrep.2016.03.003 · Cited by 1,230
Self-citationLow Temperature Plasma‐Based Sterilization: Overview and State‐of‐the‐Art
Laroussi, M. (2005) · Plasma Processes and Polymers · doi:10.1002/ppap.200400078 · Cited by 1,111
Self-citationMoisan, M., Barbeau, J., Moreau, S., Pelletier, J., Tabrizian, M., & Yahia, L. (2001) · International Journal of Pharmaceutics · doi:10.1016/s0378-5173(01)00752-9 · Cited by 965
Massines, F., Rabehi, A., Decomps, P., Gadri, R. B., Ségur, P., & Mayoux, C. (1998) · Journal of Applied Physics · doi:10.1063/1.367051 · Cited by 955
On atmospheric-pressure non-equilibrium plasma jets and plasma bullets
Lu, X., Laroussi, M., & Puech, V (2012) · Plasma Sources Science and Technology · doi:10.1088/0963-0252/21/3/034005 · Cited by 844
Self-citationCold plasma selectivity and the possibility of a paradigm shift in cancer therapy
Keidar, M., Walk, R., Shashurin, A., Srinivasan, P., Sandler, A., Dasgupta, S., Ravi, R., Guerrero-Preston, R., & Trink, B. (2011) · British Journal of Cancer · doi:10.1038/bjc.2011.386 · Cited by 767
Self-citationIsbary, G., Morfill, G., Schmidt, H. U., Georgi, M., Ramrath, K., Heinlin, J., Karrer, S., Landthaler, M., Shimizu, T., Steffes, B., et al. (2010) · British Journal of Dermatology · doi:10.1111/j.1365-2133.2010.09744.x · Cited by 709
Cited by
The 2022 Plasma Roadmap: low temperature plasma science and technology
Adamovich, I., Agarwal, S., Ahedo, E., Alves, L. L., Baalrud, S., Babaeva, N., Bogaerts, A., Bourdon, A., Bruggeman, P. J., Canal, C., et al. (2022) · Journal of Physics D: Applied Physics · doi:10.1088/1361-6463/ac5e1c · Cited by 536
Cold Plasma in Medicine and Healthcare: The New Frontier in Low Temperature Plasma Applications
Laroussi, M. (2020) · Frontiers in Physics · doi:10.3389/fphy.2020.00074 · Cited by 319
Self-citationZhao, Y., Shao, L., Jia, L., Zou, B., Dai, R., Li, X., & Jia, F. (2022) · Innovative Food Science & Emerging Technologies · doi:10.1016/j.ifset.2022.103051 · Cited by 38
Metadata
- Authors
- Laroussi, M., Lu, X., & Keidar, M.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2017-07-13
- Volume
- 122
- Issue
- 2
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2734424104
- Cited by
- 306
- References
- 47
- FWCI
- 19.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Perspective: The physics, diagnostics, and applications of atmospheric pressure low temperature plasma sources used in plasma medicine. https://app.cochat.ai/papers/10.1063/1.4993710
- The paper
- Laroussi, M., Lu, X., & Keidar, M. (2017). Perspective: The physics, diagnostics, and applications of atmospheric pressure low temperature plasma sources used in plasma medicine. Journal of Applied Physics. https://doi.org/10.1063/1.4993710
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.