The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Single-photon detectors combining high efficiency, high detection rates, and ultra-high timing resolution
Open accessAbstract
Single-photon detection with high efficiency, high time resolution, low dark counts, and high photon detection rates is crucial for a wide range of optical measurements. Although efficient detectors have been reported before, combining all performance parameters in a single device remains a challenge. Here, we show a broadband NbTiN superconducting nanowire detector with an efficiency exceeding 92%, over 150 MHz photon detection rate, and a dark count rate below 130 Hz operated in a Gifford-McMahon cryostat. Furthermore, with careful optimization of the detector design and readout electronics, we reach an ultra-low system timing jitter of 14.80 ps (13.95 ps decoupled) while maintaining high detection efficiencies (>75%).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gisin, N., Ribordy, G., Tittel, W., & Zbinden, H. (2002) · Reviews of Modern Physics · doi:10.1103/revmodphys.74.145 · Cited by 8,515
Counting near-infrared single-photons with 95% efficiency
Lita, A. E., Miller, A. J., & Nam, S. W. (2008) · Optics Express · doi:10.1364/oe.16.003032 · Cited by 734
Pernice, W. H. P., Schuck, C., Minaeva, O., Li, M., Goltsman, G. N., Sergienko, A. V., & Tang, H. X. (2012) · Nature Communications · doi:10.1038/ncomms2307 · Cited by 477
Cited by
Photonic quantum information processing: a review
Flamini, F., Spagnolo, N., & Sciarrino, F. (2019) · Reports on Progress in Physics · doi:10.1088/1361-6633/aad5b2 · Cited by 770
Photonic quantum information processing: a concise review
Slussarenko, S., & Pryde, G. J. (2019) · Applied Physics Reviews · doi:10.1063/1.5115814 · Cited by 644
Demonstration of sub-3 ps temporal resolution with a superconducting nanowire single-photon detector
Korzh, B., Zhao, Q.-Y., Allmaras, J. P., Frasca, S., Autry, T. M., Bersin, E. A., Beyer, A. D., Briggs, R. M., Bumble, B., Colangelo, M., et al. (2020) · Nature Photonics · doi:10.1038/s41566-020-0589-x · Cited by 564
Superconducting nanowire single-photon detectors with 98% system detection efficiency at 1550 nm
Reddy, D. V., Nerem, R. R., Nam, S. W., Mirin, R. P., & Verma, V. B. (2020) · Optica · doi:10.1364/optica.400751 · Cited by 403
Esmaeil Zadeh, I., Chang, J., Los, J. W. N., Gyger, S., Elshaari, A. W., Steinhauer, S., Dorenbos, S. N., & Zwiller, V. (2021) · Applied Physics Letters · doi:10.1063/5.0045990 · Cited by 331
Self-citation
Metadata
- Authors
- Esmaeil Zadeh, I., Los, J. W. N., Gourgues, R. B. M., Steinmetz, V., Bulgarini, G., Dobrovolskiy, S. M., Zwiller, V., & Dorenbos, S. N.
- Venue
- APL Photonics
- Publisher
- AIP Publishing
- Published
- 2017-11-01
- Volume
- 2
- Issue
- 11
- ISSN
- 2378-0967 (ISSN-L)
- OpenAlex
- W2767621545
- Cited by
- 182
- References
- 3
- FWCI
- 13.12
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Single-photon detectors combining high efficiency, high detection rates, and ultra-high timing resolution. https://app.cochat.ai/papers/10.1063/1.5000001
- The paper
- Esmaeil Zadeh, I., Los, J. W. N., Gourgues, R. B. M., Steinmetz, V., Bulgarini, G., Dobrovolskiy, S. M., Zwiller, V., & Dorenbos, S. N. (2017). Single-photon detectors combining high efficiency, high detection rates, and ultra-high timing resolution. APL Photonics. https://doi.org/10.1063/1.5000001
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.