The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Effective quality factor tuning mechanisms in micromechanical resonators
Open accessAbstract
Quality factor (Q) is an important property of micro- and nano-electromechanical (MEM/NEM) resonators that underlie timing references, frequency sources, atomic force microscopes, gyroscopes, and mass sensors. Various methods have been utilized to tune the effective quality factor of MEM/NEM resonators, including external proportional feedback control, optical pumping, mechanical pumping, thermal-piezoresistive pumping, and parametric pumping. This work reviews these mechanisms and compares the effective Q tuning using a position-proportional and a velocity-proportional force expression. We further clarify the relationship between the mechanical Q, the effective Q, and the thermomechanical noise of a resonator. We finally show that parametric pumping and thermal-piezoresistive pumping enhance the effective Q of a micromechanical resonator by experimentally studying the thermomechanical noise spectrum of a device subjected to both techniques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ladd, T. D., Jelezko, F., Laflamme, R., Nakamura, Y., Monroe, C., & O’Brien, J. L. (2010) · Nature · doi:10.1038/nature08812 · Cited by 3,592
Thermal Transport Measurements of Individual Multiwalled Nanotubes
Kim, P., Shi, L., Majumdar, A., & McEuen, P. L. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.215502 · Cited by 3,378
Positioning single atoms with a scanning tunnelling microscope
Eigler, D. M., & Schweizer, E. K. (1990) · Nature · doi:10.1038/344524a0 · Cited by 3,161
Statistics of atomic frequency standards
Allan, D. W. (1966) · Proceedings of the IEEE · doi:10.1109/proc.1966.4634 · Cited by 2,692
Laser cooling of a nanomechanical oscillator into its quantum ground state
Chan, J., Alegre, T. P. M., Safavi-Naeini, A. H., Hill, J. T., Krause, A., Gröblacher, S., Aspelmeyer, M., & Painter, O. (2011) · Nature · doi:10.1038/nature10461 · Cited by 2,311
Nanoscale thermal transport. II. 2003–2012
Cahill, D. G., Braun, P. V., Chen, G., Clarke, D. R., Fan, S., Goodson, K. E., Keblinski, P., King, W. P., Mahan, G. D., Majumdar, A., et al. (2014) · Applied Physics Reviews · doi:10.1063/1.4832615 · Cited by 1,763
Cited by
Recent Progress of Miniature MEMS Pressure Sensors
Song, P., Ma, Z., Ma, J., Yang, L., Wei, J., Zhao, Y., Zhang, M., Yang, F., & Wang, X. (2020) · Micromachines · doi:10.3390/mi11010056 · Cited by 262
Metadata
- Authors
- Miller, J. M. L., Ansari, A., Heinz, D. B., Chen, Y., Flader, I. B., Shin, D. D., Villanueva, L. G., & Kenny, T. W.
- Venue
- Applied Physics Reviews
- Publisher
- AIP Publishing
- Published
- 2018-12-01
- Volume
- 5
- Issue
- 4
- ISSN
- 1931-9401 (ISSN-L)
- OpenAlex
- W2906889225
- Cited by
- 165
- References
- 6
- FWCI
- 5.36
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.