CoChat

Perspective on training fully connected networks with resistive memories: Device requirements for multiple conductances of varying significance

Open access
Cristiano, Giorgio, Giordano, Massimo, Ambrogio, Stefano, Romero, Louis P., Cheng, Christina, Narayanan, Pritish, Tsai, Hsinyu, Shelby, Robert M., Burr, Geoffrey W. · 2018 · Journal of Applied Physics
Cited by 37

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Abstract

Novel Deep Neural Network (DNN) accelerators based on crossbar arrays of non-volatile memories (NVMs)—such as Phase-Change Memory or Resistive Memory—can implement multiply-accumulate operations in a highly parallelized fashion. In such systems, computation occurs in the analog domain at the location of weight data encoded into the conductances of the NVM devices. This allows DNN training of fully-connected layers to be performed faster and with less energy. Using a mixed-hardware-software experiment, we recently showed that by encoding each weight into four distinct physical devices—a “Most Significant Conductance” pair (MSP) and a “Least Significant Conductance” pair (LSP)—we can train DNNs to software-equivalent accuracy despite the imperfections of real analog memory devices. We surmised that, by dividing the task of updating and maintaining weight values between the two conductance pairs, this approach should significantly relax the otherwise quite stringent device requirements. In this paper, we quantify these relaxed requirements for analog memory devices exhibiting a saturating conductance response, assuming either an immediate or a delayed steep initial slope in conductance change. We discuss requirements on the LSP imposed by the “Open Loop Tuning” performed after each training example and on the MSP due to the “Closed Loop Tuning” performed periodically for weight transfer between the conductance pairs. Using simulations to evaluate the final generalization accuracy of a trained four-neuron-layer fully-connected network, we quantify the required dynamic range (as controlled by the size of the steep initial jump), the tolerable device-to-device variability in both maximum conductance and maximum conductance change, the tolerable pulse-to-pulse variability in conductance change, and the tolerable device yield, for both the LSP and MSP devices. We also investigate various Closed Loop Tuning strategies and describe the impact of the MSP/LSP approach on device endurance.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.5042462

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Metadata

Authors
Cristiano, G., Giordano, M., Ambrogio, S., Romero, L. P., Cheng, C., Narayanan, P., Tsai, H., Shelby, R. M., & Burr, G. W.
Venue
Journal of Applied Physics
Published
2018-09-25
Volume
124
Issue
15
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W2893064244
Cited by
37
References
9
FWCI
2.54
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.