Cited by 12Acoustic Wave Resonator TechnologiesUltrasonics and Acoustic Wave PropagationMicrowave and Dielectric Measurement Techniques

Temperature decoupled viscosity-density product measurement in liquid by utilizing a dual-mode AlN-based acoustic wave resonator

Zhang, Feng, Chen, Cong, Dou, Shaoxu, Zhou, Hong, Yang, Jing, Wang, Dengpan, Chen, Yu, Cheng, Yuhua +2 more·2018·Applied Physics Letters

Abstract

In this letter, we report a two-in-one acoustic wave resonator with Rayleigh and Lamb modes for temperature decoupled viscosity-density product sensing. The Lamb mode of the resonator is sensitive to both the viscosity-density product and the ambient temperature, while the Rayleigh mode only responds to the ambient temperature and is not affected by liquid properties. These unique characteristics of the two modes are due to the different spatial distributions of the acoustic energy. Taking advantage of the aforementioned features, a beat frequency strategy is proposed to decouple the temperature influence from the viscosity-density product measurement, thus realizing temperature independent viscosity-density product sensing in a single acoustic wave resonator chip. Experimental results show that the accurate measurement of the viscosity-density product can be achieved in Newtonian liquids with a sensitivity of −0.36 MHz/kg m−2 s−0.5 within a wide temperature range from 20 °C to 80 °C. Our work holds great promise for liquid property measurement occasions with large fluctuations in ambient temperature, such as oil and gas exploration, automobile, and aeronautic applications.

Integrity signals

Registry

Crossref · 10.1063/1.5047658

Cites

22 of 22 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • Acoustic wave devices based on the piezoelectric effect, semiconductor metal oxide sensors, and two-dimensional materials are representative methods for VOC detection using electrical signal output.

    “Representative methods include acoustic wave devices (AWDs) based on the piezoelectric effect (Chen et al. 2018; Dou et al. 2018; Zhang et al. 2018), semiconductor metal oxide (Lin et al. 2019), and two-dimensional materials (Sun et al. 2018).”

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Zhang, F., Chen, C., Dou, S., Zhou, H., Yang, J., Wang, D., Chen, Y., Cheng, Y., Shang, Z., & Mu, X.
Affiliations
Agency for Science, Technology and Research (SG)
Corresponding author
  • Shang, Zhengguo
  • Mu, Xiaojing
Venue
Applied Physics Letters
Published
2018-11-12
Volume
113
Issue
20
ISSN
  • 0003-6951 (ISSN-L)
  • 1077-3118
OpenAlex
W2901562116
Cited by
12
References
22
Citations by year
2025: 3 · 2024: 1 · 2023: 2 · 2022: 4 · 2021: 1 · 2019: 1
FWCI
0.20
Type
journal article
Language
en
Open access
closed
Locations
Applied Physics Letters (publishedVersion)
Funders
  • National Key Research and Development Program of China (2016YFB0402702)
  • National Natural Science Foundation of China (51605060)
Topics
  • Physical Sciences › Engineering › Biomedical Engineering › Acoustic Wave Resonator Technologies
  • Physical Sciences › Engineering › Mechanics of Materials › Ultrasonics and Acoustic Wave Propagation
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Microwave and Dielectric Measurement Techniques
Keywords
acoustic wave resonators, Rayleigh mode, Lamb modes, dual-mode resonator, beat frequency, Newtonian fluid

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review