We present the design, construction, and characterization of an experimental system capable of supporting a broad class of quantum simulation experiments with hundreds of spin qubits using 9Be+ ions in a Penning trap. This article provides a detailed overview of the core optical and trapping subsystems and their integration. We begin with a description of a dual-trap design separating loading and experimental zones and associated vacuum infrastructure design. The experimental-zone trap electrodes are designed for wide-angle optical access (e.g., for lasers used to engineer spin-motional coupling across large ion crystals) while simultaneously providing a harmonic trapping potential. We describe a near-zero-loss liquid-cryogen-based superconducting magnet, employed in both trapping and establishing a quantization field for ion spin-states and equipped with a dual-stage remote-motor LN2/LHe recondenser. Experimental measurements using a nuclear magnetic resonance (NMR) probe demonstrate part-per-million homogeneity over 7 mm-diameter cylindrical volume, with no discernible effect on the measured NMR linewidth from pulse-tube operation. Next, we describe a custom-engineered inbore optomechanical system which delivers ultraviolet (UV) laser light to the trap and supports multiple aligned optical objectives for topview and sideview imaging in the experimental trap region. We describe design choices including the use of nonmagnetic goniometers and translation stages for precision alignment. Furthermore, the optomechanical system integrates UV-compatible fiber optics which decouple the system’s alignment from remote light sources. Using this system, we present site-resolved images of ion crystals and demonstrate the ability to realize both planar and three-dimensional ion arrays via control of rotating wall electrodes and radial laser beams. Looking to future work, we include interferometric vibration measurements demonstrating root-mean-square trap motion of ∼33 nm (∼117 nm) in the axial (transverse) direction; both values can be reduced when operating the magnet in free-running mode. The paper concludes with an outlook toward extensions of the experimental setup, areas for improvement, and future experimental studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.5049506

Cites

32 of 32 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 32 references

Cited by

See all 18

Metadata

Authors
Ball, H., Marciniak, C. D., Wolf, R. N., Hung, A. T.-H., Pyka, K., & Biercuk, M. J.
Venue
Review of Scientific Instruments
Published
2019-05-01
Volume
90
Issue
5
Pages
053103-053103
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W2810899480
Cited by
18
References
32
FWCI
1.00
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Site-resolved imaging of beryllium ion crystals in a high-optical-access Penning trap with inbore optomechanics. https://app.cochat.ai/papers/10.1063/1.5049506
The paper
Ball, H., Marciniak, C. D., Wolf, R. N., Hung, A. T.-H., Pyka, K., & Biercuk, M. J. (2019). Site-resolved imaging of beryllium ion crystals in a high-optical-access Penning trap with inbore optomechanics. Review of Scientific Instruments. https://doi.org/10.1063/1.5049506

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.