Rare-earth high entropy alloys with hexagonal close-packed structure
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The formation of octonary DyErGdHoLuScTbY and senary DyGdHoLaTbY and ErGdHoLaTbY high-entropy alloys (HEAs) with the hexagonal close-packed (HCP) structure was reported in this study. Experiments using scanning electron microscopy and x-ray diffraction confirmed the single HCP solid solution in the as-cast state for these three HEAs if the presence of minor rare-earth oxides due to contamination from processing is ignored. The measured compressive yield stress values for these HEAs at room temperature are 245, 205, and 360 MPa for the ErGdHoLaTbY, DyGdHoLaTbY, and DyErGdHoLuScTbY HEAs, respectively. The corresponding solid solution strengthening contributions for these HEAs were estimated using a simple elastic model, and the resulting contributions were 28 MPa, 27 MPa, and 42 MPa for the three aforementioned HEAs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Effect of valence electron concentration on stability of fcc or bcc phase in high entropy alloys
Guo, S., Ng, C., Lu, J., & Liu, C. T. (2011) · Journal of Applied Physics · doi:10.1063/1.3587228 · Cited by 2,911
A hexagonal close-packed high-entropy alloy: The effect of entropy
Zhao, Y. J., Qiao, J. W., Ma, S. G., Gao, M. C., Yang, H. J., Chen, M. W., & Zhang, Y. (2016) · Materials & Design · doi:10.1016/j.matdes.2016.01.149 · Cited by 446
Self-citationFeuerbacher, M., Heidelmann, M., & Thomas, C. (2015) · Materials Research Letters · doi:10.1080/21663831.2014.951493 · Cited by 308
Cited by
George, E. P., Raabe, D., & Ritchie, R. O. (2019) · Nature Reviews Materials · doi:10.1038/s41578-019-0121-4 · Cited by 5,047
Additive manufacturing of magnetic materials
Chaudhary, V., Mantri, S. A., Ramanujan, R. V., & Banerjee, R. (2020) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100688 · Cited by 275
Superconductivity in high and medium entropy alloys based on MoReRu
Lee, Y.-S., & Cava, R. J. (2019) · Physica C: Superconductivity and its Applications · doi:10.1016/j.physc.2019.1353520 · Cited by 49
Superconductivity in a uranium containing high entropy alloy
Nelson, W. L., Chemey, A. T., Hertz, M., Choi, E., Graf, D. E., Latturner, S., Albrecht-Schmitt, T. E., Wei, K., & Baumbach, R. E. (2020) · Scientific Reports · doi:10.1038/s41598-020-61666-z · Cited by 47
Superconducting properties of new hexagonal and noncentrosymmetric cubic high entropy alloys
Motla, K., Arushi, Jangid, S., Meena, P. K., Kushwaha, R. K., & Singh, R. P. (2023) · Superconductor Science and Technology · doi:10.1088/1361-6668/acfac5 · Cited by 28
Wu, L., Si, J., Guan, S., Zhang, H., Dou, J., Luo, J., Yang, J., Yu, H., Zhang, J., Ma, X., et al. (2024) · Physical Review Letters · doi:10.1103/physrevlett.132.166002 · Cited by 28
Metadata
- Authors
- Qiao, J. W., Bao, M. L., Zhao, Y. J., Yang, H. J., Wu, Y. C., Zhang, Y., Hawk, J. A., & Gao, M. C.
- Venue
- Journal of Applied Physics
- Publisher
- AIP Publishing
- Published
- 2018-11-15
- Volume
- 124
- Issue
- 19
- ISSN
- 0021-8979 (ISSN-L)
- 1089-7550
- OpenAlex
- W2900738150
- Cited by
- 89
- References
- 3
- FWCI
- 5.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.