CoChat

Generation and detection of millimeter waves by picosecond photoconductivity

Auston, D. H., Smith, P. R. · 1983 · Applied Physics Letters
Cited by 121

The DOI matches its Crossref record.

Abstract

Picosecond photoconductors in the form of dielectric resonators have been used to generate and detect extremely short bursts of millimeter wave radiation at 55 GHz with a repetition rate of 100 MHz. Both the generator and detector are tuned to a frequency which is determined by the length of the photoconducting dielectric resonators. The detector, which is phase coherent, has an estimated noise equivalent power of only 4×10−11 W for an integration bandwidth of 1 Hz, and is capable of resolving time intervals corresponding to a small fraction of one millimeter-wave cycle.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1063/1.94468

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 121

Metadata

Authors
Auston, D. H., & Smith, P. R.
Venue
Applied Physics Letters
Published
1983-10-01
Volume
43
Issue
7
Pages
631-633
ISSN
  • 0003-6951 (ISSN-L)
  • 1077-3118
OpenAlex
W2047003489
Cited by
121
References
0
FWCI
3.33
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Generation and detection of millimeter waves by picosecond photoconductivity. https://app.cochat.ai/papers/10.1063/1.94468
The paper
Auston, D. H., & Smith, P. R. (1983). Generation and detection of millimeter waves by picosecond photoconductivity. Applied Physics Letters. https://doi.org/10.1063/1.94468

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.