Accuracy of sample material parameters reconstruction using terahertz pulsed spectroscopy

Zaytsev, Kirill I., Gavdush, Arseniy A., Karasik, Valeriy E., Alekhnovich, Valentin I., Nosov, Pavel A., Lazarev, Vladimir A., Reshetov, Igor V., Yurchenko, Stanislav O. · 2014 · Journal of Applied Physics

The DOI matches its Crossref record; 69 of the 69 references it cites were found in a registry or an index.

Abstract

New experimental and theoretical results for the material parameter reconstruction using terahertz (THz) pulsed spectroscopy (TPS) are presented. The material parameter reconstruction algorithm was realized and experimentally implemented to study the test sample. In order to both verify the algorithm and to estimate the reconstruction accuracy, test sample material parameters obtained with the TPS were compared with the results of the same sample studying by the use of the backward-wave oscillator (BWO) spectroscopy. Thus, high reconstruction accuracy was demonstrated for the spectral range, corresponding to the BWO sensitivity and located between 0.2 and 1.2 THz. The numerical simulations were applied for determining the material parameter reconstruction stability in the presence of white Gaussian noise in TPS waveforms as well as fluctuations in the femtosecond (FS) optical pulse duration. We report a strong dependence of the inverse problem solution stability on these factors. We found that the instability of the FS optical pulse duration used for THz pulses generation and detection limits the material parameter reconstruction with TPS.

Overview

Integrity signals

Registry

Crossref · 10.1063/1.4876324

Cites

69 of 69 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 69 references

Cited by

See all 53

Metadata

Authors
Zaytsev, K. I., Gavdush, A. A., Karasik, V. E., Alekhnovich, V. I., Nosov, P. A., Lazarev, V. A., Reshetov, I. V., & Yurchenko, S. O.
Affiliations
  • Bauman Moscow State Technical University (RU)
  • Bauman Moscow State Technical University 1 , 105005, 2nd Baumanskaya street 5, Moscow, Russia
  • P.A. Hertzen Moscow Oncology Research Institute (RU)
Venue
Journal of Applied Physics
Published
2014-05-20
Volume
115
Issue
19
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W1981816661
Cited by
53
References
69
Citations by year
2023: 4 · 2022: 2 · 2021: 5 · 2020: 3 · 2019: 8 · 2018: 8 · 2017: 4 · 2016: 5 · 2015: 12 · 2014: 2
FWCI
4.07
Type
journal article
Language
en
Open access
closed
Locations
Journal of Applied Physics (publishedVersion)
Funders
RFBR (14-08-31102)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Terahertz technology and applications
  • Physical Sciences › Mathematics › Mathematical Physics › Numerical methods in inverse problems
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Microwave and Dielectric Measurement Techniques
Keywords
inverse problems, reconstruction accuracy, Gaussian white noise

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Accuracy of sample material parameters reconstruction using terahertz pulsed spectroscopy. https://app.cochat.ai/papers/10.1063/1.4876324
The paper
Zaytsev, K. I., Gavdush, A. A., Karasik, V. E., Alekhnovich, V. I., Nosov, P. A., Lazarev, V. A., Reshetov, I. V., & Yurchenko, S. O. (2014). Accuracy of sample material parameters reconstruction using terahertz pulsed spectroscopy. Journal of Applied Physics. https://doi.org/10.1063/1.4876324

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.