The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Atomic force microscopy of liquid-covered surfaces: Atomic resolution images
Abstract
Images of graphite surfaces that are covered with oil reveal the hexagonal rings of carbon atoms. Images of a sodium chloride surface, protected from moisture by oil, exhibit a monoatomic step. Together, these images demonstrate the potential of atomic force microscopy (AFM) for studying both conducting and nonconducting surfaces, even surfaces covered with liquids. Our AFM uses a cross of double wires with an attached diamond stylus as a force sensor. The force constant is ≊40 N/m. The resonant frequency is ≊3 kHz. The lateral and vertical resolutions are 0.15 nm and 5 pm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Binnig, G., Quate, C. F., & Gerber, C. (1986) · Physical Review Letters · doi:10.1103/physrevlett.56.930 · Cited by 14,762
Review of Progress in Quantitative Nondestructive Evaluation: Volume 15A
(1996) · Springer eBooks · doi:10.1007/978-1-4613-0383-1 · Cited by 1,963
(1993) · Methods in Experimental Physics · doi:10.1016/s0076-695x(08)x6001-6 · Cited by 1,776
Atomic Resolution with Atomic Force Microscope
Binnig, G., Gerber, C., Stoll, E., Albrecht, T. R., & Quate, C. F. (1987) · Europhysics Letters (EPL) · doi:10.1209/0295-5075/3/12/006 · Cited by 559
The Topografiner: An Instrument for Measuring Surface Microtopography
Young, R., Ward, J., & Scire, F. (1972) · Review of Scientific Instruments · doi:10.1063/1.1685846 · Cited by 336
Voltage-dependent scanning-tunneling microscopy of a crystal surface: Graphite
Selloni, A., Carnevali, P., Tosatti, E., & Chen, C. D. (1985) · Physical review. B, Condensed matter · doi:10.1103/physrevb.31.2602 · Cited by 324
Erratum: Voltage-dependent scanning-tunneling microscopy of a crystal surface: Graphite
Selloni, A., Carnevali, P., Tosatti, E., & Chen, C. D. (1986) · Physical review. B, Condensed matter · doi:10.1103/physrevb.34.7406.2 · Cited by 240
Sonnenfeld, R., Schneir, J., Drake, B., Hansma, P. K., & Aspnes, D. E. (1987) · Applied Physics Letters · doi:10.1063/1.97734 · Cited by 63
Self-citation
Cited by
Calcium Carbonate Formation and Dissolution
Morse, J. W., Arvidson, R. S., & Lüttge, A. (2007) · Chemical Reviews · doi:10.1021/cr050358j · Cited by 1,228
Scratching the Surface: Fundamental Investigations of Tribology with Atomic Force Microscopy
Carpick, R. W., & Salmeron, M. (1997) · Chemical Reviews · doi:10.1021/cr960068q · Cited by 1,126
Imaging Crystals, Polymers, and Processes in Water with the Atomic Force Microscope
Drake, B., Prater, C. B., Weisenhorn, A. L., Gould, S. A. C., Albrecht, T. R., Quate, C. F., Cannell, D. S., Hansma, H. G., & Hansma, P. K. (1989) · Science · doi:10.1126/science.2928794 · Cited by 1,033
Self-citationThe dissolution kinetics of major sedimentary carbonate minerals
Morse, J. W., & Arvidson, R. S. (2002) · Earth-Science Reviews · doi:10.1016/s0012-8252(01)00083-6 · Cited by 766
True Atomic Resolution by Atomic Force Microscopy Through Repulsive and Attractive Forces
Ohnesorge, F., & Binnig, G. (1993) · Science · doi:10.1126/science.260.5113.1451 · Cited by 700
Metadata
- Authors
- Marti, O., Drake, B., & Hansma, P. K.
- Venue
- Applied Physics Letters
- Publisher
- AIP Publishing
- Published
- 1987-08-17
- Volume
- 51
- Issue
- 7
- Pages
- 484-486
- ISSN
- 0003-6951 (ISSN-L)
- 1077-3118
- OpenAlex
- W2065452626
- Cited by
- 303
- References
- 8
- FWCI
- 11.27
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.