CoChat

Suppression of current source noise with an atomic magnetometer

Shen, Liang, Zhang, Rui, Wu, Teng, Peng, Xiang, Yu, Song, Chen, Jingbiao, Guo, Hong · 2020 · Review of Scientific Instruments

The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.

Abstract

This paper introduces a method for using an atomic magnetometer to suppress current source noise. In this method, the current noise is (i) suppressed with a lamp-pumped cesium atomic magnetometer and (ii) measured with a higher-sensitivity laser-pumped cesium atomic magnetometer. The current noise is compared before and after noise suppression at an output current of 50 mA, and the noise-suppression ratio is ∼27 dB. The noise-suppression performance can be enhanced by improving the sensitivity of the atomic magnetometer and the ability to restrain the ambient magnetic noise. This method has practical applications in metrology and fundamental physics research.

Overview

Integrity signals

Registry

Crossref · 10.1063/5.0009987

Cites

27 of 27 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 27 references

Research works printed but not linked: 2

  1. 2007, Phase-Lock Basics
  2. 2013, Optical Magnetometry

Cited by

Metadata

Authors
Shen, L., Zhang, R., Wu, T., Peng, X., Yu, S., Chen, J., & Guo, H.
Affiliations
  • Beijing University of Posts and Telecommunications (CN)
  • National University of Defense Technology (CN)
  • Peking University (CN)
Corresponding author
Peng, Xiang
Venue
Review of Scientific Instruments
Published
2020-08-01
Volume
91
Issue
8
Pages
084701-084701
ISSN
  • 0034-6748 (ISSN-L)
  • 1089-7623
OpenAlex
W3047322357
Cited by
16
References
27
Citations by year
2026: 5 · 2025: 3 · 2023: 4 · 2022: 3 · 2021: 1
FWCI
0.81
Type
journal article
Language
en
Open access
closed
Locations
  • Review of Scientific Instruments (publishedVersion)
  • PubMed (publishedVersion)
Funders
National Natural Science Foundation of China (61531003, 61571018)
Topics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Atomic and Subatomic Physics Research
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Magnetic Field Sensors Techniques
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Electrical Measurement Techniques
Keywords
noise reduction, atomic magnetometer, magnetometer sensitivity

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.