CoChat

Cathode temperature measurement of a hydrogen self-field MPD thruster during 1 ms quasi-steady operation

Oshio, Yuya, Tauchi, Shitan, Kawasaki, Akira, Funaki, Ikkoh · 2021 · Journal of Applied Physics

The DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.

Abstract

In this study, a 2D two-color pyrometer was developed to measure the cathode surface temperature distribution of a high-power hydrogen magnetoplasmadynamic thruster. The developed measurement system consists of an object lens, a beam splitter, bandpass filters, and two cameras. Wavelengths of 950 and 980 nm were selected to achieve a high signal-to-noise ratio by reducing the effects of plasma radiation. The cathode temperature distribution was measured in a discharge current range of 6–13 kA during approximately 1 ms quasi-steady operation. A spot-like high-temperature region over 3000 K and an overall low temperature were observed at low discharge currents. The overall cathode tip region was heated to approximately 2800 K at high discharge currents. The temperature distribution with high temperature only near the cathode tip was measured during quasi-steady operation, the duration of which is shorter than the duration of thermal conduction. These results show that the discharge current distribution near the cathode is stable during the time scale of sub-milliseconds. We confirmed that this temperature distribution remains constant during a 1 ms duty cycle through cathode temperature measurements at each operation time with a 0.2 ms exposure time. The measurement error was approximately 10% of the calculated temperature; a cross-check was performed utilizing near-infrared spectrum measurements.

Overview

Integrity signals

Registry

Crossref · 10.1063/5.0063942

Cites

30 of 30 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 30 references

Research works printed but not linked: 1

  1. 1970, Emission Properties of Materials, 198

Cited by

Metadata

Authors
Oshio, Y., Tauchi, S., Kawasaki, A., & Funaki, I.
Affiliations
  • Ryukoku University (JP)
  • The Graduate University for Advanced Studies, SOKENDAI (JP)
  • Nagoya University (JP)
  • Japan Aerospace Exploration Agency (JP)
Corresponding author
Oshio, Yuya
Venue
Journal of Applied Physics
Published
2021-11-03
Volume
130
Issue
17
ISSN
  • 0021-8979 (ISSN-L)
  • 1089-7550
OpenAlex
W3208662993
Cited by
8
References
30
Citations by year
2025: 1 · 2024: 3 · 2023: 1 · 2022: 3
FWCI
0.51
Type
journal article
Language
en
Open access
closed
Locations
Journal of Applied Physics (publishedVersion)
Funders
Japan Society for the Promotion of Science (20H05656)
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Low-Pressure Plasma Processing and Diagnostics
  • Physical Sciences › Physics and Astronomy › Atomic and Molecular Physics, and Optics › Vacuum and Plasma Arcs
  • Physical Sciences › Engineering › Aerospace Engineering › Electromagnetic Launch and Propulsion Technology
Keywords
magnetoplasmadynamic thruster, two-color pyrometer, high-power electric propulsion, plasma radiation

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.