Design, calibration and calculation for flow-through respirometry systems
The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.
Abstract
Flow-through respirometry systems that measure oxygen consumption (VO2), carbon dioxide production (VCO2) and evaporative water loss (EWL) require the accurate calibration of the flow meter and three separate analysers (O2, CO2 and H2O vapour). Correct measurement of VO2, VCO2 and EWL depends on the incurrent air flow (VI) and its condition (e.g. dry, CO2-free), and the excurrent air flow (VE) and its condition (e.g. dry, CO2-free), which can differ in different parts of the excurrent circuit. Usually either VI or VE is measured and the other is calculated from the gas composition. I describe here a procedure for precise calibration of CO2 and H2O analysers in a flow-through respirometry system by reference to a calibrated O2 analyser, using a small gas flame. Generic equations are derived for calculation of VO2, VO2 and EWL with a variety of configurations for a flow-through respirometry system. Procedures for selection of data from continuous records of VO2, VCO2 and EWL for calculation of minimal (basal or standard) values are briefly described. Finally, the importance of the correct order of data treatment prior to calculation is described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Robust Locally Weighted Regression and Smoothing Scatterplots
Cleveland, W. S. (1979) · Journal of the American Statistical Association · doi:10.1080/01621459.1979.10481038 · Cited by 11,594 · cited 1×
“Another procedure for smoothing is lowess (locally-weighted scatterplot smoother), which is essentially a low-pass digital filter algorithm (Cleveland 1979).”
BackgroundJung, F. T. (1962) · JAMA · doi:10.1001/jama.1962.03050110085031 · Cited by 1,797
Saturated Solutions For the Control of Humidity in Biological Research
Winston, P. W., & Bates, D. H. (1960) · Ecology · doi:10.2307/1931961 · Cited by 1,796
Measurement of VO2, VCO2, and evaporative water loss with a flow-through mask
Withers, P. C. (1977) · Journal of Applied Physiology · doi:10.1152/jappl.1977.42.1.120 · Cited by 866
Self-citationIntroduction to signal processing
Orfanidis, S. J. (1995) · Medical Entomology and Zoology · Cited by 827
Statistics for Management and Economics.
Lowther, J., Keller, G., & Warwick, B. (1997) · The Journal of the Operational Research Society · doi:10.2307/3010500 · Cited by 800
Determination of oxygen consumption by use of the paramagnetic oxygen analyzer.
Hill, R. W. (1972) · Journal of Applied Physiology · doi:10.1152/jappl.1972.33.2.261 · Cited by 584 · cited 3×
“This equation is essentially accurate if CO2 is not removed from the incurrent air and is removed from the excurrent air, but a more substantial error occurs if CO2 is not removed from the excurrent air (Hill 1972; Koteja 1996).”
BackgroundMethodDepocas, F., & Hart, J. S. (1957) · Journal of Applied Physiology · doi:10.1152/jappl.1957.10.3.388 · Cited by 553
Bartholomew, G. A., Vleck, D. B. V., & Vleck, C. M. (1981) · Journal of Experimental Biology · doi:10.1242/jeb.90.1.17 · Cited by 463
One-step N2-dilution technique for calibrating open-circuit VO2 measuring systems
Fedak, M. A., Rome, L., & Seeherman, H. J. (1981) · Journal of Applied Physiology · doi:10.1152/jappl.1981.51.3.772 · Cited by 337
Lasiewski, R. C., Acosta, A. L., & Bernstein, M. H. (1966) · Comparative Biochemistry and Physiology · doi:10.1016/0010-406x(66)90153-8 · Cited by 302
Measuring Energy Metabolism with Open-Flow Respirometric Systems: Which Design to Choose?
Koteja, P. (1996) · Functional Ecology · doi:10.2307/2390179 · Cited by 158 · cited 2×
“This equation is essentially accurate if CO2 is not removed from the incurrent air and is removed from the excurrent air, but a more substantial error occurs if CO2 is not removed from the excurrent air (Hill 1972; Koteja 1996).”
BackgroundThe accuracy of the bubble meter method for gas flow measurements
Levy, A. (1964) · Journal of Scientific Instruments · doi:10.1088/0950-7671/41/7/309 · Cited by 149
Aminul, M., Talukder, H., Talukder, M. A. H., & Talukder, A. H. (1999) · Choice Reviews Online · doi:10.5860/choice.37-0956 · Cited by 144
Energy expenditure for thermoregulation and locomotion in emperor penguins
Pinshow, B., Fedak, M. A., Dr, B., & Schmidt‐Nielsen, K. (1976) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1976.231.3.903 · Cited by 137
Mechanisms of thermal stability during flight in the honeybee Apis mellifera
Roberts, S. P., & Harrison, J. F. (1999) · Journal of Experimental Biology · doi:10.1242/jeb.202.11.1523 · Cited by 118
Oxygen Consumption During Hover-Feeding in Free-Ranging Anna Hummingbirds
Bartholomew, G. A., & Lighton, J. R. B. (1986) · Journal of Experimental Biology · doi:10.1242/jeb.123.1.191 · Cited by 111
Hayes, J. P., Speakman, J. R., & Racey, P. A. (1992) · Physiological Zoology · doi:10.1086/physzool.65.3.30157972 · Cited by 107 · cited 1×
“However, calculating values for a specific length of time introduces a systematic bias into the estimation of minimum values, and the calculation interval should be considered a covariate in the calculations (Hayes et al. 1992).”
BackgroundSeymour, R. S., Withers, P. C., & Weathers, W. W. (1998) · Journal of Zoology · doi:10.1111/j.1469-7998.1998.tb00012.x · Cited by 101
Self-citationEffect of air temperature on the rate of energy metabolism in the English sparrow
Kendeigh, S. C. (1944) · Journal of Experimental Zoology · doi:10.1002/jez.1400960102 · Cited by 99
Withers, P. C., Thompson, G. G., & Seymour, R. S. (2000) · Australian Journal of Zoology · doi:10.1071/zo99073 · Cited by 74 · cited 1×
“4 for a marsupial mole (Notoryctes caurinus) (Withers et al. 2000) includes a few quiescent periods interspersed with other more variable periods.”
BackgroundSelf-citationUnderstanding respirometry chambers: What goes in must come out
Frappell, P. B., Blevin, H. A., & Baudinette, R. V. (1989) · Journal of Theoretical Biology · doi:10.1016/s0022-5193(89)80046-3 · Cited by 63 · cited 2×
“To determine ‘instantaneous’ VO2, VCO2 and EWL (Bartholomew et al. 1981; Frappell et al. 1989; Bakken 1991; Seymour et al. 1998), it may therefore be necessary to correct for differences in lag-time for analyser responses as well as washout characteristics (which can vary for different analysers as the air stream beco…”
BackgroundCalibration methods in respiratory calorimetry
Young, B. A., Fenton, T. W., & McLean, J. A. (1984) · Journal of Applied Physiology · doi:10.1152/jappl.1984.56.4.1120 · Cited by 56 · cited 4×
“pure CO2 or dry ice, or N2 (Fedak et al. 1981; Young et al. 1984; Bakken 1991; Mortola et al. 1992).”
BackgroundInfluentialVentilation and Oxygen Consumption in Agamid Lizards
Frappell, P. B., & Daniels, C. B. (1991) · Physiological Zoology · doi:10.1086/physzool.64.4.30157953 · Cited by 35 · cited 1×
“Analytical formulae for many combinations of flow-sensing and O2, CO2 and/or H2O analysis have been described by various authors for steady-state (e.g. Depocas and Hart 1957; Lasiewski et al. 1966; Hill 1972; Withers 1977; Frappell and Daniels 1991; Bakken 1991) and for ‘instantaneous’ nonsteady-state (Bartholomew et…”
MethodTemperature regulation and basal metabolic rate in the spotted skunk, Spilogale putorius
Knudsen, K. L., & Kilgore, D. L. (1990) · Comparative Biochemistry and Physiology Part A Physiology · doi:10.1016/0300-9629(90)90717-7 · Cited by 19
Cited by
Energy metabolism and animal personality
Careau, V., Thomas, D., Humphries, M. M., & Réale, D. (2008) · Oikos · doi:10.1111/j.0030-1299.2008.16513.x · Cited by 888
WILSON, R. P., WHITE, C. R., QUINTANA, F., HALSEY, L. G., LIEBSCH, N., MARTIN, G. R., & BUTLER, P. J. (2006) · Journal of Animal Ecology · doi:10.1111/j.1365-2656.2006.01127.x · Cited by 797
“oxygen consumption (VO , ml min-') and carbon dioxide production (Vco, ml min-') were recorded using standard positive pressure open-flow respirometry (Withers 2001).”
MethodLighton, J. R. B. (2008) · Oxford University Press eBooks · doi:10.1093/acprof:oso/9780195310610.001.0001 · Cited by 739
Jung, C. M., Melanson, E. L., Frydendall, E. J., Perreault, L., Eckel, R. H., & Wright, K. P. (2011) · The Journal of Physiology · doi:10.1113/jphysiol.2010.197517 · Cited by 318
Determinants of inter-specific variation in basal metabolic rate
White, C. R., & Kearney, M. R. (2013) · Journal of Comparative Physiology B · doi:10.1007/s00360-012-0676-5 · Cited by 216
“…(Porter and Kearney 2009), as well as to the empirically determined scaling exponent of minimum wet thermal conductance (b = 0.42–0.62: Schleucher and Withers 2001; Withers et al. 2006), and the scaling exponent of daily energy expenditure (DEE) measured at any given temperature (Calder 1984).”
BackgroundMethodInfluential
Metadata
- Authors
- Withers, P. C.
- Venue
- Australian Journal of Zoology
- Publisher
- CSIRO Publishing
- Published
- 2001-09-26
- Volume
- 49
- Issue
- 4
- Pages
- 445-461
- ISSN
- 0004-959X (ISSN-L)
- 1446-5698
- OpenAlex
- W1686762661
- Cited by
- 238
- References
- 25
- FWCI
- 5.41
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.