The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
High throughput DNA sequencing with a microfabricated 96-lane capillary array electrophoresis bioprocessor
Open accessAbstract
High throughput DNA sequencing has been performed by using a microfabricated 96-channel radial capillary array electrophoresis (μCAE) microchannel plate detected by a 4-color rotary confocal fluorescence scanner. The microchannel plate features a novel injector for uniform sieving matrix loading as well as high resolution, tapered turns that provide an effective separation length of 15.9 cm on a compact 150-mm diameter wafer. Expanded common buffer chambers for the cathode, anode, and waste reservoirs are used to simplify electrode addressing and to counteract buffering capacity depletion arising from the high electrophoretic current. DNA sequencing data from 95 successful lanes out of 96 lanes run in parallel were batch-processed with basefinder , producing an average read length of 430 bp (phred q ≥ 20). Phred quality values were found to exceed 40 (0.01% probability of incorrectly calling a base) for over 80% of the read length. The μCAE system demonstrated here produces sequencing data at a rate of 1.7 kbp/min, a 5-fold increase over current commercial capillary array electrophoresis technology. Additionally, this system permits lower reagent volumes and lower sample concentrations, and it presents numerous possibilities for integrated sample preparation and handling. The unique capabilities of μCAE technology should make it the next generation, high performance DNA sequencing platform.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Initial sequencing and analysis of the human genome
International Human Genome Sequencing Consortium, Whitehead Institute for Biomedical Research, C. F. G. R., Lander, E. S., Linton, L. M., Birren, B., Nusbaum, C., Zody, M. C., Baldwin, J., Devon, K., Dewar, K., et al. (2001) · Nature · doi:10.1038/35057062 · Cited by 24,216
Base-Calling of Automated Sequencer Traces Using Phred. I. Accuracy Assessment
Ewing, B., Hillier, L., Wendl, M. C., & Green, P. (1998) · Genome Research · doi:10.1101/gr.8.3.175 · Cited by 6,967
Base-Calling of Automated Sequencer Traces Using Phred. II. Error Probabilities
Ewing, B., & Green, P. (1998) · Genome Research · doi:10.1101/gr.8.3.186 · Cited by 5,439
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
High-performance electrophoresis
Hjertén, S. (1985) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)95485-8 · Cited by 1,513
New Goals for the U.S. Human Genome Project: 1998-2003
Collins, F. S., Patrinos, A., Jordan, E., Chakravarti, A., Gesteland, R., Walters, L., & groups, T. M. O. T. D. A. N. P. (1998) · Science · doi:10.1126/science.282.5389.682 · Cited by 854
Woolley, A. T., Hadley, D., Landre, P., deMello, A. J., Mathies, R. A., & Northrup, M. A. (1996) · Analytical Chemistry · doi:10.1021/ac960718q · Cited by 730
Self-citationJacobson, S. C., Hergenroder, R., Koutny, L. B., Warmack, R. J., & Ramsey, J. M. (1994) · Analytical Chemistry · doi:10.1021/ac00079a028 · Cited by 669
Woolley, A. T., & Mathies, R. A. (1994) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.91.24.11348 · Cited by 605
Self-citationUltra-High-Speed DNA Sequencing Using Capillary Electrophoresis Chips
Woolley, A. T., & Mathies, R. A. (1995) · Analytical Chemistry · doi:10.1021/ac00116a010 · Cited by 564
Self-citationHigh-Speed DNA Genotyping Using Microfabricated Capillary Array Electrophoresis Chips
Woolley, A. T., Sensabaugh, G. F., & Mathies, R. A. (1997) · Analytical Chemistry · doi:10.1021/ac961237+ · Cited by 310
Self-citationRuiz-Martinez, M. C., Berka, J., Belenkii, A., Foret, F., Miller, A. W., & Karger, B. L. (1993) · Analytical Chemistry · doi:10.1021/ac00068a023 · Cited by 244
Simpson, P. C., Roach, D., Woolley, A. T., Thorsen, T., Johnston, R., Sensabaugh, G. F., & Mathies, R. A. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.5.2256 · Cited by 234
Self-citationDNA Sequencing on Microfabricated Electrophoretic Devices
Schmalzing, D., Adourian, A. S., Koutny, L. B., Ziaugra, L., Matsudaira, P. T., & Ehrlich, D. J. (1998) · Analytical Chemistry · doi:10.1021/ac971381a · Cited by 210
Dispersion Sources for Compact Geometries on Microchips
Culbertson, C. T., Jacobson, S. C., & Ramsey, J. M. (1998) · Analytical Chemistry · doi:10.1021/ac9804487 · Cited by 181
Zhou, H., Miller, A. W., Sosic, Z., Buchholz, B. A., Barron, A. E., Kotler, L., & Karger, B. L. (2000) · Analytical Chemistry · doi:10.1021/ac991117c · Cited by 134
DNA sequencing using a four‐color confocal fluorescence capillary array scanner
Kheterpal, I., Scherer, J. R., Clark, S. M., Radhakrishnan, A., Ju, J., Ginther, C., Sensabaugh, G. F., & Mathies, R. A. (1996) · Electrophoresis · doi:10.1002/elps.1150171209 · Cited by 104
Self-citationTian, H., Brody, L. C., Fan, S., Huang, Z., & Landers, J. P. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.2.173 · Cited by 53
Cited by
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Micro Total Analysis Systems. 2. Analytical Standard Operations and Applications
Auroux, P.-A., Iossifidis, D., Reyes, D. R., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac020239t · Cited by 1,532
Integrated microfluidic devices
Erickson, D., & Li, D. (2004) · Analytica Chimica Acta · doi:10.1016/j.aca.2003.09.019 · Cited by 726
Microfluidic Devices for Bioapplications
Yeo, L. Y., Chang, H., Chan, P. P. Y., & Friend, J. R. (2011) · Small · doi:10.1002/smll.201000946 · Cited by 622
Grover, W. H., Skelley, A. M., Liu, C. N., Lagally, E. T., & Mathies, R. A. (2003) · Sensors and Actuators B: Chemical · doi:10.1016/s0925-4005(02)00468-9 · Cited by 517
Self-citation
Metadata
- Authors
- Paegel, B. M., Emrich, C. A., Wedemayer, G. J., Scherer, J. R., & Mathies, R. A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2002-01-15
- Volume
- 99
- Issue
- 2
- Pages
- 574-579
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1984662125
- Cited by
- 263
- References
- 19
- FWCI
- 24.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.