The DOI matches its Crossref record.
Functional Integration of PCR Amplification and Capillary Electrophoresis in a Microfabricated DNA Analysis Device
Abstract
Microfabricated silicon PCR reactors and glass capillary electrophoresis (CE) chips have been successfully coupled to form an integrated DNA analysis system. This construct combines the rapid thermal cycling capabilities of microfabricated PCR devices (10 degrees C/s heating, 2.5 degrees C/s cooling) with the high-speed (< 120 s) DNA separations provided by microfabricated CE chips. The PCR chamber and the CE chip were directly linked through a photolithographically fabricated channel filled with hydroxyethylcellulose sieving matrix. Electrophoretic injection directly from the PCR chamber through the cross injection channel was used as an "electrophoretic valve" to couple the PCR and CE devices on-chip. To demonstrate the functionality of this system, a 15 min PCR amplification of a beta-globin target cloned in M13 was immediately followed by high-speed CE chip separation in under 120 s, providing a rapid PCR-CE analysis in under 20 min. A rapid assay for genomic Salmonella DNA was performed in under 45 min, demonstrating that challenging amplifications of diagnostically interesting targets can also be performed. Real-time monitoring of PCR target amplification in these integrated PCR-CE devices is also feasible. Amplification of the beta-globin target as a function of cycle number was directly monitored for two different reactions starting with 4 x 10(7) and 4 x 10(5) copies of DNA template. This work establishes the feasibility of performing high-speed DNA analyses in microfabricated integrated fluidic systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Fully integrated PCR-capillary electrophoresis microsystem for DNA analysis
Lagally, E. T., Emrich, C. A., & Mathies, R. A. (2001) · Lab on a Chip · doi:10.1039/b109031n · Cited by 284
Self-citationPreservation of key biomolecules in the fossil record: current knowledge and future challenges
Bada, J. L., Wang, X. S., & Hamilton, H. (1999) · Philosophical Transactions of the Royal Society of London. Series B: Biological Sciences · doi:10.1098/rstb.1999.0361 · Cited by 147
Durney, B. C., Crihfield, C. L., & Holland, L. A. (2015) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-015-8703-5 · Cited by 92
Metadata
- Authors
- Woolley, A. T., Hadley, D., Landre, P., deMello, A. J., Mathies, R. A., & Northrup, M. A.
- Venue
- Analytical Chemistry
- Publisher
- American Chemical Society (ACS)
- Published
- 1996-12-01
- Volume
- 68
- Issue
- 23
- Pages
- 4081-4086
- ISSN
- 0003-2700 (ISSN-L)
- 1520-6882
- OpenAlex
- W2007762328
- Cited by
- 730
- References
- 0
- FWCI
- 43.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Functional Integration of PCR Amplification and Capillary Electrophoresis in a Microfabricated DNA Analysis Device. https://app.cochat.ai/papers/10.1021/ac960718q
- The paper
- Woolley, A. T., Hadley, D., Landre, P., deMello, A. J., Mathies, R. A., & Northrup, M. A. (1996). Functional Integration of PCR Amplification and Capillary Electrophoresis in a Microfabricated DNA Analysis Device. Analytical Chemistry. https://doi.org/10.1021/ac960718q
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.