Expanded dynamic range of fluorescent indicators for Ca 2+ by circularly permuted yellow fluorescent proteins
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
Fluorescence resonance energy transfer (FRET) technology has been used to develop genetically encoded fluorescent indicators for various cellular functions. Although most indicators have cyan- and yellow-emitting fluorescent proteins (CFP and YFP) as FRET donor and acceptor, their poor dynamic range often prevents detection of subtle but significant signals. Here, we optimized the relative orientation of the two chromophores in the Ca(2+) indicator, yellow cameleon (YC), by fusing YFP at different angles. We generated circularly permuted YFPs (cpYFPs) that showed efficient maturation and acid stability. One of the cpYFPs incorporated in YC absorbs a great amount of excited energy from CFP in its Ca(2+)-saturated form, thereby increasing the Ca(2+)-dependent change in the ratio of YFP/CFP by nearly 600%. Both in cultured cells and in the nervous system of transgenic mice, the new YC enables visualization of subcellular Ca(2+) dynamics with better spatial and temporal resolution than before. Our study provides an important guide for the development and improvement of indicators using GFP-based FRET.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Ratiometric imaging using FRET-based calcium indicators, such as yellow cameleon (YC) indicators (Horikawa et al., 2010; Nagai et al., 2004; Yamada et al., 2011), is another approach that has the advantage of reduced sensitivity to motion artifacts and essentially permits quantification of calcium concentration levels.”
From Transgenic mice for intersectional targeting of neural sensors and effectors with high specificity and performance (2015) · cites this paper as Nagai et al., 2004
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Tsien, R. Y. (1998) · Annual Review of Biochemistry · doi:10.1146/annurev.biochem.67.1.509 · Cited by 6,143
Efficient selection for high-expression transfectants with a novel eukaryotic vector
Hitoshi, N., Ken-ichi, Y., & Jun-ichi, M. (1991) · Gene · doi:10.1016/0378-1119(91)90434-d · Cited by 5,134
Fluorescent indicators for Ca2+based on green fluorescent proteins and calmodulin
Miyawaki, A., Llopis, J., Heim, R., McCaffery, J. M., Adams, J. A., Ikura, M., & Tsien, R. Y. (1997) · Nature · doi:10.1038/42264 · Cited by 3,248
Self-citationNagai, T., Ibata, K., Park, E. S., Kubota, M., Mikoshiba, K., & Miyawaki, A. (2002) · Nature Biotechnology · doi:10.1038/nbt0102-87 · Cited by 2,753
Self-citationA high signal-to-noise Ca2+ probe composed of a single green fluorescent protein
Nakai, J., Ohkura, M., & Imoto, K. (2001) · Nature Biotechnology · doi:10.1038/84397 · Cited by 1,616
Reducing the Environmental Sensitivity of Yellow Fluorescent Protein
Griesbeck, O., Baird, G. S., Campbell, R. E., Zacharias, D. A., & Tsien, R. Y. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m102815200 · Cited by 1,023
Circularly permuted green fluorescent proteins engineered to sense Ca 2+
Nagai, T., Sawano, A., Park, E. S., & Miyawaki, A. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.051636098 · Cited by 966
Self-citationCircular permutation and receptor insertion within green fluorescent proteins
Baird, G. S., Zacharias, D. A., & Tsien, R. Y. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.20.11241 · Cited by 961
Dynamic and quantitative Ca 2+ measurements using improved cameleons
Miyawaki, A., Griesbeck, O., Heim, R., & Tsien, R. Y. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.5.2135 · Cited by 823
Self-citationVisualization of the Spatial and Temporal Dynamics of Intracellular Signaling
Miyawaki, A. (2003) · Developmental Cell · doi:10.1016/s1534-5807(03)00060-1 · Cited by 455
Self-citation
Cited by
Ultrasensitive fluorescent proteins for imaging neuronal activity
Chen, T.-W., Wardill, T. J., Sun, Y., Pulver, S. R., Renninger, S. L., Baohan, A., Schreiter, E. R., Kerr, R. A., Orger, M. B., Jayaraman, V., et al. (2013) · Nature · doi:10.1038/nature12354 · Cited by 6,474
The Fluorescent Toolbox for Assessing Protein Location and Function
Giepmans, B. N. G., Adams, S. R., Ellisman, M. H., & Tsien, R. Y. (2006) · Science · doi:10.1126/science.1124618 · Cited by 2,770
Fluorescent Proteins and Their Applications in Imaging Living Cells and Tissues
Chudakov, D. M., Matz, M. V., Lukyanov, S., & Lukyanov, K. A. (2010) · Physiological Reviews · doi:10.1152/physrev.00038.2009 · Cited by 1,375
Grienberger, C., & Konnerth, A. (2012) · Neuron · doi:10.1016/j.neuron.2012.02.011 · Cited by 1,354
Optimization of a GCaMP Calcium Indicator for Neural Activity Imaging
Akerboom, J., Chen, T.-W., Wardill, T. J., Tian, L., Marvin, J. S., Mutlu, S., Calderón, N. C., Esposti, F., Borghuis, B. G., Sun, X. R., et al. (2012) · The Journal of Neuroscience · doi:10.1523/jneurosci.2601-12.2012 · Cited by 1,223
Metadata
- Authors
- Nagai, T., Yamada, S., Tominaga, T., Ichikawa, M., & Miyawaki, A.
- Affiliations
- Kyoto University (JP)
- Corresponding author
- Miyawaki, Atsushi
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2004-07-09
- Volume
- 101
- Issue
- 29
- Pages
- 10554-10559
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC490022
- OpenAlex
- W1980726951
- Cited by
- 1,030
- References
- 15
- Citations by year
- 2026: 15 · 2025: 16 · 2024: 38 · 2023: 34 · 2022: 36 · 2021: 46 · 2020: 46 · 2019: 53 · 2018: 52 · 2017: 59 · 2016: 49 · 2015: 66 · 2014: 46 · 2013: 92 · 2012: 74
- FWCI
- 21.62
- Type
- journal article
- Language
- en
- Open access
- green
- europepmc.org
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- Funders
- Japan Science and Technology Agency (CREST)
- Core Research for Evolutional Science and Technology
- Precursory Research for Embryonic Science and Technology
- Topics
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Advanced Fluorescence Microscopy Techniques
- Physical Sciences › Chemistry › Spectroscopy › Molecular Sensors and Ion Detection
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › bioluminescence and chemiluminescence research
- Keywords
- calcium sensor, circularly permuted GFP, fluorescence resonance energy transfer, dynamic range, genetically encoded fluorescent indicators, chromophore orientation, transgenic mice
- MeSH terms
- Animals, Bacterial Proteins, Calcium, Fluorescent Dyes, HeLa Cells, Humans, Luminescent Proteins, Microscopy, Fluorescence, Models, Molecular, Molecular Sequence Data, Protein Conformation, Fluorescence Resonance Energy Transfer, Mice
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Expanded dynamic range of fluorescent indicators for Ca 2+ by circularly permuted yellow fluorescent proteins. https://app.cochat.ai/papers/10.1073/pnas.0400417101
- The paper
- Nagai, T., Yamada, S., Tominaga, T., Ichikawa, M., & Miyawaki, A. (2004). Expanded dynamic range of fluorescent indicators for Ca 2+ by circularly permuted yellow fluorescent proteins. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0400417101
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.