The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Improved peptide identification in proteomics by two consecutive stages of mass spectrometric fragmentation
Open accessAbstract
MS-based proteomics usually involves the fragmentation of tryptic peptides (tandem MS or MS 2 ) and their identification by searching protein sequence databases. In ion trap instruments fragments can be further fragmented and analyzed, a process termed MS/MS/MS or MS 3 . Here, we report that efficient ion capture in a linear ion trap leads to MS 3 acquisition times and spectra quality similar to those for MS 2 experiments with conventional 3D ion traps. Fragmentation of N- or C-terminal ions resulted in informative and low-background spectra, even at subfemtomol levels of peptide. Typically C-terminal ions are chosen for further fragmentation, and the MS 3 spectrum greatly constrains the C-terminal amino acids of the peptide sequence. MS 3 spectra allow resolution of ambiguities in identification, a crucial problem in proteomics. Because of the sensitivity and rapid scan rates of the linear ion trap, several MS 3 spectra per peptide can be obtained even when sequencing very complex mixtures. We calculate the probability that an experimental MS 3 spectrum originates from fragmentation of a given N- or C-terminal ion of a peptide under consideration. This MS 3 identification score can be combined with the MS 2 scores of the precursor peptide from existing search engines. When MS 3 is performed on the linear ion trap–Fourier transform mass spectrometer combination, accurate peptide masses further increase confidence in peptide identification.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Perkins, D. N., Pappin, D. J. C., Creasy, D. M., & Cottrell, J. S. (1999) · Electrophoresis · doi:10.1002/(sici)1522-2683(19991201)20:18<3551::aid-elps3551>3.0.co;2-2 · Cited by 8,203
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Self-citationMass spectrometry-based proteomics
Aebersold, R., & Mann, M. (2003) · Nature · doi:10.1038/nature01511 · Cited by 6,955
Self-citationEng, J. K., McCormack, A. L., & Yates, J. R. (1994) · Journal of the American Society for Mass Spectrometry · doi:10.1016/1044-0305(94)80016-2 · Cited by 6,484
Keller, A., Nesvizhskii, A. I., Kolker, E., & Aebersold, R. (2002) · Analytical Chemistry · doi:10.1021/ac025747h · Cited by 4,830
A Statistical Model for Identifying Proteins by Tandem Mass Spectrometry
Nesvizhskii, A. I., Keller, A., Kolker, E., & Aebersold, R. (2003) · Analytical Chemistry · doi:10.1021/ac0341261 · Cited by 4,809
Rappsilber, J., Ishihama, Y., & Mann, M. (2003) · Analytical Chemistry · doi:10.1021/ac026117i · Cited by 2,644
Self-citationRoepstorff, P., & Fohlman, J. (1984) · Biological Mass Spectrometry · doi:10.1002/bms.1200111109 · Cited by 2,633
Fourier transform ion cyclotron resonance mass spectrometry: A primer
Marshall, A. G., Hendrickson, C. L., & Jackson, G. S. (1998) · Mass Spectrometry Reviews · doi:10.1002/(sici)1098-2787(1998)17:1<1::aid-mas1>3.0.co;2-k · Cited by 1,990
Peng, J., Elias, J. E., Thoreen, C. C., Licklider, L. J., & Gygi, S. P. (2003) · Journal of Proteome Research · doi:10.1021/pr025556v · Cited by 1,647
Error-Tolerant Identification of Peptides in Sequence Databases by Peptide Sequence Tags
Mann, M., & Wilm, M. (1994) · Analytical Chemistry · doi:10.1021/ac00096a002 · Cited by 1,468
Self-citationTrypsin Cleaves Exclusively C-terminal to Arginine and Lysine Residues
Olsen, J. V., Ong, S.-E., & Mann, M. (2004) · Molecular & Cellular Proteomics · doi:10.1074/mcp.t400003-mcp200 · Cited by 1,254
Self-citationThe abc's (and xyz's) of peptide sequencing
Steen, H., & Mann, M. (2004) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm1468 · Cited by 1,150
Self-citationUnbiased quantitative proteomics of lipid rafts reveals high specificity for signaling factors
Foster, L. J., de Hoog, C. L., & Mann, M. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0631608100 · Cited by 834
Self-citationA two-dimensional quadrupole ion trap mass spectrometer
Schwartz, J. C., Senko, M. W., & Syka, J. E. P. (2002) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(02)00384-7 · Cited by 796
Proteomics: the first decade and beyond
Patterson, S. D., & Aebersold, R. H. (2003) · Nature Genetics · doi:10.1038/ng1106 · Cited by 745
Proteomics: the move to mixtures
Peng, J., & Gygi, S. P. (2001) · Journal of Mass Spectrometry · doi:10.1002/jms.229 · Cited by 648
A new linear ion trap mass spectrometer
Hager, J. W. (2002) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.607 · Cited by 479
Appendix 5. Nomenclature for peptide fragment ions (positive ions)
Biemann, K. (1990) · Methods in Enzymology · doi:10.1016/0076-6879(90)93460-3 · Cited by 431
Probability-Based Validation of Protein Identifications Using a Modified SEQUEST Algorithm
MacCoss, M. J., Wu, C. C., & Yates, J. R. (2002) · Analytical Chemistry · doi:10.1021/ac025826t · Cited by 377
Syka, J. E. P., Marto, J. A., Bai, D. L., Horning, S., Senko, M. W., Schwartz, J. C., Ueberheide, B., Garcia, B., Busby, S., Muratore, T., et al. (2004) · Journal of Proteome Research · doi:10.1021/pr0499794 · Cited by 348
Prediction of Low-Energy Collision-Induced Dissociation Spectra of Peptides
Zhang, Z. (2004) · Analytical Chemistry · doi:10.1021/ac049951b · Cited by 281
Anderson, D. C., Li, W., Payan, D. G., & Noble, W. S. (2003) · Journal of Proteome Research · doi:10.1021/pr0255654 · Cited by 210
Large-scale protein identification using mass spectrometry
Lin, D., Tabb, D. L., & Yates, J. R. (2003) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/s1570-9639(02)00546-0 · Cited by 210
Improving large‐scale proteomics by clustering of mass spectrometry data
Beer, I., Barnea, E., Ziv, T., & Admon, A. (2004) · PROTEOMICS · doi:10.1002/pmic.200300652 · Cited by 183
Tabb, D. L., Huang, Y., Wysocki, V. H., & Yates, J. R. (2004) · Analytical Chemistry · doi:10.1021/ac0351163 · Cited by 160
Automatic Identification of Proteins with a MALDI-Quadrupole Ion Trap Mass Spectrometer
Krutchinsky, A. N., Kalkum, M., & Chait, B. T. (2001) · Analytical Chemistry · doi:10.1021/ac010682o · Cited by 144
Mass Spectrometry: Analytical Capabilities and Potentials
Cooks, R. G., Busch, K. L., & Glish, G. L. (1983) · Science · doi:10.1126/science.6353576 · Cited by 76
Cited by
Cox, J., & Mann, M. (2008) · Nature Biotechnology · doi:10.1038/nbt.1511 · Cited by 14,855
Self-citationUniversal sample preparation method for proteome analysis
Wiśniewski, J. R., Zougman, A., Nagaraj, N., & Mann, M. (2009) · Nature Methods · doi:10.1038/nmeth.1322 · Cited by 8,352
Self-citationAndromeda: A Peptide Search Engine Integrated into the MaxQuant Environment
Cox, J., Neuhauser, N., Michalski, A., Scheltema, R. A., Olsen, J. V., & Mann, M. (2011) · Journal of Proteome Research · doi:10.1021/pr101065j · Cited by 5,500
Self-citationIn-gel digestion for mass spectrometric characterization of proteins and proteomes
Shevchenko, A., Tomas, H., Havli, J., Olsen, J. V., & Mann, M. (2006) · Nature Protocols · doi:10.1038/nprot.2006.468 · Cited by 4,942
Self-citationGlobal, In Vivo, and Site-Specific Phosphorylation Dynamics in Signaling Networks
Olsen, J. V., Blagoev, B., Gnad, F., Macek, B., Kumar, C., Mortensen, P., & Mann, M. (2006) · Cell · doi:10.1016/j.cell.2006.09.026 · Cited by 3,499
Self-citation
Metadata
- Authors
- Olsen, J. V., & Mann, M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2004-09-03
- Volume
- 101
- Issue
- 37
- Pages
- 13417-13422
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2062049401
- Cited by
- 313
- References
- 28
- FWCI
- 14.09
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.