In situ measurement of solute transport in the bone lacunar-canalicular system
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Solute transport through the bone lacunar-canalicular system is believed to be essential for osteocyte survival and function but has proved difficult to measure. We report an approach that permits direct measurement of real-time solute movement in intact bones. By using fluorescence recovery after photobleaching, the movement of a vitally injected fluorescent dye (sodium fluorescein) among individual osteocytic lacunae was visualized in situ beneath the periosteal surface of mouse cortical bone at depths up to 50 μm with laser scanning confocal microscopy. Transport was analyzed by using a two-compartment mathematical model of solute diffusion that accounted for the characteristic anatomical features of the lacunar-canalicular system. The diffusion coefficient of fluorescein (376 Da) was determined to be 3.3 ± 0.6 × 10 -6 cm 2 /sec, which is 62% of its diffusion coefficient in water and is similar to diffusion coefficients measured for comparably sized molecules in cartilage. The diffusion of fluorescein in bone is also consistent with the presence of an osteocyte pericellular matrix whose structure resembles that proposed for the endothelial glycocalyx [Squire, J. M., Chew, M., Nneji, G., Neal, C., Barry, J. & Michel, C. (2001) J. Struct. Biol. 136, 239–255]. To our knowledge, this is the first instance where the dynamics of molecular movement has been measured directly in the bone lacunar-canalicular system. This in situ imaging approach should also facilitate the analysis of convection-based transport mechanisms in bones of living animals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Verborgt, O., Tatton, N. A., Majeska, R. J., & Schaffler, M. B. (2002) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2002.17.5.907 · Cited by 192
Self-citation
Cited by
Mechanosensation and transduction in osteocytes
Klein-Nulend, J., Bakker, A. D., Bacabac, R. G., Vatsa, A., & Weinbaum, S. (2013) · Bone · doi:10.1016/j.bone.2012.10.013 · Cited by 528
“[39] have developed a novel technique that combines fluorescence recovery after photobleaching (FRAP) with confocal microscopy to directly measure real time solute movement in intact bones.”
MethodSelf-citationOsteocytes: master orchestrators of bone
Schaffler, M. B., Cheung, W.-Y., Majeska, R., & Kennedy, O. (2014) · Calcified Tissue International · doi:10.1007/s00223-013-9790-y · Cited by 514
Self-citationPrimary cilia mediate mechanosensing in bone cells by a calcium-independent mechanism
Malone, A. M. D., Anderson, C. T., Tummala, P., Kwon, R. Y., Johnston, T. R., Stearns, T., & Jacobs, C. R. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0700636104 · Cited by 477
Boning up on Wolff's Law: Mechanical regulation of the cells that make and maintain bone
Chen, J.-H., Liu, C., You, L., & Simmons, C. A. (2010) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2009.09.016 · Cited by 422
Scaffold Design and Manufacturing: From Concept to Clinic
Hollister, S. J. (2009) · Advanced Materials · doi:10.1002/adma.200802977 · Cited by 408
Fluid and Solute Transport in Bone: Flow-Induced Mechanotransduction
Fritton, S. P., & Weinbaum, S. (2009) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.010908.165136 · Cited by 380
Self-citationArchitecture of the osteocyte network correlates with bone material quality
Kerschnitzki, M., Kollmannsberger, P., Burghammer, M., Duda, G. N., Weinkamer, R., Wagermaier, W., & Fratzl, P. (2013) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.1927 · Cited by 359
Quantifying the osteocyte network in the human skeleton
Buenzli, P. R., & Sims, N. A. (2015) · Bone · doi:10.1016/j.bone.2015.02.016 · Cited by 300
Mechanosensation and transduction in osteocytes
Bonewald, L. F. (2006) · BoneKEy-Osteovision · doi:10.1138/20060233 · Cited by 283
Price, C., Zhou, X., Li, W., & Wang, L. (2011) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.211 · Cited by 279
Self-citationWeinstein, R. S., Wan, C., Liu, Q., Wang, Y., Almeida, M., O’Brien, C. A., Thostenson, J., Roberson, P. K., Boskey, A. L., Clemens, T. L., et al. (2010) · Aging Cell · doi:10.1111/j.1474-9726.2009.00545.x · Cited by 276
Self-citationOsteocyte apoptosis and control of bone resorption following ovariectomy in mice
Emerton, K. B., Hu, B., Woo, A. A., Sinofsky, A., Hernandez, C., Majeska, R. J., Jepsen, K. J., & Schaffler, M. B. (2010) · Bone · doi:10.1016/j.bone.2009.11.006 · Cited by 220
“In bone, movement of such cellular debris from damage sites to bone surfaces, where osteoclasts first form, would be limited by the low permeability of the lacuna-canalicular system to movement of large solutes [53;54].”
BackgroundSelf-citationKitase, Y., Barragan, L., Qing, H., Kondoh, S., Jiang, J. X., Johnson, M. L., & Bonewald, L. F. (2010) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.168 · Cited by 202
“In addition to maintaining osteocyte viability, movement of the bone fluid most likely induces shear stress on the cell membrane of the cell body and along the dendritic process traveling through canaliculi.((44)) This shear stress is thought to be the means whereby the cells sense load on the skeleton.”
BackgroundOsteocyte Mechanobiology and Pericellular Mechanics
Jacobs, C. R., Temiyasathit, S., & Castillo, A. B. (2010) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-070909-105302 · Cited by 197
Morrell, A. E., Brown, G. N., Robinson, S. T., Sattler, R. L., Baik, A. D., Zhen, G., Cao, X., Bonewald, L. F., Jin, W., Kam, L. C., et al. (2018) · Bone Research · doi:10.1038/s41413-018-0007-x · Cited by 184
Fluid flow in the osteocyte mechanical environment: a fluid–structure interaction approach
Verbruggen, S. W., Vaughan, T. J., & McNamara, L. M. (2014) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-013-0487-y · Cited by 174
“08 μm, based on experimental measurements of the geometry of the osteocyte environment (McNamara et al. 2009; Wang et al. 2005; You et al. 2004).”
BackgroundTowards quantitative 3D imaging of the osteocyte lacuno-canalicular network
Schneider, P., Meier, M., Wepf, R., & Müller, R. (2010) · Bone · doi:10.1016/j.bone.2010.07.026 · Cited by 172
“Similar to morphometric measures for osteocyte lacunae, the quantitative assessment of the canalicular system has essentially been based on 2D methods to date and provided measurements of the canalicular density [40,50,58,78], the canalicular diameter [42], and the geometry of the pericellular space [24].”
BackgroundMethodVerbruggen, S. W., Vaughan, T. J., & McNamara, L. M. (2012) · Journal of The Royal Society Interface · doi:10.1098/rsif.2012.0286 · Cited by 159
Herman, B. C., Cardoso, L., Majeska, R. J., Jepsen, K. J., & Schaffler, M. B. (2010) · Bone · doi:10.1016/j.bone.2010.07.006 · Cited by 159
“Under isoflurane anesthesia (1–3%), right ulnae were subjected to fatigue loading in end-load bending via the olecranon and flexed carpus as previously described [3,15,76,77].”
MethodSelf-citationKennedy, O. D., Laudier, D. M., Majeska, R. J., Sun, H. B., & Schaffler, M. B. (2014) · Bone · doi:10.1016/j.bone.2014.03.049 · Cited by 151
“Apoptotic bodies are ~20–1000 nm in diameter, while the sieving properties of the pericellular matrix surrounding osteocyte processes only permit movement of solutes of less than 70 kDa (≈6 nm diameter) [42, 43].”
BackgroundSelf-citationJähn, K., Kelkar, S., Zhao, H., Xie, Y., Tiede-Lewis, L. M., Dusevich, V., Dallas, S. L., & Bonewald, L. F. (2017) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.3167 · Cited by 116
“Assuming an estimated lacuno-canalicular fluid volume (estimations based on unpublished data and((20,21))) of 100mm(3) (ie, 10 L) this would equate to a molar concentration of Hþ ions in the lacuno-canalicular fluid of 6.”
Xie, W., Dolder, S., Siegrist, M., Wetterwald, A., & Hofstetter, W. (2016) · Calcified Tissue International · doi:10.1007/s00223-016-0129-3 · Cited by 12
Metadata
- Authors
- Wang, L., Wang, Y., Han, Y., Henderson, S. C., Majeska, R. J., Weinbaum, S., & Schaffler, M. B.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2005-08-08
- Volume
- 102
- Issue
- 33
- Pages
- 11911-11916
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1973670265
- Cited by
- 213
- References
- 1
- FWCI
- 2.07
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.