Strain amplification in bone mechanobiology: a computational investigation of the in vivo mechanics of osteocytes
Open accessThe DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Abstract
The osteocyte is believed to act as the main sensor of mechanical stimulus in bone, controlling signalling for bone growth and resorption in response to changes in the mechanical demands placed on our bones throughout life. However, the precise mechanical stimuli that bone cells experience in vivo are not yet fully understood. The objective of this study is to use computational methods to predict the loading conditions experienced by osteocytes during normal physiological activities. Confocal imaging of the lacunar–canalicular network was used to develop three-dimensional finite element models of osteocytes, including their cell body, and the surrounding pericellular matrix (PCM) and extracellular matrix (ECM). We investigated the role of the PCM and ECM projections for amplifying mechanical stimulation to the cells. At loading levels, representing vigorous physiological activity (3000 µɛ), our results provide direct evidence that (i) confocal image-derived models predict 350–400% greater strain amplification experienced by osteocytes compared with an idealized cell, (ii) the PCM increases the cell volume stimulated more than 3500 µɛ by 4–10% and (iii) ECM projections amplify strain to the cell by approximately 50–420%. These are the first confocal image-derived computational models to predict osteocyte strain in vivo and provide an insight into the mechanobiology of the osteocyte.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
“Whither flows the fluid in bone?” An osteocyte's perspective
Knothe Tate, M. L. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00123-4 · Cited by 309
Molecular and cellular biology of alveolar bone
SODEK, J., & MCKEE, M. D. (2000) · Periodontology 2000 · doi:10.1034/j.1600-0757.2000.2240106.x · Cited by 283 · cited 1×
“1993), 8 which is present in abundance along the canalicular wall (Devoll et al. 1997; McKee and 9 Nanci 1996; Noda et al. 2003; Sodek and McKee 2000).”
BackgroundA model for the role of integrins in flow induced mechanotransduction in osteocytes
Wang, Y., McNamara, L. M., Schaffler, M. B., & Weinbaum, S. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0707246104 · Cited by 265
Self-citationAttachment of Osteocyte Cell Processes to the Bone Matrix
McNamara, L. M., Majeska, R. J., Weinbaum, S., Friedrich, V., & Schaffler, M. B. (2009) · The Anatomical Record · doi:10.1002/ar.20869 · Cited by 212
Self-citation
Cited by
Mechanical stimulation modulates osteocyte regulation of cancer cell phenotype
Verbruggen, S. W., Thompson, C. L., Duffy, M. P., Lunetto, S., Nolan, J., Pearce, O. M. T., Jacobs, C. R., & Knight, M. M. (2021) · Cancers · doi:10.3390/cancers13122906 · Cited by 44
Metadata
- Authors
- Verbruggen, S. W., Vaughan, T. J., & McNamara, L. M.
- Venue
- Journal of The Royal Society Interface
- Publisher
- The Royal Society
- Published
- 2012-06-06
- Volume
- 9
- Issue
- 75
- Pages
- 2735-2744
- ISSN
- 1742-5662 (ISSN-L)
- 1742-5689
- OpenAlex
- W2146614596
- Cited by
- 159
- References
- 4
- FWCI
- 4.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Strain amplification in bone mechanobiology: a computational investigation of the in vivo mechanics of osteocytes. https://app.cochat.ai/papers/10.1098/rsif.2012.0286
- The paper
- Verbruggen, S. W., Vaughan, T. J., & McNamara, L. M. (2012). Strain amplification in bone mechanobiology: a computational investigation of the in vivo mechanics of osteocytes. Journal of The Royal Society Interface. https://doi.org/10.1098/rsif.2012.0286
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.