The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Beyond Rayleigh's criterion: A resolution measure with application to single-molecule microscopy
Abstract
Rayleigh's criterion is extensively used in optical microscopy for determining the resolution of microscopes. This criterion imposes a resolution limit that has long been held as an impediment for studying nanoscale biological phenomenon through an optical microscope. However, it is well known that Rayleigh's criterion is based on intuitive notions. For example, Rayleigh's criterion is formulated in a deterministic setting that neglects the photon statistics of the acquired data. Hence it does not take into account the number of detected photons, which, in turn, raises concern over the use of Rayleigh's criterion in photon-counting techniques such as single-molecule microscopy. Here, we re-examine the resolution problem by adopting a stochastic framework and present a resolution measure that overcomes the limitations of Rayleigh's criterion. This resolution measure predicts that the resolution of optical microscopes is not limited and that it can be improved by increasing the number of detected photons. Experimental verification of the resolution measure is carried out by imaging single-molecule pairs with different distances of separation. The resolution measure provides a quantitative tool for designing and evaluating single-molecule experiments that probe biomolecular interactions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Inoué, S., & Spring, K. R. (1997) · doi:10.1007/978-1-4615-5859-0 · Cited by 326
Cited by
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Subdiffraction‐Resolution Fluorescence Imaging with Conventional Fluorescent Probes
Heilemann, M., van de Linde, S., Schüttpelz, M., Kasper, R., Seefeldt, B., Mukherjee, A., Tinnefeld, P., & Sauer, M. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200802376 · Cited by 1,866
Single-molecule localization microscopy
Lelek, M., Gyparaki, M. T., Beliu, G., Schueder, F., Griffié, J., Manley, S., Jungmann, R., Sauer, M., Lakadamyali, M., & Zimmer, C. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00038-x · Cited by 954
Advances in photonic quantum sensing
Pirandola, S., Bardhan, B. R., Gehring, T., Weedbrook, C., & Lloyd, S. (2018) · Nature Photonics · doi:10.1038/s41566-018-0301-6 · Cited by 804
Measuring image resolution in optical nanoscopy
Nieuwenhuizen, R. P. J., Lidke, K. A., Bates, M., Puig, D. L., Grünwald, D., Stallinga, S., & Rieger, B. (2013) · Nature Methods · doi:10.1038/nmeth.2448 · Cited by 800
Metadata
- Authors
- Ram, S., Ward, E. S., & Ober, R. J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2006-03
- Volume
- 103
- Issue
- 12
- Pages
- 4457-4462
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2165994754
- Cited by
- 259
- References
- 2
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Beyond Rayleigh's criterion: A resolution measure with application to single-molecule microscopy. https://app.cochat.ai/papers/10.1073/pnas.0508047103
- The paper
- Ram, S., Ward, E. S., & Ober, R. J. (2006). Beyond Rayleigh's criterion: A resolution measure with application to single-molecule microscopy. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0508047103
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.