The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Thermal fluctuations of grafted microtubules provide evidence of a length-dependent persistence length
Open accessAbstract
Microtubules are hollow cylindrical structures that constitute one of the three major classes of cytoskeletal filaments. On the mesoscopic length scale of a cell, their material properties are characterized by a single stiffness parameter, the persistence length ℓ p . Its value, in general, depends on the microscopic interactions between the constituent tubulin dimers and the architecture of the microtubule. Here, we use single-particle tracking methods combined with a fluctuation analysis to systematically study the dependence of ℓ p on the total filament length L . Microtubules are grafted to a substrate with one end free to fluctuate in three dimensions. A fluorescent bead is attached proximally to the free tip and is used to record the thermal fluctuations of the microtubule's end. The position distribution functions obtained with this assay allow the precise measurement of ℓ p for microtubules of different contour length L . Upon varying L between 2.6 and 47.5 μm, we find a systematic increase of ℓ p from 110 to 5,035 μm. At the same time we verify that, for a given filament length, the persistence length is constant over the filament within the experimental accuracy. We interpret this length dependence as a consequence of a nonnegligible shear deflection determined by subnanometer relative displacement of adjacent protofilaments. Our results may shine new light on the function of microtubules as sophisticated nanometer-sized molecular machines and give a unified explanation of seemingly uncorrelated spreading of microtubules' stiffness previously reported in literature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
VMD: visual molecular dynamics
Humphrey, W., Dalke, A., & Schulten, K. (1996) · Journal of Molecular Graphics · doi:10.1016/0263-7855(96)00018-5 · Cited by 66,952
Cited by
Kasza, K. E., Rowat, A. C., Liu, J., Angelini, T. E., Brangwynne, C. P., Koenderink, G. H., & Weitz, D. A. (2007) · Current Opinion in Cell Biology · doi:10.1016/j.ceb.2006.12.002 · Cited by 445
Microtubules self-repair in response to mechanical stress
Schaedel, L., John, K., Gaillard, J., Nachury, M. V., Blanchoin, L., & Théry, M. (2015) · Nature Materials · doi:10.1038/nmat4396 · Cited by 294
Microtubule curvatures under perpendicular electric forces reveal a low persistence length
Van den Heuvel, M. G. L., de Graaff, M. P., & Dekker, C. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0704169105 · Cited by 88
Microtubule lattice plasticity
Cross, R. A. (2019) · Current Opinion in Cell Biology · doi:10.1016/j.ceb.2018.10.004 · Cited by 43
Protein design of two-component tubular assemblies similar to cytoskeletons
Noji, M., Sugita, Y., Yamazaki, Y., Miyazaki, M., & Suzuki, Y. (2025) · Nature Communications · doi:10.1038/s41467-025-62076-3 · Cited by 3
Metadata
- Authors
- Pampaloni, F., Lattanzi, G., Jonáš, A., Surrey, T., Frey, E., & Florin, E.-L.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2006-07-05
- Volume
- 103
- Issue
- 27
- Pages
- 10248-10253
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2158029007
- Cited by
- 358
- References
- 1
- FWCI
- 9.36
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Thermal fluctuations of grafted microtubules provide evidence of a length-dependent persistence length. https://app.cochat.ai/papers/10.1073/pnas.0603931103
- The paper
- Pampaloni, F., Lattanzi, G., Jonáš, A., Surrey, T., Frey, E., & Florin, E.-L. (2006). Thermal fluctuations of grafted microtubules provide evidence of a length-dependent persistence length. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0603931103
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.