The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Adaptive wavefront correction in two-photon microscopy using coherence-gated wavefront sensing
Open accessAbstract
The image quality of a two-photon microscope is often degraded by wavefront aberrations induced by the specimen. We demonstrate here that resolution and signal size in two-photon microcopy can be substantially improved, even in living biological specimens, by adaptive wavefront correction based on sensing the wavefront of coherence-gated backscattered light (coherence-gated wavefront sensing, CGWS) and wavefront control by a deformable mirror. A nearly diffraction-limited focus can be restored even for strong aberrations. CGWS-based wavefront correction should be applicable to samples with a wide range of scattering properties and it should be possible to perform real-time pixel-by-pixel correction even at fast scan speeds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Self-citationThe zebrafish book : a guide for the laboratory use of zebrafish (Danio rerio)
Westerfield, M. (1995) · Medical Entomology and Zoology · Cited by 6,813
Diffuse radiation in the Galaxy
Henyey, L. C., & Greenstein, J. L. (1941) · The Astrophysical Journal · doi:10.1086/144246 · Cited by 2,913
Zernike polynomials and atmospheric turbulence*
Noll, R. J. (1976) · Journal of the Optical Society of America · doi:10.1364/josa.66.000207 · Cited by 2,771
Gustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
(2007) · Wiley eBooks · doi:10.1002/9780470135976 · Cited by 2,092
Method of obtaining optical sectioning by using structured light in a conventional microscope
Neil, M. A. A., Juškaitis, R., & Wilson, T. (1997) · Optics Letters · doi:10.1364/ol.22.001905 · Cited by 1,143
Hell, S. W. (2003) · Nature Biotechnology · doi:10.1038/nbt895 · Cited by 1,003
Speckle in Optical Coherence Tomography
Schmitt, J. M., Xiang, S. H., & Yung, K. M. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429925 · Cited by 837
Cited by
Grienberger, C., & Konnerth, A. (2012) · Neuron · doi:10.1016/j.neuron.2012.02.011 · Cited by 1,354
Guidestar-assisted wavefront-shaping methods for focusing light into biological tissue
Horstmeyer, R., Ruan, H., & Yang, C. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.140 · Cited by 651
Adaptive optics via pupil segmentation for high-resolution imaging in biological tissues
Ji, N., Milkie, D. E., & Betzig, E. (2010) · Nature Methods · doi:10.1038/nmeth.1411 · Cited by 585
Looking around corners and through thin turbid layers in real time with scattered incoherent light
Katz, O., Small, E., & Silberberg, Y. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.150 · Cited by 564
Adaptive optical fluorescence microscopy
Ji, N. (2017) · Nature Methods · doi:10.1038/nmeth.4218 · Cited by 527
Metadata
- Authors
- Rueckel, M., Mack-Bucher, J. A., & Denk, W.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2006-11-14
- Volume
- 103
- Issue
- 46
- Pages
- 17137-17142
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2079416564
- Cited by
- 307
- References
- 23
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Adaptive wavefront correction in two-photon microscopy using coherence-gated wavefront sensing. https://app.cochat.ai/papers/10.1073/pnas.0604791103
- The paper
- Rueckel, M., Mack-Bucher, J. A., & Denk, W. (2006). Adaptive wavefront correction in two-photon microscopy using coherence-gated wavefront sensing. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0604791103
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.