Adaptive wavefront correction in two-photon microscopy using coherence-gated wavefront sensing
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
The image quality of a two-photon microscope is often degraded by wavefront aberrations induced by the specimen. We demonstrate here that resolution and signal size in two-photon microcopy can be substantially improved, even in living biological specimens, by adaptive wavefront correction based on sensing the wavefront of coherence-gated backscattered light (coherence-gated wavefront sensing, CGWS) and wavefront control by a deformable mirror. A nearly diffraction-limited focus can be restored even for strong aberrations. CGWS-based wavefront correction should be applicable to samples with a wide range of scattering properties and it should be possible to perform real-time pixel-by-pixel correction even at fast scan speeds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of Optics: 60th Anniversary Edition
Born, M., & Wolf, E. (2019) · Cambridge University Press eBooks · doi:10.1017/9781108769914 · Cited by 26,251
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Self-citationThe zebrafish book : a guide for the laboratory use of zebrafish (Danio rerio)
Westerfield, M. (1995) · Medical Entomology and Zoology · Cited by 6,813
Diffuse radiation in the Galaxy
Henyey, L. C., & Greenstein, J. L. (1941) · The Astrophysical Journal · doi:10.1086/144246 · Cited by 2,913
Zernike polynomials and atmospheric turbulence*
Noll, R. J. (1976) · Journal of the Optical Society of America · doi:10.1364/josa.66.000207 · Cited by 2,771
Gustafsson, M. G. L. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0406877102 · Cited by 2,224
(2007) · Wiley eBooks · doi:10.1002/9780470135976 · Cited by 2,092
Method of obtaining optical sectioning by using structured light in a conventional microscope
Neil, M. A. A., Juškaitis, R., & Wilson, T. (1997) · Optics Letters · doi:10.1364/ol.22.001905 · Cited by 1,143
Hell, S. W. (2003) · Nature Biotechnology · doi:10.1038/nbt895 · Cited by 1,003
Speckle in Optical Coherence Tomography
Schmitt, J. M., Xiang, S. H., & Yung, K. M. (1999) · Journal of Biomedical Optics · doi:10.1117/1.429925 · Cited by 837
Cited by
Grienberger, C., & Konnerth, A. (2012) · Neuron · doi:10.1016/j.neuron.2012.02.011 · Cited by 1,354
Guidestar-assisted wavefront-shaping methods for focusing light into biological tissue
Horstmeyer, R., Ruan, H., & Yang, C. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.140 · Cited by 651
Adaptive optics via pupil segmentation for high-resolution imaging in biological tissues
Ji, N., Milkie, D. E., & Betzig, E. (2010) · Nature Methods · doi:10.1038/nmeth.1411 · Cited by 585
Looking around corners and through thin turbid layers in real time with scattered incoherent light
Katz, O., Small, E., & Silberberg, Y. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.150 · Cited by 564
Adaptive optical fluorescence microscopy
Ji, N. (2017) · Nature Methods · doi:10.1038/nmeth.4218 · Cited by 527
Focusing and compression of ultrashort pulses through scattering media
Katz, O., Small, E., Bromberg, Y., & Silberberg, Y. (2011) · Nature Photonics · doi:10.1038/nphoton.2011.72 · Cited by 496
Pittet, M. J., & Weissleder, R. (2011) · Cell · doi:10.1016/j.cell.2011.11.004 · Cited by 466
“Promising efforts to improve penetration depth include the use of far-red probes and longer wavelength lasers (Andresen et al., 2009; Condeelis and Weissleder, 2010), and/or adaptive optics (Rueckel et al., 2006).”
Second Harmonic Generation Imaging Microscopy: Applications to Diseases Diagnostics
Campagnola, P. (2011) · Analytical Chemistry · doi:10.1021/ac1032325 · Cited by 410
The Big and the Small: Challenges of Imaging the Brain’s Circuits
Lichtman, J. W., & Denk, W. (2011) · Science · doi:10.1126/science.1209168 · Cited by 370
Self-citationImaging in vivo: watching the brain in action
Kerr, J. N. D., & Denk, W. (2008) · Nature Reviews Neuroscience · doi:10.1038/nrn2338 · Cited by 346
Self-citationAdaptive optics enables 3D STED microscopy in aberrating specimens
Gould, T. J., Burke, D., Bewersdorf, J., & Booth, M. J. (2012) · Optics Express · doi:10.1364/oe.20.020998 · Cited by 315
Direct wavefront sensing for high-resolution in vivo imaging in scattering tissue
Wang, K., Sun, W., Richie, C. T., Harvey, B. K., Betzig, E., & Ji, N. (2015) · Nature Communications · doi:10.1038/ncomms8276 · Cited by 292
Fluctuating and sensory-induced vasodynamics in rodent cortex extend arteriole capacity
Drew, P. J., Shih, A. Y., & Kleinfeld, D. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1100428108 · Cited by 287
Kim, M., Choi, Y., Yoon, C., Choi, W., Kim, J., Park, Q.-H., & Choi, W. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.159 · Cited by 286
Advances in Light Microscopy for Neuroscience
Wilt, B. A., Burns, L. D., Wei Ho, E. T., Ghosh, K. K., Mukamel, E. A., & Schnitzer, M. J. (2009) · Annual Review of Neuroscience · doi:10.1146/annurev.neuro.051508.135540 · Cited by 278
Control of Light Transmission through Opaque Scattering Media in Space and Time
Aulbach, J., Gjonaj, B., Johnson, P. M., Mosk, A. P., & Lagendijk, A. (2011) · Physical Review Letters · doi:10.1103/physrevlett.106.103901 · Cited by 269
Digital phase conjugation of second harmonic radiation emitted by nanoparticles in turbid media
Hsieh, C.-L., Pu, Y., Grange, R., & Psaltis, D. (2010) · Optics Express · doi:10.1364/oe.18.012283 · Cited by 199
Ji, N., Sato, T. R., & Betzig, E. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1109202108 · Cited by 192
Binding, J., Ben Arous, J., Léger, J.-F., Gigan, S., Boccara, C., & Bourdieu, L. (2011) · Optics Express · doi:10.1364/oe.19.004833 · Cited by 173
Review of optical coherence tomography in oncology
Wang, J., Xu, Y., & Boppart, S. A. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.12.121711 · Cited by 172
“Hardware-based adaptive optics 181 and coherence-gated sensor-less adaptive optics 182 have been developed for optical aberration compensation.”
BackgroundMultiphoton fluorescence microscopy for in vivo imaging
Xu, C., Nedergaard, M., Fowell, D. J., Friedl, P., & Ji, N. (2024) · Cell · doi:10.1016/j.cell.2024.07.036 · Cited by 165
Two-Photon Microscopy: Shedding Light on the Chemistry of Vision
Imanishi, Y., Lodowski, K. H., & Koutalos, Y. (2007) · Biochemistry · doi:10.1021/bi701055g · Cited by 58
Two-Photon Imaging of Microglia in the Mouse Cortex In Vivo
Nimmerjahn, A. (2012) · Cold Spring Harbor Protocols · doi:10.1101/pdb.prot069294 · Cited by 38
“…optics (Oheim et al. 2001), dispersion precompen-sation (Tang et al. 2006), supplementary fi ber-optic light collection (Engelbrecht et al. 2009), passive pulse splitting (Ji et al. 2008), bunched pulse excitation (Donnert et al. 2009), or adaptive wave-front correction (Rueckel et al. 2006).”
InfluentialIntravital microscopy for real-time monitoring of drug delivery and nanobiological processes
Momoh, J., Kapsokalyvas, D., Vogt, M., Hak, S., Kiessling, F., van Zandvoort, M., Lammers, T., & Sofias, A. M. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114528 · Cited by 33
Adaptive Optical Two-Photon Microscopy for Surface-Profiled Living Biological Specimens
Yamaguchi, K., Otomo, K., Kozawa, Y., Tsutsumi, M., Inose, T., Hirai, K., Sato, S., Nemoto, T., & Uji-i, H. (2021) · ACS Omega · doi:10.1021/acsomega.0c04888 · Cited by 19
Visualization of Retinoid Storage and Trafficking by Two-Photon Microscopy
Imanishi, Y., & Palczewski, K. (2010) · Methods in Molecular Biology · doi:10.1007/978-1-60327-325-1_14 · Cited by 16
Metadata
- Authors
- Rueckel, M., Mack-Bucher, J. A., & Denk, W.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2006-11-14
- Volume
- 103
- Issue
- 46
- Pages
- 17137-17142
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2079416564
- Cited by
- 307
- References
- 23
- FWCI
- 7.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.