CoChat

Importance of dosage standardization for interpreting transcriptomal signature profiles: Evidence from studies of xenoestrogens

Shioda, Toshi, Chesnes, Jessica, Coser, Kathryn R., Zou, Lihua, Hur, Jingyung, Dean, Kathleen L., Sonnenschein, Carlos, Soto, Ana M., Isselbacher, Kurt J. · 2006 · Proceedings of the National Academy of Sciences
Cited by 68

The DOI matches its Crossref record.

Abstract

To obtain insights into similarities and differences in the biological actions of related drugs or toxic agents, their transcriptomal signature profiles (TSPs) have been examined in a large number of studies. However, many such reports did not provide proper justification for the dosage criteria of each agent. Using a well characterized cell culture model of estrogen-dependent proliferation of MCF7 human breast cancer cells, we demonstrate how different approaches to dosage standardization exert critical influences on TSPs, leading to different and even conflicting conclusions. Using quantitative cellular response (QCR)-based dosage criteria, TSPs were determined by Affymetrix microarray when cells were proliferating at comparable rates in the presence of various estrogens. We observed that TSPs of the xenoestrogens (e.g., genistein or bisphenol A) were clearly different from the TSP of 17β-estradiol; namely, the former strongly enhanced expression of genes involved in mitochondrial oxidative phosphorylation, whereas the latter showed minimal effects. In contrast, TSPs for genistein and 17β-estradiol were indistinguishable by using the marker gene expression-based dosage criteria, conditions in which there was comparable expression of the mRNA transcripts for the estrogen-inducible WISP2 gene. Our findings indicate that determination and interpretation of TSPs in pharmacogenomic and toxicogenomic studies that examine the transcriptomal actions of related agents by microarray require a clear rationale for the dosage standardization method to be used. We suggest that future studies involving TSP analyses use quantitative and objective dosage standardization methods, such as those with quantitative cellular response or marker gene expression-based dosage criteria.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1073/pnas.0605341103

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 68

Metadata

Authors
Shioda, T., Chesnes, J., Coser, K. R., Zou, L., Hur, J., Dean, K. L., Sonnenschein, C., Soto, A. M., & Isselbacher, K. J.
Venue
Proceedings of the National Academy of Sciences
Published
2006-08-08
Volume
103
Issue
32
Pages
12033-12038
ISSN
  • 0027-8424 (ISSN-L)
  • 1091-6490
OpenAlex
W1967256854
Cited by
68
References
0
FWCI
3.89
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Importance of dosage standardization for interpreting transcriptomal signature profiles: Evidence from studies of xenoestrogens. https://app.cochat.ai/papers/10.1073/pnas.0605341103
The paper
Shioda, T., Chesnes, J., Coser, K. R., Zou, L., Hur, J., Dean, K. L., Sonnenschein, C., Soto, A. M., & Isselbacher, K. J. (2006). Importance of dosage standardization for interpreting transcriptomal signature profiles: Evidence from studies of xenoestrogens. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0605341103

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.