The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Magnetic resonance imaging with an optical atomic magnetometer
Open accessAbstract
We report an approach for the detection of magnetic resonance imaging without superconducting magnets and cryogenics: optical atomic magnetometry. This technique possesses a high sensitivity independent of the strength of the static magnetic field, extending the applicability of magnetic resonance imaging to low magnetic fields and eliminating imaging artifacts associated with high fields. By coupling with a remote-detection scheme, thereby improving the filling factor of the sample, we obtained time-resolved flow images of water with a temporal resolution of 0.1 s and spatial resolutions of 1.6 mm perpendicular to the flow and 4.5 mm along the flow. Potentially inexpensive, compact, and mobile, our technique provides a viable alternative for MRI detection with substantially enhanced sensitivity and time resolution for various situations where traditional MRI is not optimal.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A subfemtotesla multichannel atomic magnetometer
Kominis, I. K., Kornack, T. W., Allred, J. C., & Romalis, M. V. (2003) · Nature · doi:10.1038/nature01484 · Cited by 1,631
Cited by
Budker, D., & Romalis, M. (2007) · Nature Physics · doi:10.1038/nphys566 · Cited by 1,916
Self-citationTemperature Dependence of the Nitrogen-Vacancy Magnetic Resonance in Diamond
Acosta, V. M., Bauch, E., Ledbetter, M. P., Waxman, A., Bouchard, L.-S., & Budker, D. (2010) · Physical Review Letters · doi:10.1103/physrevlett.104.070801 · Cited by 735
Self-citationQuantum sensors for biomedical applications
Aslam, N., Zhou, H., Urbach, E. K., Turner, M. J., Walsworth, R. L., Lukin, M. D., & Park, H. (2023) · Nature Reviews Physics · doi:10.1038/s42254-023-00558-3 · Cited by 527
Subpicotesla atomic magnetometry with a microfabricated vapour cell
Shah, V., Knappe, S., Schwindt, P. D. D., & Kitching, J. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.201 · Cited by 415
Spin-exchange-relaxation-free magnetometry with Cs vapor
Ledbetter, M. P., Savukov, I. M., Acosta, V. M., Budker, D., & Romalis, M. V. (2008) · Physical Review A · doi:10.1103/physreva.77.033408 · Cited by 399
Self-citation
Metadata
- Authors
- Xu, S., Yashchuk, V. V., Donaldson, M. H., Rochester, S. M., Budker, D., & Pines, A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2006-08-22
- Volume
- 103
- Issue
- 34
- Pages
- 12668-12671
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1593146420
- Cited by
- 168
- References
- 1
- FWCI
- 7.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.