The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
A single-molecule barcoding system using nanoslits for DNA analysis
Open accessAbstract
Molecular confinement offers new routes for arraying large DNA molecules, enabling single-molecule schemes aimed at the acquisition of sequence information. Such schemes can rapidly advance to become platforms capable of genome analysis if elements of a nascent system can be integrated at an early stage of development. Integrated strategies are needed for surmounting the stringent experimental requirements of nanoscale devices regarding fabrication, sample loading, biochemical labeling, and detection. We demonstrate that disposable devices featuring both micro- and nanoscale features can greatly elongate DNA molecules when buffer conditions are controlled to alter DNA stiffness. Furthermore, we present analytical calculations that describe this elongation. We also developed a complementary enzymatic labeling scheme that tags specific sequences on elongated molecules within described nanoslit devices that are imaged via fluorescence resonance energy transfer. Collectively, these developments enable scaleable molecular confinement approaches for genome analysis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Genome sequencing in microfabricated high-density picolitre reactors
Margulies, M., Egholm, M., Altman, W. E., Attiya, S., Bader, J. S., Bemben, L. A., Berka, J., Braverman, M. S., Chen, Y.-J., Chen, Z., et al. (2005) · Nature · doi:10.1038/nature03959 · Cited by 7,693
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Imprint of sub-25 nm vias and trenches in polymers
Chou, S. Y., Krauss, P. R., & Renstrom, P. J. (1995) · Applied Physics Letters · doi:10.1063/1.114851 · Cited by 2,706
Soft Lithography in Biology and Biochemistry
Whitesides, G. M., Ostuni, E., Takayama, S., Jiang, X., & Ingber, D. E. (2001) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.3.1.335 · Cited by 2,607
Genome sequence of enterohaemorrhagic Escherichia coli O157:H7
Perna, N. T., Plunkett, G., Burland, V., Mau, B., Glasner, J. D., Rose, D. J., Mayhew, G. F., Evans, P. S., Gregor, J., Kirkpatrick, H. A., et al. (2001) · Nature · doi:10.1038/35054089 · Cited by 2,055
Self-citationThe Genome of the Diatom Thalassiosira Pseudonana : Ecology, Evolution, and Metabolism
Armbrust, E. V., Berges, J. A., Bowler, C., Green, B. R., Martinez, D., Putnam, N. H., Zhou, S., Allen, A. E., Apt, K. E., Bechner, M., et al. (2004) · Science · doi:10.1126/science.1101156 · Cited by 2,010
Self-citationAccurate Multiplex Polony Sequencing of an Evolved Bacterial Genome
Shendure, J., Porreca, G. J., Reppas, N. B., Lin, X., McCutcheon, J. P., Rosenbaum, A. M., Wang, M. D., Zhang, K., Mitra, R. D., & Church, G. M. (2005) · Science · doi:10.1126/science.1117389 · Cited by 1,402
Ionic effects on the elasticity of single DNA molecules
Baumann, C. G., Smith, S. B., Bloomfield, V. A., & Bustamante, C. (1997) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.94.12.6185 · Cited by 1,001
Electrostatic Persistence Length of a Wormlike Polyelectrolyte
Skolnick, J., & Fixman, M. (1977) · Macromolecules · doi:10.1021/ma60059a011 · Cited by 857
Polyelectrolytes near the rod limit
Odijk, T. (1977) · Journal of Polymer Science: Polymer Physics Edition · doi:10.1002/pol.1977.180150307 · Cited by 744
Self-citation
Cited by
Transport phenomena in nanofluidics
Schoch, R. B., Han, J., & Renaud, P. (2008) · Reviews of Modern Physics · doi:10.1103/revmodphys.80.839 · Cited by 1,933
Genome structural variation discovery and genotyping
Alkan, C., Coe, B. P., & Eichler, E. E. (2011) · Nature Reviews Genetics · doi:10.1038/nrg2958 · Cited by 1,630
DNA confinement in nanochannels: physics and biological applications
Reisner, W., Pedersen, J. N., & Austin, R. H. (2012) · Reports on Progress in Physics · doi:10.1088/0034-4885/75/10/106601 · Cited by 336
Jain, K. K. (2017) · Springer eBooks · doi:10.1007/978-1-4939-6966-1 · Cited by 264
Metadata
- Authors
- Jo, K., Dhingra, D. M., Odijk, T., de Pablo, J. J., Graham, M. D., Runnheim, R., Forrest, D., & Schwartz, D. C.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2007-02-20
- Volume
- 104
- Issue
- 8
- Pages
- 2673-2678
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2062900575
- Cited by
- 309
- References
- 28
- FWCI
- 16.92
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: A single-molecule barcoding system using nanoslits for DNA analysis. https://app.cochat.ai/papers/10.1073/pnas.0611151104
- The paper
- Jo, K., Dhingra, D. M., Odijk, T., de Pablo, J. J., Graham, M. D., Runnheim, R., Forrest, D., & Schwartz, D. C. (2007). A single-molecule barcoding system using nanoslits for DNA analysis. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0611151104
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.