The DOI matches its Crossref record.
Simultaneous in vivo positron emission tomography and magnetic resonance imaging
Open accessAbstract
Positron emission tomography (PET) and magnetic resonance imaging (MRI) are widely used in vivo imaging technologies with both clinical and biomedical research applications. The strengths of MRI include high-resolution, high-contrast morphologic imaging of soft tissues; the ability to image physiologic parameters such as diffusion and changes in oxygenation level resulting from neuronal stimulation; and the measurement of metabolites using chemical shift imaging. PET images the distribution of biologically targeted radiotracers with high sensitivity, but images generally lack anatomic context and are of lower spatial resolution. Integration of these technologies permits the acquisition of temporally correlated data showing the distribution of PET radiotracers and MRI contrast agents or MR-detectable metabolites, with registration to the underlying anatomy. An MRI-compatible PET scanner has been built for biomedical research applications that allows data from both modalities to be acquired simultaneously. Experiments demonstrate no effect of the MRI system on the spatial resolution of the PET system and <10% reduction in the fraction of radioactive decay events detected by the PET scanner inside the MRI. The signal-to-noise ratio and uniformity of the MR images, with the exception of one particular pulse sequence, were little affected by the presence of the PET scanner. In vivo simultaneous PET and MRI studies were performed in mice. Proof-of-principle in vivo MR spectroscopy and functional MRI experiments were also demonstrated with the combined scanner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
The role of porphyrin chemistry in tumor imaging and photodynamic therapy
Ethirajan, M., Chen, Y., Joshi, P., & Pandey, R. K. (2011) · Chem. Soc. Rev. · doi:10.1039/b915149b · Cited by 2,034
Modern Diagnostic Imaging Technique Applications and Risk Factors in the Medical Field: A Review
Hussain, S., Mubeen, I., Ullah, N., Shah, S. S. U. D., Khan, B. A., Zahoor, M., Ullah, R., Khan, F. A., & Sultan, M. A. (2022) · BioMed Research International · doi:10.1155/2022/5164970 · Cited by 787
Evidence for brain glial activation in chronic pain patients
Loggia, M. L., Chonde, D. B., Akeju, O., Arabasz, G., Catana, C., Edwards, R. R., Hill, E., Hsu, S., Izquierdo-Garcia, D., Ji, R.-R., et al. (2015) · Brain · doi:10.1093/brain/awu377 · Cited by 503
Self-citationA smart and versatile theranostic nanomedicine platform based on nanoporphyrin
Li, Y., Lin, T.-Y., Luo, Y., Liu, Q., Xiao, W., Guo, W., Lac, D., Zhang, H., Feng, C., Wachsmann-Hogiu, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms5712 · Cited by 414
Self-citationPET/MRI of Inflammation in Myocardial Infarction
Lee, W. W., Marinelli, B., van der Laan, A. M., Sena, B. F., Gorbatov, R., Leuschner, F., Dutta, P., Iwamoto, Y., Ueno, T., Begieneman, M. P. V., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.066 · Cited by 340
Metadata
- Authors
- Catana, C., Procissi, D., Wu, Y., Judenhofer, M. S., Qi, J., Pichler, B. J., Jacobs, R. E., & Cherry, S. R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2008-03-11
- Volume
- 105
- Issue
- 10
- Pages
- 3705-3710
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2092726542
- Cited by
- 272
- References
- 0
- FWCI
- 25.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous in vivo positron emission tomography and magnetic resonance imaging. https://app.cochat.ai/papers/10.1073/pnas.0711622105
- The paper
- Catana, C., Procissi, D., Wu, Y., Judenhofer, M. S., Qi, J., Pichler, B. J., Jacobs, R. E., & Cherry, S. R. (2008). Simultaneous in vivo positron emission tomography and magnetic resonance imaging. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.0711622105
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.