Simultaneous in vivo positron emission tomography and magnetic resonance imaging
Open accessThe DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Abstract
Positron emission tomography (PET) and magnetic resonance imaging (MRI) are widely used in vivo imaging technologies with both clinical and biomedical research applications. The strengths of MRI include high-resolution, high-contrast morphologic imaging of soft tissues; the ability to image physiologic parameters such as diffusion and changes in oxygenation level resulting from neuronal stimulation; and the measurement of metabolites using chemical shift imaging. PET images the distribution of biologically targeted radiotracers with high sensitivity, but images generally lack anatomic context and are of lower spatial resolution. Integration of these technologies permits the acquisition of temporally correlated data showing the distribution of PET radiotracers and MRI contrast agents or MR-detectable metabolites, with registration to the underlying anatomy. An MRI-compatible PET scanner has been built for biomedical research applications that allows data from both modalities to be acquired simultaneously. Experiments demonstrate no effect of the MRI system on the spatial resolution of the PET system and <10% reduction in the fraction of radioactive decay events detected by the PET scanner inside the MRI. The signal-to-noise ratio and uniformity of the MR images, with the exception of one particular pulse sequence, were little affected by the presence of the PET scanner. In vivo simultaneous PET and MRI studies were performed in mice. Proof-of-principle in vivo MR spectroscopy and functional MRI experiments were also demonstrated with the combined scanner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Molecular imaging of cancer with positron emission tomography
Gambhir, S. S. (2002) · Nature Reviews Cancer · doi:10.1038/nrc882 · Cited by 1,656
MRI-PET Registration with Automated Algorithm
Woods, R. P., Mazziotta, J. C., & R. Cherry, A. S. (1993) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-199307000-00004 · Cited by 1,617
Positron emission tomography provides molecular imaging of biological processes
Phelps, M. E. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.97.16.9226 · Cited by 1,229
Magnetic relaxation switches capable of sensing molecular interactions
Perez, J. M., Josephson, L., O'Loughlin, T., Högemann, D., & Weissleder, R. (2002) · Nature Biotechnology · doi:10.1038/nbt720 · Cited by 889
(2002) · Elsevier eBooks · doi:10.1016/b978-0-12-693019-1.x5000-x · Cited by 710
Functional imaging of the monkey brain
Logothetis, N. K., Guggenberger, H., Peled, S., & Pauls, J. (1999) · Nature Neuroscience · doi:10.1038/9210 · Cited by 540
Magnetic resonance spectroscopy of the human brain
Ross, B., & Bluml, S. (2001) · The Anatomical Record · doi:10.1002/ar.1058 · Cited by 411
Simultaneous PET and MR imaging
Shao, Y., Cherry, S. R., Farahani, K., Meadors, K., Siegel, S., Silverman, R. W., & Marsden, P. K. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/10/010 · Cited by 374
Self-citationCatana, C., Wu, Y., Judenhofer, M. S., Qi, J., Pichler, B. J., & Cherry, S. R. (2006) · PubMed · Cited by 350
Self-citation
Cited by
The role of porphyrin chemistry in tumor imaging and photodynamic therapy
Ethirajan, M., Chen, Y., Joshi, P., & Pandey, R. K. (2011) · Chem. Soc. Rev. · doi:10.1039/b915149b · Cited by 2,034
Chemical Design and Synthesis of Functionalized Probes for Imaging and Treating Tumor Hypoxia
Liu, J.-N., Bu, W., & Shi, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00525 · Cited by 838
Modern Diagnostic Imaging Technique Applications and Risk Factors in the Medical Field: A Review
Hussain, S., Mubeen, I., Ullah, N., Shah, S. S. U. D., Khan, B. A., Zahoor, M., Ullah, R., Khan, F. A., & Sultan, M. A. (2022) · BioMed Research International · doi:10.1155/2022/5164970 · Cited by 787
Martinez-Möller, A., Souvatzoglou, M., Delso, G., Bundschuh, R. A., Chefd'hotel, C., Ziegler, S. I., Navab, N., Schwaiger, M., & Nekolla, S. G. (2009) · Journal of Nuclear Medicine · doi:10.2967/jnumed.108.054726 · Cited by 712
Evidence for brain glial activation in chronic pain patients
Loggia, M. L., Chonde, D. B., Akeju, O., Arabasz, G., Catana, C., Edwards, R. R., Hill, E., Hsu, S., Izquierdo-Garcia, D., Ji, R.-R., et al. (2015) · Brain · doi:10.1093/brain/awu377 · Cited by 503
Self-citationA smart and versatile theranostic nanomedicine platform based on nanoporphyrin
Li, Y., Lin, T.-Y., Luo, Y., Liu, Q., Xiao, W., Guo, W., Lac, D., Zhang, H., Feng, C., Wachsmann-Hogiu, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms5712 · Cited by 414
Self-citationDesign and performance evaluation of a whole-body Ingenuity TF PET–MRI system
Zaidi, H., Ojha, N., Morich, M., Griesmer, J., Hu, Z., Maniawski, P., Ratib, O., Izquierdo-Garcia, D., Fayad, Z. A., & Shao, L. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/10/013 · Cited by 402
Catana, C., van der Kouwe, A., Benner, T., Michel, C. J., Hamm, M., Fenchel, M., Fischl, B., Rosen, B., Schmand, M., & Sorensen, A. G. (2010) · Journal of Nuclear Medicine · doi:10.2967/jnumed.109.069112 · Cited by 359
Self-citationTowards quantitative PET/MRI: a review of MR-based attenuation correction techniques
Hofmann, M., Pichler, B., Schölkopf, B., & Beyer, T. (2009) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s00259-008-1007-7 · Cited by 343
Self-citationPET/MRI of Inflammation in Myocardial Infarction
Lee, W. W., Marinelli, B., van der Laan, A. M., Sena, B. F., Gorbatov, R., Leuschner, F., Dutta, P., Iwamoto, Y., Ueno, T., Begieneman, M. P. V., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.08.066 · Cited by 340
Multimodality Imaging: Beyond PET/CT and SPECT/CT
Cherry, S. R. (2009) · Seminars in Nuclear Medicine · doi:10.1053/j.semnuclmed.2009.03.001 · Cited by 238
“Two MR-compatible PET scanners based on avalanche photodiode detector technology have been developed for small animal imaging and have been successfully applied for a range of in vivo applications [22,23].”
BackgroundSelf-citationMultimodality Cardiovascular Molecular Imaging, Part I
Sinusas, A. J., Bengel, F., Nahrendorf, M., Epstein, F. H., Wu, J. C., Villanueva, F. S., Fayad, Z. A., & Gropler, R. J. (2008) · Circulation: Cardiovascular Imaging · doi:10.1161/circimaging.108.824359 · Cited by 175
Bimodal MR–PET Agent for Quantitative pH Imaging
Frullano, L., Catana, C., Benner, T., Sherry, A. D., & Caravan, P. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.201000075 · Cited by 172
Self-citationLeuschner, F., & Nahrendorf, M. (2011) · Circulation Research · doi:10.1161/circresaha.110.232678 · Cited by 110
Metadata
- Authors
- Catana, C., Procissi, D., Wu, Y., Judenhofer, M. S., Qi, J., Pichler, B. J., Jacobs, R. E., & Cherry, S. R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2008-03-11
- Volume
- 105
- Issue
- 10
- Pages
- 3705-3710
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2092726542
- Cited by
- 272
- References
- 32
- FWCI
- 25.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.