The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Multiplex protein assays based on real-time magnetic nanotag sensing
Open accessAbstract
Magnetic nanotags (MNTs) are a promising alternative to fluorescent labels in biomolecular detection assays, because minute quantities of MNTs can be detected with inexpensive giant magnetoresistive (GMR) sensors, such as spin valve (SV) sensors. However, translating this promise into easy to use and multilplexed protein assays, which are highly sought after in molecular diagnostics such as cancer diagnosis and treatment monitoring, has been challenging. Here, we demonstrate multiplex protein detection of potential cancer markers at subpicomolar concentration levels and with a dynamic range of more than four decades. With the addition of nanotag amplification, the analytic sensitivity extends into the low fM concentration range. The multianalyte ability, sensitivity, scalability, and ease of use of the MNT-based protein assay technology make it a strong contender for versatile and portable molecular diagnostics in both research and clinical settings.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative Monitoring of Gene Expression Patterns with a Complementary DNA Microarray
Schena, M., Shalon, D., Davis, R. W., & Brown, P. O. (1995) · Science · doi:10.1126/science.270.5235.467 · Cited by 9,609
Self-citationMonodisperse MFe2O4 (M = Fe, Co, Mn) Nanoparticles
Sun, S., Zeng, H., Robinson, D. B., Raoux, S., Rice, P. M., Wang, S. X., & Li, G. (2004) · Journal of the American Chemical Society · doi:10.1021/ja0380852 · Cited by 3,441
Self-citationGiant room-temperature magnetoresistance in single-crystal Fe/MgO/Fe magnetic tunnel junctions
Yuasa, S., Nagahama, T., Fukushima, A., Suzuki, Y., & Ando, K. (2004) · Nature Materials · doi:10.1038/nmat1257 · Cited by 3,331
Sawyers, C. L. (2008) · Nature · doi:10.1038/nature06913 · Cited by 983
Colloidal Nanocrystal Shape and Size Control: The Case of Cobalt
Puntes, V. F., Krishnan, K. M., & Alivisatos, A. P. (2001) · Science · doi:10.1126/science.1058495 · Cited by 869
A biosensor based on magnetoresistance technology
Baselt, D. R., Lee, G. U., Natesan, M., Metzger, S. W., Sheehan, P. E., & Colton, R. J. (1998) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(98)00037-2 · Cited by 823
Multiplexed protein measurement: technologies and applications of protein and antibody arrays
Kingsmore, S. F. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd2006 · Cited by 715
The BARC biosensor applied to the detection of biological warfare agents
Edelstein, R. L., Tamanaha, C. R., Sheehan, P. E., Miller, M. M., Baselt, D. R., Whitman, L. J., & Colton, R. J. (2000) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(99)00054-8 · Cited by 456
Li, G., Joshi, V., White, R. L., Wang, S. X., Kemp, J. T., Webb, C., Davis, R. W., & Sun, S. (2003) · Journal of Applied Physics · doi:10.1063/1.1540176 · Cited by 221
Self-citationUhlen, M. (1989) · Nature · doi:10.1038/340733a0 · Cited by 219
Li, G., Sun, S., Wilson, R. J., White, R. L., Pourmand, N., & Wang, S. X. (2006) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2005.10.001 · Cited by 216
Self-citationGiant magnetoresistive biochip for DNA detection and HPV genotyping
Xu, L., Yu, H., Akhras, M. S., Han, S.-J., Osterfeld, S., White, R. L., Pourmand, N., & Wang, S. X. (2008) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2008.03.030 · Cited by 163
Self-citationA Fluorophore‐Based Bio‐Barcode Amplification Assay for Proteins
Oh, B., Nam, J., Lee, S. W., & Mirkin, C. A. (2005) · Small · doi:10.1002/smll.200500260 · Cited by 137
Birken, S., Berger, P., Bidart, J., Weber, M. M., Bristow, A., Norman, R. J., Sturgeon, C. M., & Stenman, U. (2003) · Clinical Chemistry · doi:10.1373/49.1.144 · Cited by 113
Passivation and corrosion of microelectrode arrays
Schmitt, G., Schultze, J. W., Faßbender, F. J., Buß, G., Luth, H., & Schöning, M. J. (1999) · Electrochimica Acta · doi:10.1016/s0013-4686(99)00094-8 · Cited by 95
Disappearance of human chorionic gonadotropin and its α- and β-subunits after term pregnancy
Korhonen, J., Alfthan, H. V., Ylöstalo, P., Veldhuis, J. D., & Stenman, U. (1997) · Clinical Chemistry · doi:10.1093/clinchem/43.11.2155 · Cited by 59
Standardization of FSH, LH and hCG—Current position and future prospects
Sturgeon, C. M., & Ellis, A. R. (2006) · Molecular and Cellular Endocrinology · doi:10.1016/j.mce.2006.09.004 · Cited by 32
Cited by
Biomedical Nanomagnetics: A Spin Through Possibilities in Imaging, Diagnostics, and Therapy
Krishnan, K. M. (2010) · IEEE Transactions on Magnetics · doi:10.1109/tmag.2010.2046907 · Cited by 819
Signal amplification using functional nanomaterials for biosensing
Lei, J., & Ju, H. (2012) · Chemical Society Reviews · doi:10.1039/c1cs15274b · Cited by 588
Nanoparticles: Alternatives Against Drug-Resistant Pathogenic Microbes
Rudramurthy, G., Swamy, M., Sinniah, U., & Ghasemzadeh, A. (2016) · Molecules · doi:10.3390/molecules21070836 · Cited by 556
Magnetic nanoparticle biosensors
Haun, J. B., Yoon, T., Lee, H., & Weissleder, R. (2010) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.84 · Cited by 550
Nanoparticles and their applications in cell and molecular biology
Wang, E. C., & Wang, A. Z. (2014) · Integrative Biology · doi:10.1039/c3ib40165k · Cited by 415
Metadata
- Authors
- Osterfeld, S. J., Yu, H., Gaster, R. S., Caramuta, S., Xu, L., Han, S.-J., Hall, D. A., Wilson, R. J., Sun, S., White, R. L., Davis, R. W., Pourmand, N., & Wang, S. X.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2008-12-30
- Volume
- 105
- Issue
- 52
- Pages
- 20637-20640
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2096143567
- Cited by
- 288
- References
- 17
- FWCI
- 7.69
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.