The DOI matches its Crossref record; 35 of the 35 references it cites were found in a registry or an index.
Sensitivity of MRI resonance frequency to the orientation of brain tissue microstructure
Open accessAbstract
Recent advances in high-field (≥7 T) MRI have made it possible to study the fine structure of the human brain at the level of fiber bundles and cortical layers. In particular, techniques aimed at detecting MRI resonance frequency shifts originating from local variation in magnetic susceptibility and other sources have greatly improved the visualization of these structures. A recent theoretical study [He X, Yablonskiy DA (2009) Proc Natl Acad Sci USA 106:13558–13563] suggests that MRI resonance frequency may report not only on tissue composition, but also on microscopic compartmentalization of susceptibility inclusions and their orientation relative to the magnetic field. The proposed sensitivity to tissue structure may greatly expand the information available with conventional MRI techniques. To investigate this possibility, we studied postmortem tissue samples from human corpus callosum with an experimental design that allowed separation of microstructural effects from confounding macrostructural effects. The results show that MRI resonance frequency does depend on microstructural orientation. Furthermore, the spatial distribution of the resonance frequency shift suggests an origin related to anisotropic susceptibility effects rather than microscopic compartmentalization. This anisotropy, which has been shown to depend on molecular ordering, may provide valuable information about tissue molecular structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Solid State Physics
Kittel, C., & Fan, H. Y. (1957) · American Journal of Physics · doi:10.1119/1.1934457 · Cited by 22,240
Advances in functional and structural MR image analysis and implementation as FSL
Smith, S. M., Jenkinson, M., Woolrich, M. W., Beckmann, C. F., Behrens, T. E. J., Johansen-Berg, H., Bannister, P. R., De Luca, M., Drobnjak, I., Flitney, D. E., et al. (2004) · NeuroImage · doi:10.1016/j.neuroimage.2004.07.051 · Cited by 13,630 · cited 1×
“Phase images were calculated from the complex sum of the individual coil data after correcting for each coil’s phase offset (37).”
MethodIntroduction to Solid State Physics
Kittel, C., & Dexter, D. L. (1953) · American Journal of Physics · doi:10.1119/1.1933590 · Cited by 13,240
Basser, P. J., & Pierpaoli, C. (1996) · Journal of Magnetic Resonance, Series B · doi:10.1006/jmrb.1996.0086 · Cited by 4,306
Magnetization transfer contrast (MTC) and tissue water proton relaxation in vivo
Wolff, S. D., & Balaban, R. S. (1989) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910100113 · Cited by 1,482
Imaging iron stores in the brain using magnetic resonance imaging
Haacke, E. M., Cheng, N. Y. C., House, M. J., Liu, Q., Neelavalli, J., Ogg, R. J., Khan, A., Ayaz, M., Kirsch, W., & Obenaus, A. (2005) · Magnetic Resonance Imaging · doi:10.1016/j.mri.2004.10.001 · Cited by 995
Lipid composition of the normal human brain: gray matter, white matter, and myelin
O'Brien, J. S., & Sampson, E. L. (1965) · Journal of Lipid Research · doi:10.1016/s0022-2275(20)39619-x · Cited by 848
Tolman, J. R., Flanagan, J. M., Kennedy, M. A., & Prestegard, J. H. (1995) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.92.20.9279 · Cited by 837
Fast, automated, N‐dimensional phase‐unwrapping algorithm
Jenkinson, M. (2003) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10354 · Cited by 695
High-field MRI of brain cortical substructure based on signal phase
Duyn, J. H., van Gelderen, P., Li, T.-Q., de Zwart, J. A., Koretsky, A. P., & Fukunaga, M. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0610821104 · Cited by 641
Self-citationMagnetic susceptibility mapping of brain tissue in vivo using MRI phase data
Shmueli, K., de Zwart, J. A., van Gelderen, P., Li, T., Dodd, S. J., & Duyn, J. H. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22135 · Cited by 527
Self-citationThe theory of electrons and its applications to the phenomena of light and radiant heat
Lorentz, H. A. (2007) · CERN Document Server (European Organization for Nuclear Research) · Cited by 472
Marques, J. P., & Bowtell, R. (2005) · Concepts in Magnetic Resonance Part B: Magnetic Resonance Engineering · doi:10.1002/cmr.b.20034 · Cited by 434
Layer-specific variation of iron content in cerebral cortex as a source of MRI contrast
Fukunaga, M., Li, T.-Q., van Gelderen, P., de Zwart, J. A., Shmueli, K., Yao, B., Lee, J., Maric, D., Aronova, M. A., Zhang, G., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0911177107 · Cited by 408
Self-citationChu, K. ‐. C., Xu, Y., Balschi, J. A., & Springer, C. S. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910130207 · Cited by 373
Aldehyde fixative solutions alter the water relaxation and diffusion properties of nervous tissue
Shepherd, T. M., Thelwall, P. E., Stanisz, G. J., & Blackband, S. J. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21977 · Cited by 305
Skare, S., Hedehus, M., Moseley, M. E., & Li, T.-Q. (2000) · Journal of Magnetic Resonance · doi:10.1006/jmre.2000.2209 · Cited by 297
Susceptibility contrast in high field MRI of human brain as a function of tissue iron content
Yao, B., Li, T.-Q., Gelderen, P. V., Shmueli, K., de Zwart, J. A., & Duyn, J. H. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2008.10.029 · Cited by 282
Self-citationBiophysical mechanisms of phase contrast in gradient echo MRI
He, X., & Yablonskiy, D. A. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0904899106 · Cited by 272
Ogg, R. J., Langston, J. W., Haacke, E. M., Steen, R. G., & Taylor, J. S. (1999) · Magnetic Resonance Imaging · doi:10.1016/s0730-725x(99)00017-x · Cited by 205
Formalin fixation alters water diffusion coefficient magnitude but not anisotropy in infarcted brain
Sun, S., Neil, J. J., Liang, H., He, Y. Y., Schmidt, R. E., Hsu, C. Y., & Song, S. (2005) · Magnetic Resonance in Medicine · doi:10.1002/mrm.20488 · Cited by 204 · cited 1×
“Moreover, frequency contrasts quantitatively similar to those observed in vivo have been observed in fixed tissues (31).”
BackgroundStructural origins of diamagnetic anisotropy in proteins.
Worcester, D. L. (1978) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.75.11.5475 · Cited by 191
Deistung, A., Rauscher, A., Sedlacik, J., Stadler, J., Witoszynskyj, S., & Reichenbach, J. R. (2008) · Magnetic Resonance in Medicine · doi:10.1002/mrm.21754 · Cited by 169
de Zwart, J. A., van Gelderen, P., Kellman, P., & Duyn, J. H. (2002) · Magnetic Resonance in Medicine · doi:10.1002/mrm.10303 · Cited by 145
Self-citationHigh‐resolution 7T MRI of the human hippocampus in vivo
Thomas, B. P., Welch, E. B., Niederhauser, B. D., Whetsell, W. O., Anderson, A. W., Gore, J. C., Avison, M. J., & Creasy, J. L. (2008) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.21576 · Cited by 129
The molecular basis for gray and white matter contrast in phase imaging
Zhong, K., Leupold, J., von Elverfeldt, D., & Speck, O. (2008) · NeuroImage · doi:10.1016/j.neuroimage.2008.01.061 · Cited by 128
Marques, J. P., Maddage, R., Mlynárik, V., & Gruetter, R. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.02.023 · Cited by 123
Characterization of T2* heterogeneity in human brain white matter
Li, T., Yao, B., van Gelderen, P., Merkle, H., Dodd, S. J., Talagala, L., Koretsky, A. P., & Duyn, J. H. (2009) · Magnetic Resonance in Medicine · doi:10.1002/mrm.22156 · Cited by 94
Self-citationMagnetic anisotropy of egg lecithin membranes
Boroske, E., & Helfrich, W. (1978) · Biophysical Journal · doi:10.1016/s0006-3495(78)85425-3 · Cited by 92
Magnetic Anisotropy and the Orientation of Retinal Rods in a Homogeneous Magnetic Field
Hong, F. T., Mauzerall, D., & Mauro, A. (1971) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.68.6.1283 · Cited by 84
On the contribution of deoxy-hemoglobin to MRI gray–white matter phase contrast at high field
Lee, J., Hirano, Y., Fukunaga, M., Silva, A. C., & Duyn, J. H. (2009) · NeuroImage · doi:10.1016/j.neuroimage.2009.07.017 · Cited by 75
Self-citationON THE MAGNETIC ASYMMETRY OF MUSCLE FIBERS
Arnold, W., Steele, R., & Mueller, H. (1958) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.44.1.1 · Cited by 37
Dynorphin induced magnetic ordering in lipid bilayers as studied by 31P NMR spectroscopy
Naito, A., Nagao, T., Obata, M., Shindo, Y., Okamoto, M., Yokoyama, S., Tuzi, S., & Saitô, H. (2002) · Biochimica et Biophysica Acta (BBA) - Biomembranes · doi:10.1016/s0005-2736(01)00420-5 · Cited by 36
Using magnetic orientation to study structure and assembly
Torbet, J. (1987) · Trends in Biochemical Sciences · doi:10.1016/0968-0004(87)90152-6 · Cited by 34
Basser (2000) · doi:10.1002/1522-2594(200010)44:4<625::aid-mrm17>3.0.co;2-o
Research works printed but not linked: 6
- 10.1098/rspa.1975.0073 · doi:10.1098/rspa.1975.0073
- S Aravamudhan, Magnetized materials: Contributions inside Lorentz ellipsoids. Indian J Phys 79, 985–989 (2005).
- 10.1103/PhysRevLett.35.397 · doi:10.1103/physrevlett.35.397
- 10.1038/289091a0 · doi:10.1038/289091a0
- 10.1016/S0006-3495(84)84196-X · doi:10.1016/s0006-3495(84)84196-x
- 10.1016/S0006-3495(87)83394-5 · doi:10.1016/s0006-3495(87)83394-5
Cited by
Quantitative susceptibility mapping (QSM): Decoding MRI data for a tissue magnetic biomarker
Wang, Y., & Liu, T. (2015) · Magnetic Resonance in Medicine · doi:10.1002/mrm.25358 · Cited by 878
Langkammer, C., Schweser, F., Krebs, N., Deistung, A., Goessler, W., Scheurer, E., Sommer, K., Reishofer, G., Yen, K., Fazekas, F., et al. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.049 · Cited by 801
Schweser, F., Deistung, A., Lehr, B. W., & Reichenbach, J. R. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.10.070 · Cited by 710
Quantitative susceptibility mapping of human brain reflects spatial variation in tissue composition
Li, W., Wu, B., & Liu, C. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2010.11.088 · Cited by 624
Pros and cons of ultra-high-field MRI/MRS for human application
Ladd, M. E., Bachert, P., Meyerspeer, M., Moser, E., Nagel, A. M., Norris, D. G., Schmitter, S., Speck, O., Straub, S., & Zaiss, M. (2018) · Progress in Nuclear Magnetic Resonance Spectroscopy · doi:10.1016/j.pnmrs.2018.06.001 · Cited by 544
Metadata
- Authors
- Lee, J., Shmueli, K., Fukunaga, M., van Gelderen, P., Merkle, H., Silva, A. C., & Duyn, J. H.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2010-03-02
- Volume
- 107
- Issue
- 11
- Pages
- 5130-5135
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2029347131
- Cited by
- 263
- References
- 35
- FWCI
- 18.56
- Type
- journal article
- Language
- en
- Update notices
- correction (2010-04-07)
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.