The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Injectable hydrogel microbeads for fluorescence-based in vivo continuous glucose monitoring
Open accessAbstract
Fluorescent microbeads hold great promise for in vivo continuous glucose monitoring with wireless transdermal transmission and long-lasting activity. The full potential of fluorescent microbeads has yet to be realized due to insufficient intensity for transdermal transmission and material toxicity. This paper illustrates the highly-sensitive, biostable, long-lasting, and injectable fluorescent microbeads for in vivo continuous glucose monitoring. We synthesized a fluorescent monomer composed of glucose-recognition sites, a fluorogenic site, spacers, and polymerization sites. The spacers are designed to be long and hydrophilic for increasing opportunities to bind glucose molecules; consequently, the fluorescent monomers enable high-intensive responsiveness to glucose. We then fabricated injectable-sized fluorescent polyacrylamide hydrogel beads with high uniformity and high throughput. We found that our fluorescent beads provide sufficient intensity to transdermally monitor glucose concentrations in vivo. The fluorescence intensity successfully traced the blood glucose concentration fluctuation, indicating our method has potential uses in highly-sensitive and minimally invasive continuous blood glucose monitoring.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Biochemistry and molecular cell biology of diabetic complications
Brownlee, M. (2001) · Nature · doi:10.1038/414813a · Cited by 9,107
Global and societal implications of the diabetes epidemic
Zimmet, P., Alberti, K. G. M. M., & Shaw, J. (2001) · Nature · doi:10.1038/414782a · Cited by 5,883
Lee, T. H., Marcantonio, E. R., Mangione, C. M., Thomas, E. J., Polanczyk, C. A., Cook, E. F., Sugarbaker, D. J., Donaldson, M. C., Poss, R., Ho, K. K. L., et al. (1999) · Circulation · doi:10.1161/01.cir.100.10.1043 · Cited by 3,771
Discher, D. E., & Eisenberg, A. (2002) · Science · doi:10.1126/science.1074972 · Cited by 3,551
Nestler, E. J., Barrot, M., DiLeone, R. J., Eisch, A. J., Gold, S. J., & Monteggia, L. M. (2002) · Neuron · doi:10.1016/s0896-6273(02)00653-0 · Cited by 3,217
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
Protein kinase C activation and the development of diabetic complications.
Koya, D., & King, G. L. (1998) · Diabetes · doi:10.2337/diabetes.47.6.859 · Cited by 1,330
A reversibly antigen-responsive hydrogel
Miyata, T., Asami, N., & Uragami, T. (1999) · Nature · doi:10.1038/21619 · Cited by 1,166
Klonoff, D. C. (2005) · Diabetes Care · doi:10.2337/diacare.28.5.1231 · Cited by 724
Controlled growth factor release from synthetic extracellular matrices
Lee, K. Y., Peters, M. C., Anderson, K. W., & Mooney, D. J. (2000) · Nature · doi:10.1038/35050141 · Cited by 505
James, T. D., Sandanayake, K. R. A. S., Iguchi, R., & Shinkai, S. (1995) · Journal of the American Chemical Society · doi:10.1021/ja00140a013 · Cited by 485
Functional and Molecular Defects of Pancreatic Islets in Human Type 2 Diabetes
Del Guerra, S., Lupi, R., Marselli, L., Masini, M., Bugliani, M., Sbrana, S., Torri, S., Pollera, M., Boggi, U., Mosca, F., et al. (2005) · Diabetes · doi:10.2337/diabetes.54.3.727 · Cited by 466 · cited 1×
“D is a global pandemic affecting over 200 million people (1, 2).”
BackgroundEnzyme-Based Biosensors for in Vivo Measurements
Wilson, G. S., & Hu, Y. (2000) · Chemical Reviews · doi:10.1021/cr990003y · Cited by 434
Russell, R. J., Pishko, M. V., Gefrides, C. C., McShane, M. J., & Coté, G. L. (1999) · Analytical Chemistry · doi:10.1021/ac990060r · Cited by 353
Mosqueira, V. C. F., Legrand, P., Morgat, J.-L., Vert, M., Mysiakine, E., Gref, R., Devissaguet, J.-P., & Barratt, G. (2001) · Pharmaceutical Research · doi:10.1023/a:1012248721523 · Cited by 289
Martín‐Banderas, L., Flores‐Mosquera, M., Riesco‐Chueca, P., Rodríguez‐Gil, A., Cebolla, Á., Chávez, S., & Gañán‐Calvo, A. M. (2005) · Small · doi:10.1002/smll.200500087 · Cited by 206
Aussedat, B., Dupire-Angel, M., Gifford, R., Klein, J. C., Wilson, G. S., & Reach, G. (2000) · American Journal of Physiology-Endocrinology and Metabolism · doi:10.1152/ajpendo.2000.278.4.e716 · Cited by 186
Concanavalin A for in vivo glucose sensing: A biotoxicity review
Ballerstädt, R., Evans, C., McNichols, R. J., & Gowda, A. (2006) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.01.008 · Cited by 146
Glucose measurement in patients with diabetes mellitus with dermal interstitial fluid
Bantle, J. P., & Thomas, W. (1997) · Journal of Laboratory and Clinical Medicine · doi:10.1016/s0022-2143(97)90044-5 · Cited by 128
Kenausis, G., Chen, Q., & Heller, A. (1997) · Analytical Chemistry · doi:10.1021/ac961083y · Cited by 118
Saccharide-Selective Boronic Acid Based Photoinduced Electron Transfer (PET) Fluorescent Sensors
James, T. D. (2007) · Springer eBooks · doi:10.1007/128_2007_110 · Cited by 111
Biosensors for in vivo glucose measurement: can we cross the experimental stage
Abel, P., & von Woedtke, T. (2002) · Biosensors and Bioelectronics · doi:10.1016/s0956-5663(02)00099-4 · Cited by 90
Kondepati, V. R., & Heise, H. M. (2007) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-007-1229-8 · Cited by 85
Huang, S., Tan, W.-H., Tseng, F., et al. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/11/013 · Cited by 85
Sugar‐Responsive Fluorescent Nanospheres
Zenkl, G., Mayr, T., & Klimant, I. (2007) · Macromolecular Bioscience · doi:10.1002/mabi.200700174 · Cited by 67
Operation of a Miniature Redox Hydrogel-Based Pyruvate Sensor in Undiluted Deoxygenated Calf Serum
Gajovic, N., Binyamin, G. N., Warsinke, A., Scheller, F. W., & Heller, A. (2000) · Analytical Chemistry · doi:10.1021/ac991021i · Cited by 66
A biocompatible enzyme electrode for continuous in vivo glucose monitoring in whole blood
Turner, R. F. B., Harrison, D. J., Rajotte, R. V., & Baltes, H. (1990) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(90)80273-3 · Cited by 51
Fluorescent acrylamide nanoparticles for boronic acid based sugar sensing — from probes to sensors
Zenkl, G., & Klimant, I. (2009) · Microchimica Acta · doi:10.1007/s00604-009-0172-0 · Cited by 36
Microporated PEG Spheres for Fluorescent Analyte Detection
Rounds, R. M., Ibey, B. L., Beier, H. T., Pishko, M. V., & Coté, G. L. (2006) · Journal of Fluorescence · doi:10.1007/s10895-006-0143-3 · Cited by 35
Cited by
Lu, Y., Aimetti, A. A., Langer, R., & Gu, Z. (2016) · Nature Reviews Materials · doi:10.1038/natrevmats.2016.75 · Cited by 1,421
Translational Applications of Hydrogels
Correa, S., Grosskopf, A. K., Lopez Hernandez, H., Chan, D., Yu, A. C., Stapleton, L. M., & Appel, E. A. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c01177 · Cited by 1,143
Liu, X., Liu, J., Lin, S., & Zhao, X. (2020) · Materials Today · doi:10.1016/j.mattod.2019.12.026 · Cited by 1,023
Synthesis and Applications of Boronic Acid-Containing Polymers: From Materials to Medicine
Brooks, W. L. A., & Sumerlin, B. S. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00300 · Cited by 981
Chitosan based hydrogels and their applications for drug delivery in wound dressings: A review
Hamedi, H., Moradi, S., Hudson, S. M., & Tonelli, A. E. (2018) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2018.06.114 · Cited by 759
Metadata
- Authors
- Shibata, H., Heo, Y. J., Okitsu, T., Matsunaga, Y., Kawanishi, T., & Takeuchi, S.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2010-10-04
- Volume
- 107
- Issue
- 42
- Pages
- 17894-17898
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2027544789
- Cited by
- 287
- References
- 29
- FWCI
- 5.50
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.