The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Electrical detection of pathogenic bacteria via immobilized antimicrobial peptides
Open accessAbstract
The development of a robust and portable biosensor for the detection of pathogenic bacteria could impact areas ranging from water-quality monitoring to testing of pharmaceutical products for bacterial contamination. Of particular interest are detectors that combine the natural specificity of biological recognition with sensitive, label-free sensors providing electronic readout. Evolution has tailored antimicrobial peptides to exhibit broad-spectrum activity against pathogenic bacteria, while retaining a high degree of robustness. Here, we report selective and sensitive detection of infectious agents via electronic detection based on antimicrobial peptide-functionalized microcapacitive electrode arrays. The semiselective antimicrobial peptide magainin I—which occurs naturally on the skin of African clawed frogs—was immobilized on gold microelectrodes via a C-terminal cysteine residue. Significantly, exposing the sensor to various concentrations of pathogenic Escherichia coli revealed detection limits of approximately 1 bacterium/μL, a clinically useful detection range. The peptide-microcapacitive hybrid device was further able to demonstrate both Gram-selective detection as well as interbacterial strain differentiation, while maintaining recognition capabilities toward pathogenic strains of E. coli and Salmonella . Finally, we report a simulated “water-sampling” chip, consisting of a microfluidic flow cell integrated onto the hybrid sensor, which demonstrates real-time on-chip monitoring of the interaction of E. coli cells with the antimicrobial peptides. The combination of robust, evolutionarily tailored peptides with electronic read-out monitoring electrodes may open exciting avenues in both fundamental studies of the interactions of bacteria with antimicrobial peptides, as well as the practical use of these devices as portable pathogen detectors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antimicrobial peptides of multicellular organisms
Zasloff, M. (2002) · Nature · doi:10.1038/415389a · Cited by 8,457
Weighing of biomolecules, single cells and single nanoparticles in fluid
Burg, T. P., Godin, M., Knudsen, S. M., Shen, W., Carlson, G., Foster, J. S., Babcock, K., & Manalis, S. R. (2007) · Nature · doi:10.1038/nature05741 · Cited by 1,213
Cited by
Graphene-based wireless bacteria detection on tooth enamel
Mannoor, M. S., Tao, H., Clayton, J. D., Sengupta, A., Kaplan, D. L., Naik, R. R., Verma, N., Omenetto, F. G., & McAlpine, M. C. (2012) · Nature Communications · doi:10.1038/ncomms1767 · Cited by 1,014
Self-citationElectrochemical biosensors for pathogen detection
Cesewski, E., & Johnson, B. N. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112214 · Cited by 902
Foudeh, A. M., Fatanat Didar, T., Veres, T., & Tabrizian, M. (2012) · Lab on a Chip · doi:10.1039/c2lc40630f · Cited by 457
Skin-Friendly Electronics for Acquiring Human Physiological Signatures
Zhang, Y., & Tao, T. H. (2019) · Advanced Materials · doi:10.1002/adma.201905767 · Cited by 140
Discovery and development of a synthetic peptide derived from lactoferrin for clinical use
Brouwer, C. P. J. M., Rahman, M., & Welling, M. M. (2011) · Peptides · doi:10.1016/j.peptides.2011.07.017 · Cited by 90
Metadata
- Authors
- Mannoor, M. S., Zhang, S., Link, A. J., & McAlpine, M. C.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2010-10-18
- Volume
- 107
- Issue
- 45
- Pages
- 19207-19212
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2072216523
- Cited by
- 357
- References
- 2
- FWCI
- 13.71
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Electrical detection of pathogenic bacteria via immobilized antimicrobial peptides. https://app.cochat.ai/papers/10.1073/pnas.1008768107
- The paper
- Mannoor, M. S., Zhang, S., Link, A. J., & McAlpine, M. C. (2010). Electrical detection of pathogenic bacteria via immobilized antimicrobial peptides. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1008768107
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.