The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Lens-free optical tomographic microscope with a large imaging volume on a chip
Open accessAbstract
We present a lens-free optical tomographic microscope, which enables imaging a large volume of approximately 15 mm 3 on a chip, with a spatial resolution of < 1 μm × < 1 μm × < 3 μm in x , y and z dimensions, respectively. In this lens-free tomography modality, the sample is placed directly on a digital sensor array with, e.g., ≤ 4 mm distance to its active area. A partially coherent light source placed approximately 70 mm away from the sensor is employed to record lens-free in-line holograms of the sample from different viewing angles. At each illumination angle, multiple subpixel shifted holograms are also recorded, which are digitally processed using a pixel superresolution technique to create a single high-resolution hologram of each angular projection of the object. These superresolved holograms are digitally reconstructed for an angular range of ± 50°, which are then back-projected to compute tomograms of the sample. In order to minimize the artifacts due to limited angular range of tilted illumination, a dual-axis tomography scheme is adopted, where the light source is rotated along two orthogonal axes. Tomographic imaging performance is quantified using microbeads of different dimensions, as well as by imaging wild-type Caenorhabditis elegans . Probing a large volume with a decent 3D spatial resolution, this lens-free optical tomography platform on a chip could provide a powerful tool for high-throughput imaging applications in, e.g., cell and developmental biology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Cited by
Imaging without lenses: achievements and remaining challenges of wide-field on-chip microscopy
Greenbaum, A., Luo, W., Su, T.-W., Göröcs, Z., Xue, L., Isikman, S. O., Coskun, A. F., Mudanyali, O., & Ozcan, A. (2012) · Nature Methods · doi:10.1038/nmeth.2114 · Cited by 540
Self-citationLee, K., Kim, K., Jung, J., Heo, J., Cho, S., Lee, S., Chang, G., Jo, Y., Park, H., & Park, Y. (2013) · Sensors · doi:10.3390/s130404170 · Cited by 510
Optical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc40864c · Cited by 364
Self-citationHigh-throughput lensfree 3D tracking of human sperms reveals rare statistics of helical trajectories
Su, T.-W., Xue, L., & Ozcan, A. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1212506109 · Cited by 339
Self-citationWu, Y., Rivenson, Y., Zhang, Y., Wei, Z., Günaydin, H., Lin, X., & Ozcan, A. (2018) · Optica · doi:10.1364/optica.5.000704 · Cited by 327
Self-citation
Metadata
- Authors
- Isikman, S. O., Bishara, W., Mavandadi, S., Yu, F. W., Feng, S., Lau, R., & Ozcan, A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-04-19
- Volume
- 108
- Issue
- 18
- Pages
- 7296-7301
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2129799874
- Cited by
- 216
- References
- 2
- FWCI
- 13.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Lens-free optical tomographic microscope with a large imaging volume on a chip. https://app.cochat.ai/papers/10.1073/pnas.1015638108
- The paper
- Isikman, S. O., Bishara, W., Mavandadi, S., Yu, F. W., Feng, S., Lau, R., & Ozcan, A. (2011). Lens-free optical tomographic microscope with a large imaging volume on a chip. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1015638108
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.