Lens-free optical tomographic microscope with a large imaging volume on a chip
Open accessThe DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
We present a lens-free optical tomographic microscope, which enables imaging a large volume of approximately 15 mm 3 on a chip, with a spatial resolution of < 1 μm × < 1 μm × < 3 μm in x , y and z dimensions, respectively. In this lens-free tomography modality, the sample is placed directly on a digital sensor array with, e.g., ≤ 4 mm distance to its active area. A partially coherent light source placed approximately 70 mm away from the sensor is employed to record lens-free in-line holograms of the sample from different viewing angles. At each illumination angle, multiple subpixel shifted holograms are also recorded, which are digitally processed using a pixel superresolution technique to create a single high-resolution hologram of each angular projection of the object. These superresolved holograms are digitally reconstructed for an angular range of ± 50°, which are then back-projected to compute tomograms of the sample. In order to minimize the artifacts due to limited angular range of tilted illumination, a dual-axis tomography scheme is adopted, where the light source is rotated along two orthogonal axes. Tomographic imaging performance is quantified using microbeads of different dimensions, as well as by imaging wild-type Caenorhabditis elegans . Probing a large volume with a decent 3D spatial resolution, this lens-free optical tomography platform on a chip could provide a powerful tool for high-throughput imaging applications in, e.g., cell and developmental biology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Stages of embryonic development of the zebrafish
Kimmel, C. B., Ballard, W. W., Kimmel, S. R., Ullmann, B., & Schilling, T. F. (1995) · Developmental Dynamics · doi:10.1002/aja.1002030302 · Cited by 12,037
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896 · cited 2×
“Whether an object satisfies this condition depends on the scattering properties of the specimen as much as the total thickness of its connected structure (57).”
Background
Cited by
Imaging without lenses: achievements and remaining challenges of wide-field on-chip microscopy
Greenbaum, A., Luo, W., Su, T.-W., Göröcs, Z., Xue, L., Isikman, S. O., Coskun, A. F., Mudanyali, O., & Ozcan, A. (2012) · Nature Methods · doi:10.1038/nmeth.2114 · Cited by 540
Self-citationLee, K., Kim, K., Jung, J., Heo, J., Cho, S., Lee, S., Chang, G., Jo, Y., Park, H., & Park, Y. (2013) · Sensors · doi:10.3390/s130404170 · Cited by 510
Optical imaging techniques for point-of-care diagnostics
Zhu, H., Isikman, S. O., Mudanyali, O., Greenbaum, A., & Ozcan, A. (2013) · Lab Chip · doi:10.1039/c2lc40864c · Cited by 364
Self-citationOzcan, A., & McLeod, E. (2016) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-092515-010849 · Cited by 352
Self-citationHigh-throughput lensfree 3D tracking of human sperms reveals rare statistics of helical trajectories
Su, T.-W., Xue, L., & Ozcan, A. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1212506109 · Cited by 339
Self-citationWu, Y., Rivenson, Y., Zhang, Y., Wei, Z., Günaydin, H., Lin, X., & Ozcan, A. (2018) · Optica · doi:10.1364/optica.5.000704 · Cited by 327
Self-citationWide-field computational imaging of pathology slides using lens-free on-chip microscopy
Greenbaum, A., Zhang, Y., Feizi, A., Chung, P.-L., Luo, W., Kandukuri, S. R., & Ozcan, A. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3009850 · Cited by 294
Self-citationQuantitative phase imaging based on holography: trends and new perspectives
Huang, Z., & Cao, L. (2024) · Light: Science & Applications · doi:10.1038/s41377-024-01453-x · Cited by 277
Wu, Y., & Ozcan, A. (2018) · Methods · doi:10.1016/j.ymeth.2017.08.013 · Cited by 260
Self-citationSynthetic aperture-based on-chip microscopy
Luo, W., Greenbaum, A., Zhang, Y., & Ozcan, A. (2015) · Light: Science & Applications · doi:10.1038/lsa.2015.34 · Cited by 257
Self-citationA Mechanical Biomarker of Cell State in Medicine
Di Carlo, D. (2012) · SLAS Technology · doi:10.1177/2211068211431630 · Cited by 233
“However, parallelization may be possible considering wide field-of-view imaging approaches that are becoming available.(71) Automated cell positioning is also potentially feasible using parallel microfluidic delivery.”
BackgroundGreenbaum, A., & Ozcan, A. (2012) · Optics Express · doi:10.1364/oe.20.003129 · Cited by 225
Self-citationWang, H., Ceylan Koydemir, H., Qiu, Y., Bai, B., Zhang, Y., Jin, Y., Tok, S., Yilmaz, E. C., Gumustekin, E., Rivenson, Y., et al. (2020) · Light: Science & Applications · doi:10.1038/s41377-020-00358-9 · Cited by 204
Self-citationHabaza, M., Gilboa, B., Roichman, Y., & Shaked, N. T. (2015) · Optics Letters · doi:10.1364/ol.40.001881 · Cited by 196
Optical diffraction tomography techniques for the study of cell pathophysiology
Kim, K., Yoon, J., Shin, S., Lee, S., Yang, S.-A., & Park, Y. (2016) · Journal of Biomedical Photonics & Engineering · doi:10.18287/jbpe16.02.020201 · Cited by 174
“Recently, lens-free holographic and phytography techniques have been introduced which simplifies optical setup for ODT [42, 43].”
Method
Metadata
- Authors
- Isikman, S. O., Bishara, W., Mavandadi, S., Yu, F. W., Feng, S., Lau, R., & Ozcan, A.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-04-19
- Volume
- 108
- Issue
- 18
- Pages
- 7296-7301
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2129799874
- Cited by
- 216
- References
- 3
- FWCI
- 13.73
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.