Synthetic aperture-based on-chip microscopy
Open accessAbstract
Wide field-of-view (FOV) and high-resolution imaging requires microscopy modalities to have large space-bandwidth products. Lensfree on-chip microscopy decouples resolution from FOV and can achieve a space-bandwidth product greater than one billion under unit magnification using state-of-the-art opto-electronic sensor chips and pixel super-resolution techniques. However, using vertical illumination, the effective numerical aperture (NA) that can be achieved with an on-chip microscope is limited by a poor signal-to-noise ratio (SNR) at high spatial frequencies and imaging artifacts that arise as a result of the relatively narrow acceptance angles of the sensor's pixels. Here, we report, for the first time, a synthetic aperture-based on-chip microscope in which the illumination angle is scanned across the surface of a dome to increase the effective NA of the reconstructed lensfree image to 1.4, achieving e.g., ∼250-nm resolution at 700-nm wavelength under unit magnification. This synthetic aperture approach not only represents the largest NA achieved to date using an on-chip microscope but also enables color imaging of connected tissue samples, such as pathology slides, by achieving robust phase recovery without the need for multi-height scanning or any prior information about the sample. To validate the effectiveness of this synthetic aperture-based, partially coherent, holographic on-chip microscope, we have successfully imaged color-stained cancer tissue slides as well as unstained Papanicolaou smears across a very large FOV of 20.5 mm2. This compact on-chip microscope based on a synthetic aperture approach could be useful for various applications in medicine, physical sciences and engineering that demand high-resolution wide-field imaging. An on-chip microscope that offers both a high-resolution and a wide field of view looks set to benefit the biological and physical sciences. The lensfree imaging device, developed by researchers at the University of California at Los Angeles, CA, USA, makes use a synthetic aperture approach to provide a very large effective numerical aperture of 1.4 over a field of view of >20 mm2; this is a much larger numerical aperture than previous lensfree approaches had realized (<0.9). Consequently, very high spatial resolution (for example, 250 nm at a wavelength of 700 nm) was achieved. By illuminating samples with light of three different wavelengths (470 nm, 532 nm and 632 nm), the researchers also obtained lens-free color images of samples such as breast cancer tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Introduction to Fourier optics
Goodman, J. W. (1968) · Cited by 10,608
Phase retrieval algorithms: a comparison
Fienup, J. R. (1982) · Applied Optics · doi:10.1364/ao.21.002758 · Cited by 5,596
Super-resolution image reconstruction: a technical overview
Park, S. C., Park, M. K., & Kang, M. G. (2003) · IEEE Signal Processing Magazine · doi:10.1109/msp.2003.1203207 · Cited by 3,282
Reconstruction of an object from the modulus of its Fourier transform
Fienup, J. R. (1978) · Optics Letters · doi:10.1364/ol.3.000027 · Cited by 1,836
Wide-field, high-resolution Fourier ptychographic microscopy
Zheng, G., Horstmeyer, R., & Yang, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.187 · Cited by 1,829
Colorization using optimization
Levin, A., Lischinski, D., & Weiss, Y. (2004) · ACM Transactions on Graphics · doi:10.1145/1015706.1015780 · Cited by 1,411
Phase contrast, a new method for the microscopic observation of transparent objects
Zernike, F. (1942) · Physica · doi:10.1016/s0031-8914(42)80035-x · Cited by 1,068
Multiplexed coded illumination for Fourier Ptychography with an LED array microscope
Tian, L., Li, X., Ramchandran, K., & Waller, L. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002376 · Cited by 584
Digital in-line holography for biological applications
Xu, W., Jericho, M. H., Meinertzhagen, I. A., & Kreuzer, H. J. (2001) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.191361398 · Cited by 576
Imaging without lenses: achievements and remaining challenges of wide-field on-chip microscopy
Greenbaum, A., Luo, W., Su, T.-W., Göröcs, Z., Xue, L., Isikman, S. O., Coskun, A. F., Mudanyali, O., & Ozcan, A. (2012) · Nature Methods · doi:10.1038/nmeth.2114 · Cited by 540
Self-citation
Cited by
Wu, Y., Rivenson, Y., Zhang, Y., Wei, Z., Günaydin, H., Lin, X., & Ozcan, A. (2018) · Optica · doi:10.1364/optica.5.000704 · Cited by 327
Self-citationComputational illumination for high-speed in vitro Fourier ptychographic microscopy
Tian, L., Liu, Z., Yeh, L.-H., Chen, M., Zhong, J., & Waller, L. (2015) · Optica · doi:10.1364/optica.2.000904 · Cited by 317
Wu, Y., & Ozcan, A. (2018) · Methods · doi:10.1016/j.ymeth.2017.08.013 · Cited by 260
Self-citationGӧrӧcs, Z., Tamamitsu, M., Bianco, V., Wolf, P., Roy, S., Shindo, K., Yanny, K., Wu, Y., Koydemir, H. C., Rivenson, Y., et al. (2018) · Light: Science & Applications · doi:10.1038/s41377-018-0067-0 · Cited by 188
Metadata
- Authors
- Luo, W., Greenbaum, A., Zhang, Y., & Ozcan, A.
- Venue
- Light: Science & Applications
- Published
- 2015-03-27
- Volume
- 4
- Issue
- 3
- Pages
- e261-e261
- ISSN
- 2047-7538 (ISSN-L)
- OpenAlex
- W2061360861
- Cited by
- 257
- References
- 38
- FWCI
- 13.93
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Synthetic aperture-based on-chip microscopy. https://app.cochat.ai/papers/10.1038/lsa.2015.34
- The paper
- Luo, W., Greenbaum, A., Zhang, Y., & Ozcan, A. (2015). Synthetic aperture-based on-chip microscopy. Light: Science & Applications. https://doi.org/10.1038/lsa.2015.34
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.