The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Intramembrane cavitation as a unifying mechanism for ultrasound-induced bioeffects
Open accessAbstract
The purpose of this study was to develop a unified model capable of explaining the mechanisms of interaction of ultrasound and biological tissue at both the diagnostic nonthermal, noncavitational (<100 mW·cm −2 ) and therapeutic, potentially cavitational (>100 mW·cm −2 ) spatial peak temporal average intensity levels. The cellular-level model (termed “bilayer sonophore”) combines the physics of bubble dynamics with cell biomechanics to determine the dynamic behavior of the two lipid bilayer membrane leaflets. The existence of such a unified model could potentially pave the way to a number of controlled ultrasound-assisted applications, including CNS modulation and blood–brain barrier permeabilization. The model predicts that the cellular membrane is intrinsically capable of absorbing mechanical energy from the ultrasound field and transforming it into expansions and contractions of the intramembrane space. It further predicts that the maximum area strain is proportional to the acoustic pressure amplitude and inversely proportional to the square root of the frequency ( ) and is intensified by proximity to free surfaces, the presence of nearby microbubbles in free medium, and the flexibility of the surrounding tissue. Model predictions were experimentally supported using transmission electron microscopy (TEM) of multilayered live-cell goldfish epidermis exposed in vivo to continuous wave (CW) ultrasound at cavitational (1 MHz) and noncavitational (3 MHz) conditions. Our results support the hypothesis that ultrasonically induced bilayer membrane motion, which does not require preexistence of air voids in the tissue, may account for a variety of bioeffects and could elucidate mechanisms of ultrasound interaction with biological tissue that are currently not fully understood.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Intermolecular and Surface Forces
(2011) · Intermolecular and Surface Forces · doi:10.1016/b978-0-12-391927-4.10024-6 · Cited by 16,923
Intermolecular and Surface Forces
(2011) · Elsevier eBooks · doi:10.1016/c2011-0-05119-0 · Cited by 8,968
Leighton, T. G. (2012) · Cited by 2,284
Scaling the Microrheology of Living Cells
Fabry, B., Maksym, G. N., Butler, J. P., Glogauer, M., Navajas, D., & Fredberg, J. J. (2001) · Physical Review Letters · doi:10.1103/physrevlett.87.148102 · Cited by 1,261
Boal, D. (2001) · Cambridge University Press eBooks · doi:10.1017/cbo9780511810954 · Cited by 842
Ultrasound–biophysics mechanisms
O’Brien, W. D. (2007) · Progress in Biophysics and Molecular Biology · doi:10.1016/j.pbiomolbio.2006.07.010 · Cited by 745
Remote Excitation of Neuronal Circuits Using Low-Intensity, Low-Frequency Ultrasound
Tyler, W. J., Tufail, Y., Finsterwald, M., Tauchmann, M. L., Olson, E. J., & Majestic, C. (2008) · PLoS ONE · doi:10.1371/journal.pone.0003511 · Cited by 707
Mechanical Bioeffects of Ultrasound
Dalecki, D. (2004) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.6.040803.140126 · Cited by 564
Ultrasound, cavitation bubbles and their interaction with cells
Wu, J., & Nyborg, W. L. (2008) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2008.03.009 · Cited by 544
Water Permeability and Mechanical Strength of Polyunsaturated Lipid Bilayers
Olbrich, K., Rawicz, W., Needham, D., & Evans, E. (2000) · Biophysical Journal · doi:10.1016/s0006-3495(00)76294-1 · Cited by 498
Gas-bubble lesions in stranded cetaceans
Jepson, P. D., Arbelo, M., Deaville, R., Patterson, I. A. P., Castro, P., Baker, J. R., Degollada, E., Ross, H. M., Herráez, P., Pocknell, A. M., et al. (2003) · Nature · doi:10.1038/425575a · Cited by 432
Molecular Dynamics Simulations of Hydrophilic Pores in Lipid Bilayers
Leontiadou, H., Mark, A. E., & Marrink, S. J. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74275-7 · Cited by 308
Lung damage from exposure to pulsed ultrasound
Child, S. Z., Hartman, C. L., Schery, L. A., & Carstensen, E. L. (1990) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(90)90046-f · Cited by 214
Current status of research on biophysical effects of ultrasound
Barnett, S. B., Ter Haar, G. R., Ziskin, M. C., Nyborg, W. L., Maeda, K., & Bang, J. (1994) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(94)90060-4 · Cited by 206
Rationale and derivation of MI and TI—a review
Abbott, J. G. (1999) · Ultrasound in Medicine & Biology · doi:10.1016/s0301-5629(98)00172-0 · Cited by 202
Ultrasound Enhances Reporter Gene Expression After Transfection of Vascular Cells In Vitro
Lawrie, A., Brisken, A. F., Francis, S. E., Tayler, D. I., Chamberlain, J., Crossman, D. C., Cumberland, D. C., & Newman, C. M. (1999) · Circulation · doi:10.1161/01.cir.99.20.2617 · Cited by 187
Crum, L. A., & Mao, Y. (1996) · The Journal of the Acoustical Society of America · doi:10.1121/1.414859 · Cited by 90
Low-intensity ultrasound induces angiogenesis in rat hind-limb ischemia
Barzelai, S., Sharabani‐Yosef, O., Holbová, R., Castel, D., Walden, R., Engelberg, S., & Scheinowitz, M. (2005) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2005.08.010 · Cited by 79
Acoustically induced shear stresses in the vicinity of microbubbles in tissue
Lewin, P. A., & rno, L. B. (1982) · The Journal of the Acoustical Society of America · doi:10.1121/1.387549 · Cited by 63
Cellular Alterations in Cultured Endothelial Cells Exposed to Therapeutic Ultrasound Irradiation
Raz, D., Zaretsky, U., Einav, S., & Elad, D. (2005) · Endothelium · doi:10.1080/10623320500227317 · Cited by 32
Cited by
Transcranial focused ultrasound modulates the activity of primary somatosensory cortex in humans
Legon, W., Sato, T. F., Opitz, A., Mueller, J., Barbour, A., Williams, A., & Tyler, W. J. (2014) · Nature Neuroscience · doi:10.1038/nn.3620 · Cited by 981
Qian, X., Zheng, Y., & Chen, Y. (2016) · Advanced Materials · doi:10.1002/adma.201602012 · Cited by 882
Yoo, S., Mittelstein, D. R., Hurt, R. C., Lacroix, J., & Shapiro, M. G. (2022) · Nature Communications · doi:10.1038/s41467-022-28040-1 · Cited by 492
Effective Parameters for Ultrasound-Induced In Vivo Neurostimulation
King, R. L., Brown, J. R., Newsome, W. T., & Pauly, K. B. (2013) · Ultrasound in Medicine & Biology · doi:10.1016/j.ultrasmedbio.2012.09.009 · Cited by 491
State-of-the-art materials for ultrasound-triggered drug delivery
Sirsi, S. R., & Borden, M. A. (2014) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2013.12.010 · Cited by 488
Metadata
- Authors
- Krasovitski, B., Frenkel, V., Shoham, S., & Kimmel, E.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-02-07
- Volume
- 108
- Issue
- 8
- Pages
- 3258-3263
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2014840564
- Cited by
- 550
- References
- 20
- FWCI
- 13.67
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.