The DOI matches its Crossref record; 83 of the 83 references it cites were found in a registry or an index.
Focused ultrasound excites cortical neurons via mechanosensitive calcium accumulation and ion channel amplification
Open accessAbstract
Ultrasonic neuromodulation has the unique potential to provide non-invasive control of neural activity in deep brain regions with high spatial precision and without chemical or genetic modification. However, the biomolecular and cellular mechanisms by which focused ultrasound excites mammalian neurons have remained unclear, posing significant challenges for the use of this technology in research and potential clinical applications. Here, we show that focused ultrasound excites primary murine cortical neurons in culture through a primarily mechanical mechanism mediated by specific calcium-selective mechanosensitive ion channels. The activation of these channels results in a gradual build-up of calcium, which is amplified by calcium- and voltage-gated channels, generating a burst firing response. Cavitation, temperature changes, large-scale deformation, and synaptic transmission are not required for this excitation to occur. Pharmacological and genetic inhibition of specific ion channels leads to reduced responses to ultrasound, while over-expressing these channels results in stronger ultrasonic stimulation. These findings provide a mechanistic explanation for the effect of ultrasound on neurons to facilitate the further development of ultrasonic neuromodulation and sonogenetics as tools for neuroscience research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Calcium's Role in Mechanotransduction during Muscle Development
Benavides Damm, T., & Egli, M. (2014) · Cellular Physiology and Biochemistry · doi:10.1159/000356667 · Cited by 14,502
Genome engineering using the CRISPR-Cas9 system
Ran, F. A., Hsu, P. D., Wright, J., Agarwala, V., Scott, D. A., & Zhang, F. (2013) · Nature Protocols · doi:10.1038/nprot.2013.143 · Cited by 11,133
Ultrasensitive fluorescent proteins for imaging neuronal activity
Chen, T.-W., Wardill, T. J., Sun, Y., Pulver, S. R., Renninger, S. L., Baohan, A., Schreiter, E. R., Kerr, R. A., Orger, M. B., Jayaraman, V., et al. (2013) · Nature · doi:10.1038/nature12354 · Cited by 6,474
Improved vectors and genome-wide libraries for CRISPR screening
Sanjana, N. E., Shalem, O., & Zhang, F. (2014) · Nature Methods · doi:10.1038/nmeth.3047 · Cited by 5,239
Optimized sgRNA design to maximize activity and minimize off-target effects of CRISPR-Cas9
Doench, J. G., Fusi, N., Sullender, M., Hegde, M., Vaimberg, E. W., Donovan, K. F., Smith, I., Tothova, Z., Wilen, C., Orchard, R., et al. (2016) · Nature Biotechnology · doi:10.1038/nbt.3437 · Cited by 4,637
Easy quantitative assessment of genome editing by sequence trace decomposition
Brinkman, E. K., Chen, T., Amendola, M., & van Steensel, B. (2014) · Nucleic Acids Research · doi:10.1093/nar/gku936 · Cited by 2,390
Effects of cytochalasin and phalloidin on actin.
Cooper, J. A. (1987) · The Journal of cell biology · doi:10.1083/jcb.105.4.1473 · Cited by 2,009
Diffusion: Mass Transfer in Fluid Systems
Cussler, E. L. (2009) · Cambridge University Press eBooks · doi:10.1017/cbo9780511805134 · Cited by 1,356
Ha, T., Enderle, T., Ogletree, D. F., Chemla, D. S., Selvin, P. R., & Weiss, S. (1996) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.93.13.6264 · Cited by 1,242
Acoustofluidics 7: The acoustic radiation force on small particles
Bruus, H. (2012) · Lab on a Chip · doi:10.1039/c2lc21068a · Cited by 1,019
Cited by
Spinal cord injury: molecular mechanisms and therapeutic interventions
Hu, X., Xu, W., Ren, Y., Wang, Z., He, X., Huang, R., Ma, B., Zhao, J., Zhu, R., & Cheng, L. (2023) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-023-01477-6 · Cited by 770
Ultrasound-assisted tissue engineering
Melde, K., Athanassiadis, A. G., Missirlis, D., Shi, M., Seneca, S., & Fischer, P. (2024) · Nature Reviews Bioengineering · doi:10.1038/s44222-024-00166-5 · Cited by 59
The Emergence of Functional Ultrasound for Noninvasive Brain–Computer Interface
Zheng, H., Niu, L., Qiu, W., Liang, D., Long, X., Li, G., Liu, Z., & Meng, L. (2023) · Research · doi:10.34133/research.0200 · Cited by 27
Rouhi, N., Chakeri, Z., Ghorbani Nejad, B., Rahimzadegan, M., Rafi Khezri, M., Kamali, H., & Nosrati, R. (2024) · Heliyon · doi:10.1016/j.heliyon.2024.e37533 · Cited by 20
Metadata
- Authors
- Yoo, S., Mittelstein, D. R., Hurt, R. C., Lacroix, J., & Shapiro, M. G.
- Venue
- Nature Communications
- Published
- 2022-01-25
- Volume
- 13
- Issue
- 1
- Pages
- 493-493
- ISSN
- 2041-1723 (ISSN-L)
- OpenAlex
- W4210378358
- Cited by
- 492
- References
- 83
- FWCI
- 26.24
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Focused ultrasound excites cortical neurons via mechanosensitive calcium accumulation and ion channel amplification. https://app.cochat.ai/papers/10.1038/s41467-022-28040-1
- The paper
- Yoo, S., Mittelstein, D. R., Hurt, R. C., Lacroix, J., & Shapiro, M. G. (2022). Focused ultrasound excites cortical neurons via mechanosensitive calcium accumulation and ion channel amplification. Nature Communications. https://doi.org/10.1038/s41467-022-28040-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.