The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Measuring single-cell density
Open accessAbstract
We have used a microfluidic mass sensor to measure the density of single living cells. By weighing each cell in two fluids of different densities, our technique measures the single-cell mass, volume, and density of approximately 500 cells per hour with a density precision of 0.001 g mL -1 . We observe that the intrinsic cell-to-cell variation in density is nearly 100-fold smaller than the mass or volume variation. As a result, we can measure changes in cell density indicative of cellular processes that would be otherwise undetectable by mass or volume measurements. Here, we demonstrate this with four examples: identifying Plasmodium falciparum malaria-infected erythrocytes in a culture, distinguishing transfused blood cells from a patient’s own blood, identifying irreversibly sickled cells in a sickle cell patient, and identifying leukemia cells in the early stages of responding to a drug treatment. These demonstrations suggest that the ability to measure single-cell density will provide valuable insights into cell state for a wide range of biological processes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human Malaria Parasites in Continuous Culture
Trager, W., & Jensen, J. B. (1976) · Science · doi:10.1126/science.781840 · Cited by 7,844
(1985) · Annals of Internal Medicine · doi:10.7326/0003-4819-103-3-486_3 · Cited by 2,056
Biomechanics and biophysics of cancer cells☆
SURESH, S. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.04.002 · Cited by 1,284
Self-citationWeighing of biomolecules, single cells and single nanoparticles in fluid
Burg, T. P., Godin, M., Knudsen, S. M., Shen, W., Carlson, G., Foster, J. S., Babcock, K., & Manalis, S. R. (2007) · Nature · doi:10.1038/nature05741 · Cited by 1,213
Self-citationSuresh, S., Spatz, J., Mills, J. P., Micoulet, A., Dao, M., Lim, C. T., Beil, M., & Seufferlein, T. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2004.09.001 · Cited by 878
Self-citationMaeno, E., Ishizaki, Y., Kanaseki, T., Hazama, A., & Okada, Y. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.140216197 · Cited by 707
HL-60 cells induced to differentiate towards neutrophils subsequently die via apoptosis
MARTIN, S. J., BRADLEY, J. G., & COTTER, T. G. (2008) · Clinical and Experimental Immunology · doi:10.1111/j.1365-2249.1990.tb08110.x · Cited by 381
Measurement of mass, density, and volume during the cell cycle of yeast
Bryan, A. K., Goranov, A., Amon, A., & Manalis, S. R. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0901851107 · Cited by 278
Self-citationBertles, J. F., & Milner, P. F. A. (1968) · Journal of Clinical Investigation · doi:10.1172/jci105863 · Cited by 261 · cited 2×
“The widening of the distribution of erythrocyte densities in sickle cell anemia is consistent with other studies (6), with themore-dense cells likely representing irreversibly sickled cells (15).”
ResultGray, F. D. (1988) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1988.03410110138051 · Cited by 257
Wyllie, A. H., & Morris, R. G. (1982) · PubMed · Cited by 245
Mills, J. P., Diez-Silva, M., Quinn, D. J., Dao, M., Lang, M. J., Tan, K. S. W., Lim, C. T., Milon, G., David, P. H., Mercereau-Puijalon, O., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0703433104 · Cited by 206
Self-citationGodin, M., Bryan, A. K., Burg, T. P., Babcock, K., & Manalis, S. R. (2007) · Applied Physics Letters · doi:10.1063/1.2789694 · Cited by 204
Self-citationBortner, C. D., & Cidlowski, J. A. (2004) · Pflügers Archiv - European Journal of Physiology · doi:10.1007/s00424-004-1266-5 · Cited by 157
Steiner, M. E., Assmann, S. F., Levy, J. H., Marshall, J. C., Pulkrabek, S. M., Sloan, S. R., Triulzi, D. J., & Stowell, C. P. (2010) · Transfusion and Apheresis Science · doi:10.1016/j.transci.2010.05.014 · Cited by 124
Cytoplasmic condensation is both necessary and sufficient to induce apoptotic cell death
Ernest, N. J., Habela, C. W., & Sontheimer, H. W. (2008) · Journal of Cell Science · doi:10.1242/jcs.017343 · Cited by 82
SEPARATION OF H E L A CELLS BY COLLOIDAL SILICA DENSITY GRADIENT CENTRIFUGATION
WOLFF, D. A., & Pertoft, H. (1972) · The Journal of Cell Biology · doi:10.1083/jcb.55.3.579 · Cited by 80
Cell heterogeneity in sickle cell disease: quantitation of the erythrocyte density profile.
Rodgers, G. P., Schechter, A. N., & Ct, N. (1985) · PubMed · Cited by 64
Maric, D., Marić, I., & Barker, J. L. (1998) · Methods · doi:10.1006/meth.1998.0682 · Cited by 38
Cited by
A nanomechanical mass sensor with yoctogram resolution
Chaste, J., Eichler, A., Moser, J., Ceballos, G., Rurali, R., & Bachtold, A. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.42 · Cited by 1,034
Biosensors based on nanomechanical systems
Tamayo, J., Kosaka, P. M., Ruz, J. J., San Paulo, Á., & Calleja, M. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35293a · Cited by 391
Recent advances in microfluidic techniques for single-cell biophysical characterization
Zheng, Y., Nguyen, J., Wei, Y., & Sun, Y. (2013) · Lab on a Chip · doi:10.1039/c3lc50355k · Cited by 267
Live-cell mass profiling: an emerging approach in quantitative biophysics
Zangle, T. A., & Teitell, M. A. (2014) · Nature Methods · doi:10.1038/nmeth.3175 · Cited by 260
Chip in a lab: microfluidics for next generation life science research
Streets, A. M., & Huang, Y. (2013) · Biomicrofluidics · doi:10.1063/1.4789751 · Cited by 180
Metadata
- Authors
- Grover, W. H., Bryan, A. K., Diez-Silva, M., Suresh, S., Higgins, J. M., & Manalis, S. R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-06-20
- Volume
- 108
- Issue
- 27
- Pages
- 10992-10996
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1986349994
- Cited by
- 355
- References
- 19
- FWCI
- 11.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.