Measuring single-cell density
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
We have used a microfluidic mass sensor to measure the density of single living cells. By weighing each cell in two fluids of different densities, our technique measures the single-cell mass, volume, and density of approximately 500 cells per hour with a density precision of 0.001 g mL -1 . We observe that the intrinsic cell-to-cell variation in density is nearly 100-fold smaller than the mass or volume variation. As a result, we can measure changes in cell density indicative of cellular processes that would be otherwise undetectable by mass or volume measurements. Here, we demonstrate this with four examples: identifying Plasmodium falciparum malaria-infected erythrocytes in a culture, distinguishing transfused blood cells from a patient’s own blood, identifying irreversibly sickled cells in a sickle cell patient, and identifying leukemia cells in the early stages of responding to a drug treatment. These demonstrations suggest that the ability to measure single-cell density will provide valuable insights into cell state for a wide range of biological processes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Human Malaria Parasites in Continuous Culture
Trager, W., & Jensen, J. B. (1976) · Science · doi:10.1126/science.781840 · Cited by 7,844
(1985) · Annals of Internal Medicine · doi:10.7326/0003-4819-103-3-486_3 · Cited by 2,056
Biomechanics and biophysics of cancer cells☆
SURESH, S. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.04.002 · Cited by 1,284 · cited 1×
“Methods for measuring fundamental biomechanical and biophysical attributes of single cells have consistently provided valuable insights into cell biology (19, 20), and we anticipate that density, a fundamental property of all cells, will similarly prove to be useful for identifying, distinguishing, and studying single…”
BackgroundSelf-citationWeighing of biomolecules, single cells and single nanoparticles in fluid
Burg, T. P., Godin, M., Knudsen, S. M., Shen, W., Carlson, G., Foster, J. S., Babcock, K., & Manalis, S. R. (2007) · Nature · doi:10.1038/nature05741 · Cited by 1,213 · cited 1×
“The “balance” we use to weigh cells in two different fluids is the suspended microchannel resonator (SMR), a microfabricated microfluidic mass sensor (9).”
MethodSelf-citationSuresh, S., Spatz, J., Mills, J. P., Micoulet, A., Dao, M., Lim, C. T., Beil, M., & Seufferlein, T. (2005) · Acta Biomaterialia · doi:10.1016/j.actbio.2004.09.001 · Cited by 878
Self-citationMaeno, E., Ishizaki, Y., Kanaseki, T., Hazama, A., & Okada, Y. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.140216197 · Cited by 707
HL-60 cells induced to differentiate towards neutrophils subsequently die via apoptosis
MARTIN, S. J., BRADLEY, J. G., & COTTER, T. G. (2008) · Clinical and Experimental Immunology · doi:10.1111/j.1365-2249.1990.tb08110.x · Cited by 381
Measurement of mass, density, and volume during the cell cycle of yeast
Bryan, A. K., Goranov, A., Amon, A., & Manalis, S. R. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0901851107 · Cited by 278 · cited 1×
“Previous work with the SMR showed that the average density of a population of cells can be calculated from buoyant mass measurements (10, 11) and that yeast exhibit cell cycle-dependent variations in average cell density (11), but these methods cannot measure the density of single cells or derive statistics about the…”
BackgroundSelf-citationBertles, J. F., & Milner, P. F. A. (1968) · Journal of Clinical Investigation · doi:10.1172/jci105863 · Cited by 261 · cited 2×
“The widening of the distribution of erythrocyte densities in sickle cell anemia is consistent with other studies (6), with themore-dense cells likely representing irreversibly sickled cells (15).”
ResultGray, F. D. (1988) · JAMA: The Journal of the American Medical Association · doi:10.1001/jama.1988.03410110138051 · Cited by 257
Cited by
A nanomechanical mass sensor with yoctogram resolution
Chaste, J., Eichler, A., Moser, J., Ceballos, G., Rurali, R., & Bachtold, A. (2012) · Nature Nanotechnology · doi:10.1038/nnano.2012.42 · Cited by 1,034
Biosensors based on nanomechanical systems
Tamayo, J., Kosaka, P. M., Ruz, J. J., San Paulo, Á., & Calleja, M. (2013) · Chem. Soc. Rev. · doi:10.1039/c2cs35293a · Cited by 391
Recent advances in microfluidic techniques for single-cell biophysical characterization
Zheng, Y., Nguyen, J., Wei, Y., & Sun, Y. (2013) · Lab on a Chip · doi:10.1039/c3lc50355k · Cited by 267
Live-cell mass profiling: an emerging approach in quantitative biophysics
Zangle, T. A., & Teitell, M. A. (2014) · Nature Methods · doi:10.1038/nmeth.3175 · Cited by 260
Size control in mammalian cells involves modulation of both growth rate and cell cycle duration
Cadart, C., Monnier, S., Grilli, J., Sáez, P. J., Srivastava, N., Attia, R., Terriac, E., Baum, B., Cosentino-Lagomarsino, M., & Piel, M. (2018) · Nature Communications · doi:10.1038/s41467-018-05393-0 · Cited by 239
Microfluidic single cell analysis: from promise to practice
Lecault, V., White, A. K., Singhal, A., & Hansen, C. L. (2012) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2012.03.022 · Cited by 229
“This technique was used to show that heavier cells grew faster than lighter cells [77], and that cellular density could be used to distinguish subpopulations of blood cells [78].”
MethodChip in a lab: microfluidics for next generation life science research
Streets, A. M., & Huang, Y. (2013) · Biomicrofluidics · doi:10.1063/1.4789751 · Cited by 180
From the Bench to the Field in Low‐Cost Diagnostics: Two Case Studies
Kumar, A. A., Hennek, J. W., Smith, B. S., Kumar, S., Beattie, P., Jain, S., Rolland, J. P., Stossel, T. P., Chunda‐Liyoka, C., & Whitesides, G. M. (2015) · Angewandte Chemie International Edition · doi:10.1002/anie.201411741 · Cited by 163
Probing Red Blood Cell Morphology Using High-Frequency Photoacoustics
Strohm, E. M., Berndl, E. S. L., & Kolios, M. C. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2013.05.037 · Cited by 159
Cell size is a determinant of stem cell potential during aging
Lengefeld, J., Cheng, C.-W., Maretich, P., Blair, M., Hagen, H., McReynolds, M. R., Sullivan, E., Majors, K., Roberts, C., Kang, J. H., et al. (2021) · Science Advances · doi:10.1126/sciadv.abk0271 · Cited by 159
Self-citationPatra, B., Chen, Y.-H., Peng, C.-C., Lin, S.-C., Lee, C.-H., & Tung, Y.-C. (2013) · Biomicrofluidics · doi:10.1063/1.4824480 · Cited by 109
Characterizing Cellular Biophysical Responses to Stress by Relating Density, Deformability, and Size
Byun, S., Hecht, V. C., & Manalis, S. R. (2015) · Biophysical Journal · doi:10.1016/j.bpj.2015.08.038 · Cited by 34
Self-citationConserved nucleocytoplasmic density homeostasis drives cellular organization across eukaryotes
Biswas, A., Muñoz, O., Kim, K., Hoege, C., Lorton, B. M., Shechter, D., Guck, J., Zaburdaev, V., & Reber, S. (2023) · doi:10.1101/2023.09.05.556409 · Cited by 31
Metadata
- Authors
- Grover, W. H., Bryan, A. K., Diez-Silva, M., Suresh, S., Higgins, J. M., & Manalis, S. R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-06-20
- Volume
- 108
- Issue
- 27
- Pages
- 10992-10996
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1986349994
- Cited by
- 355
- References
- 19
- FWCI
- 11.49
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.