Compact and flexible raster scanning multiphoton endoscope capable of imaging unstained tissue
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
We present a compact and flexible endoscope (3-mm outer diameter, 4-cm rigid length) that utilizes a miniaturized resonant/nonresonant fiber raster scanner and a multielement gradient-index lens assembly for two-photon excited intrinsic fluorescence and second-harmonic generation imaging of biological tissues. The miniaturized raster scanner is fabricated by mounting a commercial double-clad optical fiber (DCF) onto two piezo bimorphs that are aligned such that their bending axes are perpendicular to each other. Fast lateral scanning of the laser illumination at 4.1 frames/s (512 lines per frame) is achieved by simultaneously driving the DCF cantilever at its resonant frequency in one dimension and nonresonantly in the orthogonal axis. The implementation of a DCF into the scanner enables simultaneous delivery of the femtosecond pulsed 800-nm excitation source and epi-collection of the signal. Our device is able to achieve a field-of-view (FOV xy ) of 110 μm by 110 μm with a highly uniform pixel dwell time. The lateral and axial resolutions for two-photon imaging are 0.8 and 10 μm, respectively. The endoscope’s imaging capabilities were demonstrated by imaging ex vivo mouse tissue through the collection of intrinsic fluorescence and second-harmonic signal without the need for staining. The results presented here indicate that our device can be applied in the future to perform minimally invasive in vivo optical biopsies for medical diagnostics.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cancer Cell Imaging and Photothermal Therapy in the Near-Infrared Region by Using Gold Nanorods
Huang, X., El-Sayed, I. H., Qian, W., & El-Sayed, M. A. (2006) · Journal of the American Chemical Society · doi:10.1021/ja057254a · Cited by 5,436
Zipfel, W. R., Williams, R. M., Christie, R., Nikitin, A. Y., Hyman, B. T., & Webb, W. W. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0832308100 · Cited by 1,676
Self-citationA Miniature Head-Mounted Two-Photon Microscope
Helmchen, F., Fee, M. S., Tank, D. W., & Denk, W. (2001) · Neuron · doi:10.1016/s0896-6273(01)00421-4 · Cited by 622
Ultra-compact fiber-optic two-photon microscope for functional fluorescence imaging in vivo
Engelbrecht, C. J., Johnston, R. S., Seibel, E. J., & Helmchen, F. (2008) · Optics Express · doi:10.1364/oe.16.005556 · Cited by 279
Discrimination of basal cell carcinoma from normal dermal stroma by quantitative multiphoton imaging
Lin, S.-J., Jee, S.-H., Kuo, C.-J., Wu, R.-J., Lin, W.-C., Chen, J.-S., Liao, Y.-H., Hsu, C.-J., Tsai, T.-F., Chen, Y.-F., et al. (2006) · Optics Letters · doi:10.1364/ol.31.002756 · Cited by 184
Piyawattanametha, W., Cocker, E. D., Burns, L. D., Barretto, R. P. J., Jung, J. C., Ra, H., Solgaard, O., & Schnitzer, M. J. (2009) · Optics Letters · doi:10.1364/ol.34.002309 · Cited by 180
Wu, Y., Leng, Y., Xi, J., & Li, X. D. (2009) · Optics Express · doi:10.1364/oe.17.007907 · Cited by 173
Piyawattanametha, W., Barretto, R. P. J., Ko, T. H., Flusberg, B. A., Cocker, E. D., Ra, H., Lee, D., Solgaard, O., & Schnitzer, M. J. (2006) · Optics Letters · doi:10.1364/ol.31.002018 · Cited by 158
Tang, S., Jung, W., McCormick, D. T., Xie, T., Su, J., Ahn, Y., Tromberg, B. J., & Chen, Z. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3127203 · Cited by 122
MPScope: A versatile software suite for multiphoton microscopy
Nguyen, Q.-T., Tsai, P. S., & Kleinfeld, D. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.03.001 · Cited by 104
Goetz, M., Fottner, C., Schirrmacher, E., Delaney, P., Gregor, S., Schneider, C., Strand, D., Kanzler, S., Memadathil, B., Weyand, E., et al. (2007) · Endoscopy · doi:10.1055/s-2007-966262 · Cited by 83
Miniature random-access fiber scanner for in vivo multiphoton imaging
Sawinski, J., & Denk, W. T. (2007) · Journal of Applied Physics · doi:10.1063/1.2763945 · Cited by 82
Three-dimensional nonlinear optical endoscopy
Fu, L., Jain, A., Cranfield, C. G., Xie, H., & Gu, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2756102 · Cited by 81
Differentiation of normal and cancerous lung tissues by multiphoton imaging
Wang, C., Li, F., Wu, R.-J., Hovhannisyan, V., Lin, W., Lin, S., So, P. T. C., & Dong, C. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3210768 · Cited by 63
In vivo multiphoton fluorescence imaging: A novel approach to oral malignancy
Wilder-Smith, P. B. B., Osann, K., Hanna, N. M., El-Abbadi, N., Brenner, M., Messadi, D. V., & Krasieva, T. B. (2004) · Lasers in Surgery and Medicine · doi:10.1002/lsm.20079 · Cited by 62
Feasibility of using multiphoton excited tissue autofluorescence for in vivo human histopathology
Cruz, J. M. D., McMullen, J. D., Williams, R. M., & Zipfel, W. R. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.001320 · Cited by 51
Multiphoton microscopy as a diagnostic imaging modality for lung cancer
Pavlova, I., Hume, K. R., Yazinski, S. A., Peters, R. M., Weiss, R. S., & Webb, W. W. (2010) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.841017 · Cited by 30
Self-citationTunable dispersion compensation by a rotating cylindrical lens
Durst, M. E., Kobat, D., & Xu, C. (2009) · Optics Letters · doi:10.1364/ol.34.001195 · Cited by 23
Self-citation
Cited by
Brain Tissue Responses to Neural Implants Impact Signal Sensitivity and Intervention Strategies
Kozai, T. D. Y., Jaquins-Gerstl, A. S., Vazquez, A. L., Michael, A. C., & Cui, X. T. (2015) · ACS Chemical Neuroscience · doi:10.1021/cn500256e · Cited by 622
Scanner-Free and Wide-Field Endoscopic Imaging by Using a Single Multimode Optical Fiber
Choi, Y., Yoon, C., Kim, M., Yang, T. D., Fang-Yen, C., Dasari, R. R., Lee, K. J., & Choi, W. (2012) · Physical Review Letters · doi:10.1103/physrevlett.109.203901 · Cited by 619
Fast high-resolution miniature two-photon microscopy for brain imaging in freely behaving mice
Zong, W., Wu, R., Li, M., Hu, Y., Li, Y., Li, J., Rong, H., Wu, H., Xu, Y., Lu, Y., et al. (2017) · Nature Methods · doi:10.1038/nmeth.4305 · Cited by 513
In vivo imaging of neural activity
Yang, W., & Yuste, R. (2017) · Nature Methods · doi:10.1038/nmeth.4230 · Cited by 406
High-resolution, lensless endoscope based on digital scanning through a multimode optical fiber
Papadopoulos, I. N., Farahi, S., Moser, C., & Psaltis, D. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.000260 · Cited by 345
Metadata
- Authors
- Rivera, D. R., Brown, C. M., Ouzounov, D. G., Pavlova, I., Kobat, D., Webb, W. W., & Xu, C.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-10-17
- Volume
- 108
- Issue
- 43
- Pages
- 17598-17603
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1995841068
- Cited by
- 274
- References
- 18
- FWCI
- 15.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.