The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Superpenetration optical microscopy by iterative multiphoton adaptive compensation technique
Open accessAbstract
Biological tissues are rarely transparent, presenting major challenges for deep tissue optical microscopy. The achievable imaging depth is fundamentally limited by wavefront distortions caused by aberration and random scattering. Here, we report an iterative wavefront compensation technique that takes advantage of the nonlinearity of multiphoton signals to determine and compensate for these distortions and to focus light inside deep tissues. Different from conventional adaptive optics methods, this technique can rapidly measure highly complicated wavefront distortions encountered in deep tissue imaging and provide compensations for not only aberration but random scattering. The technique is tested with a variety of highly heterogeneous biological samples including mouse brain tissue, skull, and lymph nodes. We show that high quality three-dimensional imaging can be realized at depths beyond the reach of conventional multiphoton microscopy and adaptive optics methods, albeit over restricted distances for a given correction. Moreover, the required laser excitation power can be greatly reduced in deep tissues, deviating from the power requirement of ballistic light excitation and thus significantly reducing photo damage to the biological tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles of two-photon excitation microscopy and its applications to neuroscience
Svoboda, K., & Yasuda, R. (2006) · Neuron · doi:10.1016/j.neuron.2006.05.019 · Cited by 1,027
Cited by
Katz, O., Heidmann, P., Fink, M., & Gigan, S. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.189 · Cited by 1,157
Advanced CLARITY for rapid and high-resolution imaging of intact tissues
Tomer, R., Ye, L., Hsueh, B., & Deisseroth, K. (2014) · Nature Protocols · doi:10.1038/nprot.2014.123 · Cited by 842
Light fields in complex media: Mesoscopic scattering meets wave control
Rotter, S., & Gigan, S. (2017) · Reviews of Modern Physics · doi:10.1103/revmodphys.89.015005 · Cited by 654
Guidestar-assisted wavefront-shaping methods for focusing light into biological tissue
Horstmeyer, R., Ruan, H., & Yang, C. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.140 · Cited by 651
Adaptive optical microscopy: the ongoing quest for a perfect image
Booth, M. J. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.46 · Cited by 645
Metadata
- Authors
- Tang, J., Germain, R. N., & Cui, M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-05-14
- Volume
- 109
- Issue
- 22
- Pages
- 8434-8439
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2020537642
- Cited by
- 236
- References
- 1
- FWCI
- 8.29
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Superpenetration optical microscopy by iterative multiphoton adaptive compensation technique. https://app.cochat.ai/papers/10.1073/pnas.1119590109
- The paper
- Tang, J., Germain, R. N., & Cui, M. (2012). Superpenetration optical microscopy by iterative multiphoton adaptive compensation technique. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1119590109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.