Heart wall myofibers are arranged in minimal surfaces to optimize organ function
Open accessThe DOI matches its Crossref record; 39 of the 40 references it cites were found in a registry or an index.
Abstract
Heart wall myofibers wind as helices around the ventricles, strengthening them in a manner analogous to the reinforcement of concrete cylindrical columns by spiral steel cables [Richart FE, et al. (1929) Univ of Illinois, Eng Exp Stn Bull 190]. A multitude of such fibers, arranged smoothly and regularly, contract and relax as an integrated functional unit as the heart beats. To orchestrate this motion, fiber tangling must be avoided and pumping should be efficient. Current models of myofiber orientation across the heart wall suggest groupings into sheets or bands, but the precise geometry of bundles of myofibers is unknown. Here we show that this arrangement takes the form of a special minimal surface, the generalized helicoid [Blair DE, Vanstone JR (1978) Minimal Submanifolds and Geodesics 13–16], closing the gap between individual myofibers and their collective wall structure. The model holds across species, with a smooth variation in its three curvature parameters within the myocardial wall providing tight fits to diffusion magnetic resonance images from the rat, the dog, and the human. Mathematically it explains how myofibers are bundled in the heart wall while economizing fiber length and optimizing ventricular ejection volume as they contract. The generalized helicoid provides a unique foundation for analyzing the fibrous composite of the heart wall and should therefore find applications in heart tissue engineering and in the study of heart muscle diseases.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The myocardial ECM is fibrillar, anisotropic, and provides nanotopographical cues that guide cardiomyocyte alignment and assembly44, ultimately forming a helicoid structure that optimizes ejection fraction during ventricular contraction45.”
From A tissue-engineered scale model of the heart ventricle (2018) · cites this paper as [45]
Citations
Cites
Fisher, R. (1953) · Proceedings of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rspa.1953.0064 · Cited by 5,563
Fiber Orientation in the Canine Left Ventricle during Diastole and Systole
STREETER, D. D., SPOTNITZ, H. M., PATEL, D. P., ROSS, J., & SONNENBLICK, E. H. (1969) · Circulation Research · doi:10.1161/01.res.24.3.339 · Cited by 1,454
Optimal strategies for measuring diffusion in anisotropic systems by magnetic resonance imaging
Jones, D. K., Horsfield, M. A., & Simmons, A. (1999) · Magnetic Resonance in Medicine · doi:10.1002/(sici)1522-2594(199909)42:3<515::aid-mrm14>3.0.co;2-q · Cited by 1,403
Osserman, R. (1969) · CERN Document Server (European Organization for Nuclear Research) · Cited by 998
LeGrice, I. J., Smaill, B. H., Chai, L. Z., Edgar, S. G., Gavin, J. B., & Hunter, P. J. (1995) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1995.269.2.h571 · Cited by 842
Twisted fibrous arrangements in biological materials and cholesteric mesophases
Bouligand, Y. (1972) · Tissue and Cell · doi:10.1016/s0040-8166(72)80042-9 · Cited by 818
Distance transformations in arbitrary dimensions
Borgefors, G. (1984) · Computer Vision, Graphics, and Image Processing · doi:10.1016/0734-189x(84)90035-5 · Cited by 779
Mathematical model of geometry and fibrous structure of the heart
Nielsen, P. M., Le Grice, I. J., Smaill, B. H., & Hunter, P. J. (1991) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.1991.260.4.h1365 · Cited by 657
Mathematical aspects of heart physiology
Peskin, C. S. (1975) · Courant Institute of Mathematical Sciences, New York University eBooks · Cited by 614
Diffusion MRI: Theory, methods, and applications
Jones, D. K. (2011) · Cited by 444
Research works printed but not linked: 2
- DE Blair, JR Vanstone, A generalization of the helicoid. Minimal Submanifolds and Geodesics (Kaigai Publ, Tokyo), pp. 13–16 (1978).
- JJ Nitsche Lectures on Minimal Surfaces: Volume 1, Introduction, Fundamentals, Geometry and Basic Boundary Value Problems (Cambridge Univ Press, Cambridge, UK, 1989).
Cited by
The Relationship Between the Right Ventricle and its Load in Pulmonary Hypertension
Vonk Noordegraaf, A., Westerhof, B. E., & Westerhof, N. (2017) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.10.047 · Cited by 780
“New techniques under development to measure fiber orientation in the ventricular wall (56) and to derive wall stiffness, such as ultrasound-based elastography (57) are promising, but have not yet been applied in the context of PH.”
MethodGuidelines for measuring cardiac physiology in mice
Lindsey, M. L., Kassiri, Z., Virag, J. A. I., de Castro Brás, L. E., & Scherrer-Crosbie, M. (2018) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00339.2017 · Cited by 349
A tissue-engineered scale model of the heart ventricle
MacQueen, L. A., Sheehy, S. P., Chantre, C. O., Zimmerman, J. F., Pasqualini, F. S., Liu, X., Goss, J. A., Campbell, P. H., Gonzalez, G. M., Park, S.-J., et al. (2018) · Nature Biomedical Engineering · doi:10.1038/s41551-018-0271-5 · Cited by 227
Fibrous scaffolds for building hearts and heart parts
Capulli, A. K., MacQueen, L. A., Sheehy, S. P., & Parker, K. K. (2016) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.11.020 · Cited by 130
Papadacci, C., Finel, V., Provost, J., Villemain, O., Bruneval, P., Gennisson, J., Tanter, M., Fink, M., & Pernot, M. (2017) · Scientific Reports · doi:10.1038/s41598-017-00946-7 · Cited by 108
Metadata
- Authors
- Savadjiev, P., Strijkers, G. J., Bakermans, A. J., Piuze, E., Zucker, S. W., & Siddiqi, K.
- Affiliations
- Brigham and Women's Hospital (US)
- Eindhoven University of Technology (NL)
- McGill University (CA)
- Yale University (US)
- School of Computer Science and Centre for Intelligent Machines, McGill University, Montréal, Canada H3A 2A7; and
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2012-05-29
- Volume
- 109
- Issue
- 24
- Pages
- 9248-9253
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC3386057
- OpenAlex
- W2169776346
- Cited by
- 62
- References
- 40
- Citations by year
- 2024: 3 · 2023: 2 · 2022: 2 · 2021: 3 · 2020: 2 · 2019: 4 · 2018: 8 · 2017: 7 · 2016: 5 · 2015: 10 · 2014: 9 · 2013: 6 · 2012: 1
- FWCI
- 5.35
- Type
- journal article
- Language
- en
- Update notices
- correction (2012-11-12)
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- TU/e Research Portal (publishedVersion)
- TU/e Research Portal (submittedVersion)
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Physical Sciences › Engineering › Biomedical Engineering › Elasticity and Material Modeling
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiomyopathy and Myosin Studies
- Keywords
- minimal surfaces, cardiac tissue engineering, cardiomyopathy
- MeSH terms
- Animals, Dogs, Heart, Humans, Magnetic Resonance Imaging, Myocardial Contraction
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Heart wall myofibers are arranged in minimal surfaces to optimize organ function. https://app.cochat.ai/papers/10.1073/pnas.1120785109
- The paper
- Savadjiev, P., Strijkers, G. J., Bakermans, A. J., Piuze, E., Zucker, S. W., & Siddiqi, K. (2012). Heart wall myofibers are arranged in minimal surfaces to optimize organ function. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1120785109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.