The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Nanoelectrodes for determination of reactive oxygen and nitrogen species inside murine macrophages
Open accessAbstract
Reactive oxygen and nitrogen species (ROS and RNS) produced by macrophages are essential for protecting a human body against bacteria and viruses. Micrometer-sized electrodes coated with Pt black have previously been used for selective and sensitive detection of ROS and RNS in biological systems. To determine ROS and RNS inside macrophages, one needs smaller (i.e., nanometer-sized) sensors. In this article, the methodologies have been extended to the fabrication and characterization of Pt/Pt black nanoelectrodes. Electrodes with the metal surface flush with glass insulator, most suitable for quantitative voltammetric experiments, were fabricated by electrodeposition of Pt black inside an etched nanocavity under the atomic force microscope control. Despite a nanometer-scale radius, the true surface area of Pt electrodes was sufficiently large to yield stable and reproducible responses to ROS and RNS in vitro. The prepared nanoprobes were used to penetrate cells and detect ROS and RNS inside macrophages. Weak and very short leaks of ROS/RNS from the vacuoles into the cytoplasm were detected, which a macrophage is equipped to clean within a couple of seconds, while higher intensity oxidative bursts due to the emptying of vacuoles outside persist on the time scale of tens of seconds.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Antimicrobial reactive oxygen and nitrogen species: concepts and controversies
Fang, F. C. (2004) · Nature Reviews Microbiology · doi:10.1038/nrmicro1004 · Cited by 1,676
Cited by
ROS production in phagocytes: Why, when, and where?
Dupré-Crochet, S., Erard, M., & Nüβe, O. (2013) · Journal of Leukocyte Biology · doi:10.1189/jlb.1012544 · Cited by 467
De Logu, F., Nassini, R., Materazzi, S., Carvalho Gonçalves, M., Nosi, D., Rossi Degl’Innocenti, D., Marone, I. M., Ferreira, J., Li Puma, S., Benemei, S., et al. (2017) · Nature Communications · doi:10.1038/s41467-017-01739-2 · Cited by 283
Electrochemical Nanoprobes for Single-Cell Analysis
Actis, P., Tokar, S., Clausmeyer, J., Babakinejad, B., Mikhaleva, S., Cornut, R., Takahashi, Y., López Córdoba, A., Novak, P., Shevchuck, A. I., et al. (2014) · ACS Nano · doi:10.1021/nn405612q · Cited by 252
Liu, Y., Qin, Y., Jin, Z., Hu, X., Chen, M., Liu, R., Amatore, C., & Huang, W. (2017) · Angewandte Chemie International Edition · doi:10.1002/anie.201705215 · Cited by 89
Self-citationSTIM-Orai Channels and Reactive Oxygen Species in the Tumor Microenvironment
Frisch, J., Angenendt, A., Hoth, M., Prates Roma, L., & Lis, A. (2019) · Cancers · doi:10.3390/cancers11040457 · Cited by 68
Metadata
- Authors
- Wang, Y., Noël, J.-M., Velmurugan, J., Nogala, W., Mirkin, M. V., Lu, C., Guille Collignon, M., Lemaître, F., & Amatore, C.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-05-21
- Volume
- 109
- Issue
- 29
- Pages
- 11534-11539
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2149171993
- Cited by
- 229
- References
- 1
- FWCI
- 10.38
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Nanoelectrodes for determination of reactive oxygen and nitrogen species inside murine macrophages. https://app.cochat.ai/papers/10.1073/pnas.1201552109
- The paper
- Wang, Y., Noël, J.-M., Velmurugan, J., Nogala, W., Mirkin, M. V., Lu, C., Guille Collignon, M., Lemaître, F., & Amatore, C. (2012). Nanoelectrodes for determination of reactive oxygen and nitrogen species inside murine macrophages. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1201552109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.