The DOI matches its Crossref record.
Simultaneous, accurate measurement of the 3D position and orientation of single molecules
Open accessAbstract
Recently, single molecule-based superresolution fluorescence microscopy has surpassed the diffraction limit to improve resolution to the order of 20 nm or better. These methods typically use image fitting that assumes an isotropic emission pattern from the single emitters as well as control of the emitter concentration. However, anisotropic single-molecule emission patterns arise from the transition dipole when it is rotationally immobile, depending highly on the molecule’s 3D orientation and z position. Failure to account for this fact can lead to significant lateral ( x , y ) mislocalizations (up to ∼50–200 nm). This systematic error can cause distortions in the reconstructed images, which can translate into degraded resolution. Using parameters uniquely inherent in the double-lobed nature of the Double-Helix Point Spread Function, we account for such mislocalizations and simultaneously measure 3D molecular orientation and 3D position. Mislocalizations during an axial scan of a single molecule manifest themselves as an apparent lateral shift in its position, which causes the standard deviation (SD) of its lateral position to appear larger than the SD expected from photon shot noise. By correcting each localization based on an estimated orientation, we are able to improve SDs in lateral localization from ∼2× worse than photon-limited precision (48 vs. 25 nm) to within 5 nm of photon-limited precision. Furthermore, by averaging many estimations of orientation over different depths, we are able to improve from a lateral SD of 116 (∼4× worse than the photon-limited precision; 28 nm) to 34 nm (within 6 nm of the photon limit).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescence nanoscopy in cell biology
Sahl, S. J., Hell, S. W., & Jakobs, S. (2017) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.71 · Cited by 990
Self-citationStimulated Emission Depletion Microscopy
Blom, H., & Widengren, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00653 · Cited by 339
Switchable Fluorophores for Single-Molecule Localization Microscopy
Li, H., & Vaughan, J. C. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00767 · Cited by 319
Single-molecule spectroscopy and imaging over the decades
Moerner, W. E., Shechtman, Y., & Wang, Q. (2015) · Faraday Discussions · doi:10.1039/c5fd00149h · Cited by 103
Self-citation
Metadata
- Authors
- Backlund, M. P., Lew, M. D., Backer, A. S., Sahl, S. J., Grover, G., Agrawal, A., Piestun, R., & Moerner, W. E.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-11-05
- Volume
- 109
- Issue
- 47
- Pages
- 19087-19092
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2010932144
- Cited by
- 203
- References
- 0
- FWCI
- 7.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Simultaneous, accurate measurement of the 3D position and orientation of single molecules. https://app.cochat.ai/papers/10.1073/pnas.1216687109
- The paper
- Backlund, M. P., Lew, M. D., Backer, A. S., Sahl, S. J., Grover, G., Agrawal, A., Piestun, R., & Moerner, W. E. (2012). Simultaneous, accurate measurement of the 3D position and orientation of single molecules. Proceedings of the National Academy of Sciences. https://doi.org/10.1073/pnas.1216687109
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.