Simultaneous, accurate measurement of the 3D position and orientation of single molecules
Open accessThe DOI matches its Crossref record.
Abstract
Recently, single molecule-based superresolution fluorescence microscopy has surpassed the diffraction limit to improve resolution to the order of 20 nm or better. These methods typically use image fitting that assumes an isotropic emission pattern from the single emitters as well as control of the emitter concentration. However, anisotropic single-molecule emission patterns arise from the transition dipole when it is rotationally immobile, depending highly on the molecule’s 3D orientation and z position. Failure to account for this fact can lead to significant lateral ( x , y ) mislocalizations (up to ∼50–200 nm). This systematic error can cause distortions in the reconstructed images, which can translate into degraded resolution. Using parameters uniquely inherent in the double-lobed nature of the Double-Helix Point Spread Function, we account for such mislocalizations and simultaneously measure 3D molecular orientation and 3D position. Mislocalizations during an axial scan of a single molecule manifest themselves as an apparent lateral shift in its position, which causes the standard deviation (SD) of its lateral position to appear larger than the SD expected from photon shot noise. By correcting each localization based on an estimated orientation, we are able to improve SDs in lateral localization from ∼2× worse than photon-limited precision (48 vs. 25 nm) to within 5 nm of photon-limited precision. Furthermore, by averaging many estimations of orientation over different depths, we are able to improve from a lateral SD of 116 (∼4× worse than the photon-limited precision; 28 nm) to 34 nm (within 6 nm of the photon limit).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescence nanoscopy in cell biology
Sahl, S. J., Hell, S. W., & Jakobs, S. (2017) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.71 · Cited by 990
Self-citationPrecisely and accurately localizing single emitters in fluorescence microscopy
Deschout, H., Zanacchi, F. C., Mlodzianoski, M., Diaspro, A., Bewersdorf, J., Hess, S. T., & Braeckmans, K. (2014) · Nature Methods · doi:10.1038/nmeth.2843 · Cited by 498
von Diezmann, L., Shechtman, Y., & Moerner, W. E. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00629 · Cited by 491
Self-citationOptimal Point Spread Function Design for 3D Imaging
Shechtman, Y., Sahl, S. J., Backer, A. S., & Moerner, W. E. (2014) · Physical Review Letters · doi:10.1103/physrevlett.113.133902 · Cited by 384
Self-citationFluorophore localization algorithms for super-resolution microscopy
Small, A., & Stahlheber, S. (2014) · Nature Methods · doi:10.1038/nmeth.2844 · Cited by 349
Stimulated Emission Depletion Microscopy
Blom, H., & Widengren, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00653 · Cited by 339
The 2015 super-resolution microscopy roadmap
Hell, S. W., Sahl, S. J., Bates, M., Zhuang, X., Heintzmann, R., Booth, M. J., Bewersdorf, J., Shtengel, G., Hess, H., Tinnefeld, P., et al. (2015) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/48/44/443001 · Cited by 325
Self-citationSwitchable Fluorophores for Single-Molecule Localization Microscopy
Li, H., & Vaughan, J. C. (2018) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00767 · Cited by 319
Shechtman, Y., Weiss, L. E., Backer, A. S., Sahl, S. J., & Moerner, W. E. (2015) · Nano Letters · doi:10.1021/acs.nanolett.5b01396 · Cited by 270
Self-citationMulticolour localization microscopy by point-spread-function engineering
Shechtman, Y., Weiss, L. E., Backer, A. S., Lee, M. Y., & Moerner, W. E. (2016) · Nature Photonics · doi:10.1038/nphoton.2016.137 · Cited by 162
Self-citationExtending Single-Molecule Microscopy Using Optical Fourier Processing
Backer, A. S., & Moerner, W. E. (2014) · The Journal of Physical Chemistry B · doi:10.1021/jp501778z · Cited by 160
Self-citationBacklund, M. P., Lew, M. D., Backer, A. S., Sahl, S. J., & Moerner, W. E. (2014) · ChemPhysChem · doi:10.1002/cphc.201300880 · Cited by 159
Self-citationSingle-molecule spectroscopy and imaging over the decades
Moerner, W. E., Shechtman, Y., & Wang, Q. (2015) · Faraday Discussions · doi:10.1039/c5fd00149h · Cited by 103
Self-citation
Metadata
- Authors
- Backlund, M. P., Lew, M. D., Backer, A. S., Sahl, S. J., Grover, G., Agrawal, A., Piestun, R., & Moerner, W. E.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-11-05
- Volume
- 109
- Issue
- 47
- Pages
- 19087-19092
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2010932144
- Cited by
- 203
- References
- 0
- FWCI
- 7.59
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.