Conformal piezoelectric energy harvesting and storage from motions of the heart, lung, and diaphragm
Open accessThe DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Abstract
Significance: Heart rate monitors, pacemakers, cardioverter-defibrillators, and neural stimulators constitute broad classes of electronic implants that rely on battery power for operation. Means for harvesting power directly from natural processes of the body represent attractive alternatives for these and future types of biomedical devices. Here we demonstrate a complete, flexible, and integrated system that is capable of harvesting and storing energy from the natural contractile and relaxation motions of the heart, lung, and diaphragm at levels that meet requirements for practical applications. Systematic experimental evaluations in large animal models and quantitatively accurate computational models reveal the fundamental modes of operation and establish routes for further improvements.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Specifically, recent studies have demonstrated the feasibility of piezoelectric,[327] near field communication (NFC),[328] and ultrasonic technologies[329] in power supply and data transmission.”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [327]
In the citing paper
“However, these methods are anatomically specific and, in their existing forms, yield power densities too low (<0.1 μW/mm 2 ) for a microimplant.”
From Wireless power transfer to deep-tissue microimplants (2014) · cites this paper as [7]
In the citing paper
“Another piezoelectric energy harvester using the PZT ribbon is reported for scavenging the biomechanical energy from the motions of the heart, lung, and diaphragm [Fig.2(i)].70”
From From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks (2019) · cites this paper as [70]
In the citing paper
“When attached on a bovine heart, the device is able to produce an output voltage of around 4 V.”
From From flexible electronics technology in the era of IoT and artificial intelligence toward future implanted body sensor networks (2019) · cites this paper as [70]
Citations
Cites
Piezoelectric Nanogenerators Based on Zinc Oxide Nanowire Arrays
Wang, Z. L., & Song, J. (2006) · Science · doi:10.1126/science.1124005 · Cited by 7,922 · cited 1×
“Development of flexible devices based on arrays of piezoelectric ZnO nanowires (14, 15) represents an important step in this direction.”
Background1.6 V Nanogenerator for Mechanical Energy Harvesting Using PZT Nanofibers
Chen, X., Xu, S., Yao, N., & Shi, Y. (2010) · Nano Letters · doi:10.1021/nl100812k · Cited by 900
Human-powered wearable computing
Starner, T. (1996) · IBM Systems Journal · doi:10.1147/sj.353.0618 · Cited by 876 · cited 1×
“Investigations into energy-harvesting strategies to replace batteries demonstrate several unusual ways to extract power from chemical, mechanical, electrical, and thermal processes in the human body (1, 2).”
BackgroundPiezoelectric BaTiO3Thin Film Nanogenerator on Plastic Substrates
Park, K.-I., Xu, S., Liu, Y., Hwang, G.-T., Kang, S.-J. L., Wang, Z. L., & Lee, K. J. (2010) · Nano Letters · doi:10.1021/nl102959k · Cited by 827 · cited 1×
“Some improvement in performance is possible with thin-film geometries, as demonstrated in bending experiments on devices based on barium titanate (16) and lead zirconate titanate (PZT) (11, 12, 17).”
BackgroundFlexible High-Output Nanogenerator Based on Lateral ZnO Nanowire Array
Zhu, G., Yang, R., Wang, S., & Wang, Z. L. (2010) · Nano Letters · doi:10.1021/nl101973h · Cited by 805 · cited 2×
“[We note that alternative metrics for efficiency (13) lead to much higher values than those reported above.”
BackgroundQi, Y., Kim, J., Nguyen, T. D., Lisko, B., Purohit, P. K., & McAlpine, M. C. (2011) · Nano Letters · doi:10.1021/nl104412b · Cited by 516 · cited 1×
“Some improvement in performance is possible with thin-film geometries, as demonstrated in bending experiments on devices based on barium titanate (16) and lead zirconate titanate (PZT) (11, 12, 17).”
BackgroundImplanted Biofuel Cell Operating in a Living Snail
Halámková, L., Halámek, J., Bocharova, V., Szczupak, A., Alfonta, L., & Katz, E. (2012) · Journal of the American Chemical Society · doi:10.1021/ja211714w · Cited by 486 · cited 1×
“Examples include use of glucose oxidation (3), electric potentials of the inner ear (4), mechanical movements of limbs, and natural vibrations of internal organs (5–7).”
BackgroundChoi, M., Choi, D., Jin, M., Kim, I., Kim, S., Choi, J., Lee, S. Y., Kim, J. M., & Kim, S. (2009) · Advanced Materials · doi:10.1002/adma.200803605 · Cited by 439
Transient, Biocompatible Electronics and Energy Harvesters Based on ZnO
Dagdeviren, C., Hwang, S., Su, Y., Kim, S., Cheng, H., Gur, O., Haney, R., Omenetto, F. G., Huang, Y., & Rogers, J. A. (2013) · Small · doi:10.1002/smll.201300146 · Cited by 412 · cited 2×
“2F for ΔLmax = 10 mm) and work done (19) in each cycle RΔLmax 0 FdΔL, where F = 4π(2)wPIEIPI=L(2) is the bucking force (SI Appendix, Fig.”
BackgroundSelf-citationA very low-power CMOS mixed-signal IC for implantable pacemaker applications
Wong, L. S. Y., Hossain, S., Ta, A., Edvinsson, J., Rivas, D. H., & Naas, H. (2004) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2004.837027 · Cited by 395
Research works printed but not linked: 1
- FA Baciewicz, DG Penney, WA Marinelli, R Marinelli, Torsional ventricular motion and rotary blood flow. Cardiac Chronicle 5, 1–8 (1991).
Cited by
Items 901–998 of 998
Applications of Vibration-Based Energy Harvesting (VEH) Devices
Lee, O. B., Thein, C. K., Keat, Y. C., & Aziz, A. R. A. (2016) · IGI Global eBooks · doi:10.4018/978-1-5225-1671-2.ch031
Origins of Negative and Positive Electromechanical Response of Oligopeptide PiezoelectricsPreprint
Gayatri, N. N. D., & Hutchison, G. (2019) · ChemRxiv · doi:10.26434/chemrxiv.9985205
Implantable Piezoelectric Energy Harvesters
(2022) · Wiley eBooks · doi:10.1002/9783527833115.ch9
Design of Flexible Piezoelectric Energy Harvesters
Yang, B. T., Yi, Z., & Lee, C. (2022) · Wiley eBooks · doi:10.1002/9783527833115.ch2 · Cited by 1
Self-citationMizuyama, T., & Nishikawa, H. (2023) · Electronics and Communications in Japan · doi:10.1002/ecj.12386
Research on Transfer Printing Process Optimization for Flexible Piezoelectric Energy Harvester
Gao, Z., Li, C., Huang, H., Zeng, P., & Tian, H. (2023) · Panda Forum on Power and Energy (PandaFPE) · doi:10.1109/pandafpe57779.2023.10140827
Rathore, S. (2023) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/168825
MICRO ENERGY HARVESTER USING ACOUSTICALLY RESONATING BUBBLE FOR BIOMEDICAL IMPLANTATION
Li, W., Mercader, A. L., & Kwon, S. (2022) · Solid-State Sensors, Actuators, and Microsystems Workshop (Hilton Head Workshop) · doi:10.31438/trf.hh2022.49
“There are typically two methods to harvest energy biomedically, passive energy harvesting involves utilizing human movement such as heart movement or lung movement as energy source, while active energy harvesting involves using external energy source to transfer energy into human body [4].”
MethodKhazaee, M., Riahi, S., Rosendahl, L. A., & Rezania, A. (2023) · ECCOMAS Thematic Conference on Smart Structures and Materials (SMART) · doi:10.7712/150123.9969.444185
Mechanical Energy Harvesting Scheme, Implementation Aspects, and Applications
Singh, P. P., Singh, A. K., Nigam, S., & Singh, M. K. (2023) · EAI/Springer Innovations in Communication and Computing · doi:10.1007/978-3-031-35965-1_10
Paul, A., Bhattacharjee, M., & Dahiya, R. (2023) · Wiley eBooks · doi:10.1002/9781119473114.ch4 · Cited by 1
Additive Manufacturing in Electronics and Functional Devices
Hill, C. W., Kong, Y. L., Katz, H. B., Sabanosh, D. H., Beidaghi, M., Sakthivel, N., Vendra, L., Torbati-Sarraf, S. A., & Mahjouri‐Samani, M. (2023) · ASM International eBooks · doi:10.31399/asm.hb.v24a.a0006980
Advancements And Applications Of Piezoelectric Energy Harvesters: A Comprehensive Review
Dixit, N. K. (2024) · i-manager s Journal on Material Science · doi:10.26634/jms.11.3.20525 · Cited by 1
Nanwatkar, R. K. (2024) · Journal of Electrical Systems · doi:10.52783/jes.1988
Design of piezoelectric energy harvesters for cardiac applications based on medical image processing
Talebpour, L., Bhayadia, A. K., Olivett, A., & Karami, M. A. (2024) · Active and Passive Smart Structures and Integrated Systems · doi:10.1117/12.3011289
“4 However, the transition to leadless pacemakers unveils notable hurdles concerning the efficient generation of power from cardiac motion while simultaneously constraining the physical dimensions of the device.”
BackgroundLai, Q., Zhang, Y., Lu, B., Zhang, W., Lü, C., & Zhang, H. (2024) · Journal of Applied Mechanics · doi:10.1115/1.4066383
Self-citationDeposition of Ag nanostructures on PET substrates by DC Sputtering
Raj, D. V., Jayaram, N. D., & Chakravarty, S. (2024) · doi:10.54392/ara24116
Zhang, W., Lai, Q., & Zhang, J. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.5045107
Wijekoon, R., & Kularatna-Abeywardana, D. (2024) · IEEE Sustainable Power and Energy Conference (iSPEC) · doi:10.1109/ispec59716.2024.10892465
“While considering the power requirements of DBS systems, heart, lungs, and diaphragm motions show high potential as involuntary movements to harvest electrical energy [13].”
The Potential of Terahertz Technology to Revolutionize Cardiac Healthcare
Elmaadawy, S., Chan, I., & Jornet, J. M. (2025) · International Workshop on Mobile Terahertz Systems (IWMTS) · doi:10.1109/icmmts62835.2025.10925974
“One of the challenges is the device’s battery lifetime; however, some research groups are designing implantable nanoscale devices that convert the mechanical motion of the heart into electric energy [5].”
Scalable solutions for clean and affordable energy
Yirenkyi, G. N. A., Asare, E., Amakye, D. N., Tetteh, L. A., & Mensah, A. A. (2025) · International Journal of Advances in Electrical Engineering · doi:10.22271/27084574.2025.v6.i1a.86
Saroglia, G., Marocco, S., Nicoloso, S., Diana, S., Tozzi, M., & Stefanini, I. (2025) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2025.100645 · Cited by 1
Zhang, W., Meng, Y., Zhang, C., Yan, X., & Liu, C. (2025) · Composite Structures · doi:10.1016/j.compstruct.2025.119400
Harvesting Energy from Subclavian Artery Motion for Self-Powered Implantable Medical Devices
Wijekoon, R., & Kularatna-Abeywardana, D. (2025) · IEEE ECCE Asia Downunder · doi:10.1109/ecce-asia63110.2025.11111967
“While considering the power requirements of biomedical implantable systems, heart, artery, lungs, and diaphragm motions show high potential as involuntary movements to harvest electrical energy [7].”
Energy Harvesting Using Piezoelectric Shoe Technology from Cattle Livestock Movement
Kulkarni, A., & Kulkarni, S. (2025) · International Journal For Multidisciplinary Research · doi:10.36948/ijfmr.2025.v07i05.55461
Textile-based triboelectric nanogenerators as sensor device
Gaur, A., Kumar, A., Porwal, C., Jaswal, P., Chauhan, V. S., & Vaish, R. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-24074-4.00008-7
Smart sensors for graft health monitoring
Sharma, A., Gorantla, V. S., & Sonkusale, S. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-30084-4.00011-9
Demuynck, M. (2024) · Espace ÉTS (ETS)
Energy harvesting from pulsatile Superior Vena Cava for implantable devices
Abdelmageed, M. G., El-Bab, A. M. R. F., Abouelsoud, A. A., & Elsisy, M. M. (2025) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2025.116993
Wang, J., Zhou, Q., Lin, B., Wang, Q., Liu, F., & Lu, Z. (2025) · Results in Engineering · doi:10.1016/j.rineng.2025.107514
Magnetostrictive-piezoelectric composite arrays for human motion energy harvesting
Meng, K., Li, M., Liu, M., Gao, L., Weng, L., & Huang, W. (2025) · Engineering Research Express · doi:10.1088/2631-8695/ae30c9
Luo, L., Liu, L., Zhou, Y., Fu, Z., Liu, X., Chang, A., & Zhao, P. (2025) · Journal of Alloys and Compounds · doi:10.1016/j.jallcom.2025.185903
Attazada, Z., & Rafique, S. (2026) · BIG D · doi:10.64504/big.d.v3i1.327
“Piezoelectric pressure sensors generate electrical signals in response to applied mechanical stress and are particularly effective for detecting dynamic pressure changes [13,24].”
Wijekoon, R., & Kularatna-Abeywardana, D. (2025) · International Conference on Micro and Nanotechnology for Power Generation and Energy Conversion Applications (PowerMEMS) · doi:10.1109/powermems66515.2025.11358633
“Key sources of involuntary biomechanical motion include the heart, arteries, lungs, and diaphragm, with arterial and cardiac motions demonstrating the highest potential due to their relatively high frequency [7].”
Dynamic Analysis of a Pacemaker Lead Wire for Piezoelectric Energy Harvesting Applications
Hu, C. (2023) · TSpace (University of Toronto)
Wireless and Soft Pulse Wave Measurement Device with Printed Ferroelectric E‐tattoo Sensor
Montero, K. L., Du, Y., Kajas, N., Trueb, J. T., Peltokangas, M., Arafa, H., Kim, J., Gu, J., Guzman, R. C., Oksala, N., et al. (2026) · Advanced Sensor Research · doi:10.1002/adsr.202500145
“Lithographic patterning followed by transfer printing on a flexible substrate (e.g., polyimide) has previously been used for the fabrication of e-tattoo sensors [ 5, 7–9 ].”
Self-citationArtificial Intelligent Powered Flexible 3D Tactile Interactive Electronics
Qi, B., Xiang, Z., Huang, J., Zhu, S., Zhang, S., Zhang, G., Hu, Y., Li, G., Zhang, L., Kolaric, I., et al. (2026) · Engineering · doi:10.1016/j.eng.2026.02.026 · Cited by 1
Bio‐Inspired Mechanical Amplification Block on Implantable Tactile Sensors
Choi, S., Ye, Y., Jeong, C., Mun, Y., Oh, S., & Kim, T. (2026) · Advanced Electronic Materials · doi:10.1002/aelm.202500874
Flexible Eu–YbFeO₃/PVDF nanogenerators with improved β-phase formation and dielectric performance
Santhosi, K., & Patra, N. (2026) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2026.117791
Zno nanostructures for electronic and energy harvesting applications
Dahiya, A. S. (2016) · theses.fr (ABES) · doi:10.70675/350872a7zb7ecz469dz93d8z4a9e68f07651 · Cited by 1
Modeling of the behavior and rupture of the active materials
Viun, O. (2015) · theses.fr (ABES) · doi:10.70675/45683a3ez9f02z465ezbc69z677b7b9b1a43
Risquez, S. (2017) · theses.fr (ABES) · doi:10.70675/2f6cb34azea55z42fez8b94z6270dbf7711a · Cited by 3
Régulation de l'activité pacemaker cardiaque par les phosphodiestérases
de Vasconcelos, W. P. (2023) · theses.fr (ABES) · doi:10.70675/5e129148z3995z4fecza3b9zd8ec77d92271
Asymmetric and multi-step switching ejection strategy for ultrathin chip-peeling process
Chen, S., Kong, Z., Yin, H., Chen, Y., Jiao, W., Zhu, F., & Ma, Y. (2026) · International Journal of Solids and Structures · doi:10.1016/j.ijsolstr.2026.114051
Identifying ferroelectricity in organic compounds
Litterst, M. (2026) · doi:10.11588/heidok.00038586
Energy Harvesting Using Piezoelectric Plates for RFID Applications
Bhagwat, S., Goyanka, D., Hande, A., Jadhav, H., Hade, V., Govekar, O., Suryawanshi, H. R., & Gode, O. (2026) · Lecture notes in networks and systems · doi:10.1007/978-3-032-19672-9_13
Udoisoh, M. G., Ekanem, E. M., Emmanuel, R. I., Onoja, O. P., & Meko, O. A. (2026) · Research Square · doi:10.21203/rs.3.rs-9037903/v1
Singh, P. K., Sharma, A., & Dwivedi, D. K. (2026) · Solid State Communications · doi:10.1016/j.ssc.2026.116464
Anderson, R., Whitlow, S., & Deerland, M. (2026) · International Journal of Research Publication and Reviews · doi:10.55248/gengpi.07.0526.d1115
Ion-Selective Sensors for Orthopaedic Applications: A Systematic Review
Polidori, G., Visani, A., Giavaresi, G., Serpelloni, M., & Marchiori, G. (2026) · Biosensors · doi:10.3390/bios16060302
“Importantly, fully implantable piezoelectric systems have been evaluated in vivo in large-animal models, harvesting energy directly from the motion of the heart, lungs, and diaphragm at levels compatible with low-power medical electronics [86].”
Multifunctional Lightweight Polymer-based Hybrid Composites for Piezoelectric Sensing
Serrano, A. X. (2026) · SHAREOK (University of Oklahoma; Oklahoma State University; Central Oklahoma University)
Flexible piezoelectric 0-3 PGSZT-PDMS composite film for self-powered vital signs monitoringPreprint
Deng, J., Xu, J., Liu, C., (694142), Y. Y., Zou, J., Wang, X., Luo, J., Long, H., Zhang, K., Lan, H., et al. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.6881185
Cao, X., Hu, J., Pang, Q., Jiang, Q., Chen, S., & Luo, B. (2026) · Journal of Functional Biomaterials · doi:10.3390/jfb17060278
“For the intraosseous segment, inorganic or inorganic-dominant composite surfaces remain more realistic in the near term [20,57,74–78,80 Poly(lactic acid) and poly(L-lactic acid) (PLA/PLLA), peptide assemblies, silk fibroin, collagen, and other biodegradable piezoelectric materials are also…”
Ezzin, H., Monchetti, S., Puddu, P. E., Teresi, L., DeSimone, A., & Brighenti, R. (2026) · Advanced Materials Technologies · doi:10.1002/admt.71087
Kouritem, S. A., Elkhoby, S., Magdy, G., Hassanin, A. H., & Shehata, N. (2026) · Journal of Materials Science Materials in Electronics · doi:10.1007/s10854-026-17730-x
“The heart serves as a reliable source of mechanical energy (pump), which can be converted into electrical energy through optimized piezoelectric energy harvesters to operate pacemakers [65].”
Packaging Challenges for Energy-Autonomous IoT Sensing
Rusu, C., & Staaf, H. (2026) · IMAPS Nordic Conference on Microelectronics Packaging (NordPac) · doi:10.23919/nordpac69911.2026.11568270
“Recent advances in ultra-low-power electronics have reduced system consumption to the µW – mW range, enabling rapid development of energy harvesting solutions [5,14,15].”
Piezo-supercapacitors for wearable electronics and smart fabrics
Sonia, S., Jeba, S. V., Uthaya, G., & Ahamed, M. B. (2026) · Elsevier eBooks · doi:10.1016/b978-0-443-27558-6.00012-3
NANOTEKNOLOJİ ve ENERJİ HASADI: PİEZOELEKTRİK NANOMALZEMELERİN GELECEĞİ
Tüylek, Z. (2026) · Mühendis ve Makina · doi:10.46399/muhendismakina.1778974
Kristiansen, A. (2026) · SSRN Electronic Journal · doi:10.2139/ssrn.6921299
Advances in Electromagnetic Compatibility for Biomedical Wearable and Implantable Devices
Liu, K., Xu, G., & Geng, D. (2026) · Asia-Pacific International Symposium on Electromagnetic Compatibility (APEMC) · doi:10.1109/apemc65388.2026.11593641
Sharma, K., Svendsen, M. B. S., Naik, D. A., & Boisen, A. (2026) · Royal Society of Chemistry eBooks · doi:10.1039/9781837679850-00285
Tian, S., Wang, Z., Gao, D., & Li, A. (2026) · Chem & Bio Engineering · doi:10.1021/cbe.6c00056
Advances in smart and multifunctional composite materials: design, mechanisms, and applications
Singh, S., Kamble, Z., Kumari, R., & Neje, G. (2026) · Functional Composites and Structures · doi:10.1088/2631-6331/ae9372
Energy Harvesting Behavior of Multifunctional Layered Composites
Chen, B., Soutis, C., Jia, Y., & Shi, Y. (2026) · Wiley eBooks · doi:10.1002/9783527844982.ch03
Silk fibroin-based wearable bioelectronics for self-powered healthcare
Ansari, A. I., & Dekhtyar, Y. (2026) · International Journal on Interactive Design and Manufacturing (IJIDeM) · doi:10.1007/s12008-026-02669-4
“Furthermore, integration of nanogenerators with biosensors has enabled self-powered electrochemical detection driven by biomechanical energy [66–68].”
Finite Element Analysis of Piezoelectric Energy Harvesting from Runway Surface
Shetty, S., Aabid, A., Baig, M., & Khan, S. A. (2026) · Lecture notes in civil engineering · doi:10.1007/978-981-92-2743-3_6
Quintero-Agredo, M. M., Jurado, S. G., Sandoval-Ceron, D. M., & Raigoza, C. F. V. (2026) · Journal of Composite Materials · doi:10.1177/00219983261472165
Hashem, R., El-Hussieny, H., Umezu, S., & El‐Bab, A. M. R. F. (2026) · International Journal of Intelligent Robotics and Applications · doi:10.1007/s41315-026-00567-2
Pandey, A., & Pandey, A. (2026) · Microsystem Technologies · doi:10.1007/s00542-026-06127-9
“In this approach the PEH device is mounted directly on the epicardial surface of the heart and converts the mechani 2014 ) consider a basic capacitor structure in which the PZT layer is embedded between the bottom (Ti/Pt, 20 nm/300 nm) and top (Cr/Au, 10 nm/200 nm) electrodes.”
Vishwakarma, A., Murali, N., Verma, A., Sabu, S., Rahman, A., Mondal, S., Betal, S., Spackman, M. A., Karumuthil, S. C., & Thomas, S. P. (2026) · Advanced Energy Materials · doi:10.1002/aenm.71458
Self-sustaining leadless intracardiac pacemaker powered by triboelectric nanogenerator
Chen, P., Wang, R., Schmuck, E. G., Wang, D., Modaff, D. S., Zhou, T., Osaki, S., Liu, W., Pan, F., Kim, J., et al. (2026) · Science Advances · doi:10.1126/sciadv.aef8903 · Cited by 1
“Piezoelectric nano-generators ( 29 – 31 ) offer a more compact option by converting myocardial deformation into charge with flexible structures, but their performance is limited by low electromechanical coupling efficiency and concerns about lead-containing ceramics.”
Seelam, L., Mahanty, B., & Gajula, P. (2026) · Journal of Industrial and Engineering Chemistry · doi:10.1016/j.jiec.2026.08.039
Anari, S., Rahi, A., & Shahravi, M. (2026) · Forces in Mechanics · doi:10.1016/j.finmec.2026.100383
Zhang, M., Wang, H., Liu, H., Zhao, D., Wu, J., & Ma, T. (2026) · iScience · doi:10.1016/j.isci.2026.117396
“9 Furthermore, long-term retention of such materials in vivo can trigger chronic inflammation and foreign body response.”
Khalafzadeh, S., Pesaran, F., & Shiri, N. (2026) · Journal of Computational Electronics · doi:10.1007/s10825-026-02634-0
“The selection of an appropriate physiological energy source is a critical consideration in implantable energy harvesting systems [1].”
InfluentialHumanoidalne roboty podwodne ESA-HAUV w obsłudze technicznej budowli hydrotechnicznych
PALECZEK, W. (2026) · GAZ WODA I TECHNIKA SANITARNA · doi:10.65545/gwits.2026.07.06
Satır, Ü., Oflaz, K., Kara, G., Uzer, D., Kurukavak, Ç. K., Argun, M. E., Sarıipek, F. B., & Özaytekin, İ. (2026) · Polymers for Advanced Technologies · doi:10.1002/pat.70745
Upadhyay, A. (2026) · IntechOpen eBooks · doi:10.5772/intechopen.1016929
Electromagnetic Non-Resonant Vibration Energy Harvesters with Linear Magnetic Gear
Wang, J., & Kim, E. S. (2026) · Micromachines · doi:10.3390/mi17101121
“…locomotion, joint articulation, heel strike, and limb oscillation, generate substantial kinetic energy, while underlying physiological processes, including myocardial contractions, hemodynamic flow, and gastrointestinal peristalsis, contribute mechanical and thermal energy at the organ level [4].”
Rony, A., Ushasree, P. M., Short, M., & Narayanan, J. A. (2026) · Advanced Intelligent Systems · doi:10.1002/aisy.70541
Gao, S., Wang, Y., Li, A., Chen, S., Che, H., Meng, X., Chen, Y., Lijuan, H., Bai, Y., & Lin, Y. (2026) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2026.119291
Energy Harvesting Systems in Smart Mechanical Structures
Mzeh, H. K., & Salabi, L. (2025) · Journal of Reconfigurable Hardware Architectures and Embedded Systems
Recent Advances in Bio-Piezoelectric Materials and Sensors
Lee, S. B., Lim, S. J., & Kim, J. (2026) · Ceramist · doi:10.31613/ceramist.2026.00220
A biohybrid mesh harvester for distributed energy harvesting in living tissues
Wang, S., Wang, X., Fu, S., Senger, C., Pfund, J. D., Jain, M., Katsumata, R., & Yao, J. (2026) · Science Advances · doi:10.1126/sciadv.aei5963
“The packaging not only introduces potential invasiveness to the biosystem but also reduces the effective energy conversion density (e.g., sub-μ W/cm 3 in existing piezoelectric implants) ( 15 , 17 ).”
Razek, A. (2026) · Micromachines · doi:10.3390/mi17101176
“Regarding wearable energy harvesting, it can be associated to heart rate [138,139], respiration [140,141], pulse [142], and gastric cavity deformation [143].”
Li, Z., Ke, Y., Prasad, V., Han, Z., Thomas, I., Cazade, P., Yang, F., & Li, J. (2026) · Advanced Healthcare Materials · doi:10.1002/adhm.71848
Koshiba, Y., KUBO, Y., Kawasaki, Y., Kawano, S., Akiyama, A., Matsumoto, T., Horike, S., Nishino, T., Ishida, K., & Funahashi, M. (2026) · Japanese Journal of Applied Physics · doi:10.35848/1347-4065/aeb4c2
Gu, M., Zhao, H., Bai, L., Sun, R., Li, Z., Li, Y., Yu, F., Lin, N., 程秀凤, Li, L., et al. (2026) · Chemical Engineering Journal · doi:10.1016/j.cej.2026.183080
Magnetically gated millimeter-scale capsule power system for leadless electrotherapy
Yang, F., Tian, Y., Zhang, E., Yang, L., You, Z., Peng, P., Han, Q., Du, Y., Li, H., Wu, Y., et al. (2026) · Science Advances · doi:10.1126/sciadv.aeh6700
“To overcome these constraints, battery-free approaches based on wireless power transfer ( 4 , 28 , 29 ) and energy harvesting ( 30 – 40 ) have been actively explored.”
From Fall Detection to Predictive Healthcare Logistics: A Framework for AI-Driven Risk Anticipation
Abate, R., Mattera, G., Guizzi, G., & Abate, A. (2026) · Lecture notes in bioengineering · doi:10.1007/978-3-032-32938-7_5
Multidomain signal-driven Endoleak detection using a self-powered piezoelectric Smart Stent
Selvarajan, S., Eskanos, I., Tan, J. Y., Mou, T. D., Kim, J., Lee, S., & Kim, A. (2026) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2026.100848
Chen, J., Zou, M., An, D., Zhang, Y., Xu, F., Li, M., Zhao, Y., Li, Z., Lin, Z., & Zhao, L. (2026) · Nano Energy · doi:10.1016/j.nanoen.2026.112540
Yadav, C., Lade, J., Dabhi, V. M., Singh, S., Manchanda, R., Bhowmik, A., Gupta, R., & Mehta, A. (2026) · Textile Progress · doi:10.1080/00405167.2026.2731841
Biological material PVDF: Challenges in peripheral nerve fascicle regeneration
Xi, Z., & Shen, W. (2026) · Journal of Bioactive and Compatible Polymers · doi:10.1177/08839115261500877
Metadata
- Authors
- Dagdeviren, C., Yang, B. D., Su, Y., Tran, P. L., Joe, P., Anderson, E., Xia, J., Doraiswamy, V., Dehdashti, B., Feng, X., Lu, B., Poston, R., Khalpey, Z., Ghaffari, R., Huang, Y., Slepian, M. J., & Rogers, J. A.
- Affiliations
- Department of Materials Science and Engineering, Beckman Institute for Advanced Science and Technology, and Frederick Seitz Materials Research Laboratory, and
- Northwestern University (US)
- Department of Medicine and Sarver Heart Center and
- Departments of eSurgery and
- Tsinghua University (CN)
- Center for Mechanics and Materials and
- MC10 (United States) (US)
- University of Arizona (US)
- University of Illinois Urbana-Champaign (US)
- ORCID
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2014-01-21
- Volume
- 111
- Issue
- 5
- Pages
- 1927-1932
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC3918766
- OpenAlex
- W2151263439
- Semantic Scholar
- cc964bc8a81953562c1114871f1173d22240d91c
- Cited by
- 975
- References
- 33
- Citations by year
- 2026: 73 · 2025: 80 · 2024: 66 · 2023: 63 · 2022: 89 · 2021: 83 · 2020: 96 · 2019: 90 · 2018: 100 · 2017: 83 · 2016: 68 · 2015: 52 · 2014: 32
- FWCI
- 91.20
- Type
- journal article
- Language
- en
- Update notices
- correction (2021-07-19)
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) (submittedVersion)
- Funders
- U.S. Department of Energy (DEFG0207ER46471)
- National Institute of Biomedical Imaging and Bioengineering (U01EB012487)
- Topics
- Physical Sciences › Engineering › Mechanical Engineering › Innovative Energy Harvesting Technologies
- Physical Sciences › Engineering › Biomedical Engineering › Advanced Sensor and Energy Harvesting Materials
- Physical Sciences › Energy › Nuclear Energy and Engineering › Advanced Energy Technologies and Civil Engineering Innovations
- Keywords
- piezoelectric energy harvesting, mechanical-to-electrical energy conversion, cardiac motion, lung motion, diaphragm motion, rectifier, cardiac pacemaker, implantable power sources, animal models
- MeSH terms
- Animals, Cattle, Diaphragm, Heart, Humans, Lung, Motion, Electric Power Supplies, Sheep, Rats, Electrophysiological Phenomena
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.