The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Deep, noninvasive imaging and surgical guidance of submillimeter tumors using targeted M13-stabilized single-walled carbon nanotubes
Open accessAbstract
Significance: Early detection of cancer positively impacts diagnosis and treatment, ultimately improving patient survival. Using fluorescence imaging offers the promise of safe, noninvasive detection with excellent resolution and guides surgical removal of tumors to improve patient outcomes. However, the success of current optical probes is limited due to high background from tissue autofluorescence, poor penetration depth, and inherently low signal stability. Here, we engineered M13 bacteriophage to stabilize single-walled carbon nanotubes for selective, targeted imaging of ovarian tumors. These nanoprobes fluoresce at longer near-infrared wavelengths than current probes, thereby improving noninvasive detection of small, deep tumors and guidance for surgical removal of submillimeter tumors. This material-based approach may be attractive to guide surgical interventions where deep tissue molecular imaging is informative.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Welsher, K., Sherlock, S. P., & Dai, H. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1014501108 · Cited by 958
Optical properties of human skin in the near infrared wavelength range of 1000 to 2200 nm
Troy, T. L., & Thennadil, S. N. (2001) · Journal of Biomedical Optics · doi:10.1117/1.1344191 · Cited by 420
Cited by
Near-infrared fluorophores for biomedical imaging
Hong, G., Antaris, A. L., & Dai, H. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-016-0010 · Cited by 2,985
Carbon Nanomaterials for Biological Imaging and Nanomedicinal Therapy
Hong, G., Diao, S., Antaris, A. L., & Dai, H. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00008 · Cited by 1,394
Advanced Fluorescence Imaging Technology in the Near-Infrared-II Window for Biomedical Applications
Li, C., Chen, G., Zhang, Y., Wu, F., & Wang, Q. (2020) · Journal of the American Chemical Society · doi:10.1021/jacs.0c07022 · Cited by 1,037
He, S., Song, J., Qu, J., & Cheng, Z. (2018) · Chemical Society Reviews · doi:10.1039/c8cs00234g · Cited by 1,021
Recent Advances of Optical Imaging in the Second Near‐Infrared Window
Kenry, Duan, Y., & Liu, B. (2018) · Advanced Materials · doi:10.1002/adma.201802394 · Cited by 810
Metadata
- Authors
- Ghosh, D., Bagley, A. F., Na, Y. J., Birrer, M. J., Bhatia, S. N., & Belcher, A. M.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2014-09-11
- Volume
- 111
- Issue
- 38
- Pages
- 13948-13953
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W1965003174
- Cited by
- 251
- References
- 2
- FWCI
- 10.59
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.