Voltage-sensitive dye imaging of transcranial magnetic stimulation-induced intracortical dynamics
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Significance: Transcranial magnetic stimulation (TMS) is significant for medical diagnostics, therapeutic treatment, and basic brain research. However, highly resolved observations of its immediate effects remained obscured because existing techniques are limited in spatial or temporal resolutions and are severely disturbed by the high magnetic fields. Here, we avoid these limitations, using optical imaging with voltage-sensitive dye (VSD) in the cat animal model. VSD transforms changes in neuronal membrane voltage into optical signals, providing microsecond resolution and evading contamination by electromagnetic artifacts. We visualize TMS-induced cortical dynamics and characterize effects on visual processing over scales of milliseconds, minutes, and hours. Combined TMS and VSD imaging offers a powerful approach to study targeted modifications in cortical function during TMS-based plasticity and learning protocols.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Interneurons of the neocortical inhibitory system
Markram, H., Toledo-Rodriguez, M., Wang, Y., Gupta, A., Silberberg, G., & Wu, C. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1519 · Cited by 2,954 · cited 1×
“Because of their soma targeting on pyramidal neurons (58), and possibly because of their far-reaching axonal-dendritic structure (59) enhancing TMS sensitivity (60), these interneurons may impose strong synchronized inhibition in the affected cortical network (10).”
BackgroundDepression of motor cortex excitability by low-frequency transcranial magnetic stimulation
Chen, R., Classen, J., Gerloff, C., Celnik, P., Wassermann, E. M., Hallett, M., & Cohen, L. G. (1997) · Neurology · doi:10.1212/wnl.48.5.1398 · Cited by 2,128 · cited 1×
“Similar effects of increased or decreased excitability dependent on TMS frequency were originally found in motor cortex (63, 64).”
BackgroundStructural and molecular interrogation of intact biological systems
Chung, K., Wallace, J., Kim, S.-Y., Kalyanasundaram, S., Andalman, A. S., Davidson, T. J., Mirzabekov, J. J., Zalocusky, K. A., Mattis, J., Denisin, A. K., et al. (2013) · Nature · doi:10.1038/nature12107 · Cited by 2,008 · cited 1×
“Because of their soma targeting on pyramidal neurons (58), and possibly because of their far-reaching axonal-dendritic structure (59) enhancing TMS sensitivity (60), these interneurons may impose strong synchronized inhibition in the affected cortical network (10).”
BackgroundPascual-Leone, A. (2000) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(00)00081-7 · Cited by 923 · cited 1×
“Because of their soma targeting on pyramidal neurons (58), and possibly because of their far-reaching axonal-dendritic structure (59) enhancing TMS sensitivity (60), these interneurons may impose strong synchronized inhibition in the affected cortical network (10).”
BackgroundDifferential effects on motorcortical inhibition induced by blockade of GABA uptake in humans
Werhahn, K. J., Kunesch, E., Noachtar, S., Benecke, R., & Classen, J. (1999) · The Journal of Physiology · doi:10.1111/j.1469-7793.1999.0591t.x · Cited by 887
Transcranial magnetic stimulation and cognitive neuroscience
Walsh, V., & Cowey, A. (2000) · Nature Reviews Neuroscience · doi:10.1038/35036239 · Cited by 814
Sillito, A. M. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp011056 · Cited by 742
Is there a future for therapeutic use of transcranial magnetic stimulation?
Ridding, M. C., & Rothwell, J. C. (2007) · Nature Reviews Neuroscience · doi:10.1038/nrn2169 · Cited by 687
Physiology of repetitive transcranial magnetic stimulation of the human brain
Hoogendam, J. M., Ramakers, G. M. J., & Di Lazzaro, V. (2010) · Brain Stimulation · doi:10.1016/j.brs.2009.10.005 · Cited by 669
VSDI: a new era in functional imaging of cortical dynamics
Grinvald, A., & Hildesheim, R. (2004) · Nature Reviews Neuroscience · doi:10.1038/nrn1536 · Cited by 618 · cited 1×
“Proc Natl Acad Sci USA 103(33):12586–12591.”
Cited by
Siebner, H. R., Funke, K., Aberra, A. S., Antal, A., Bestmann, S., Chen, R., Classen, J., Davare, M., Di Lazzaro, V., Fox, P. T., et al. (2022) · Clinical Neurophysiology · doi:10.1016/j.clinph.2022.04.022 · Cited by 566
Brain circuits for pain and its treatment
Mercer Lindsay, N., Chen, C., Gilam, G., Mackey, S., & Scherrer, G. (2021) · Science Translational Medicine · doi:10.1126/scitranslmed.abj7360 · Cited by 229
“In vivo voltage dye imaging in cat cortex found a progressive rise in excitation at the targeted region throughout a 10-Hz electrical stimulus train (300), supporting previous slice electrophysiology studies that had similarly concluded that high-frequency stimulation in cortical tissue preferentially activates excita…”
ResultUsing fMRI connectivity to define a treatment-resistant form of post-traumatic stress disorder
Etkin, A., Maron-Katz, A., Wu, W., Fonzo, G. A., Huemer, J., Vértes, P. E., Patenaude, B., Richiardi, J., Goodkind, M. S., Keller, C. J., et al. (2019) · Science Translational Medicine · doi:10.1126/scitranslmed.aal3236 · Cited by 103
“In that study, repetitive stimulation at 10 Hz, which is thought to increase neuronal excitability (34), resulted in increased within-VAN resting-state fMRI connectivity but only after stimulation of the right side of the VAN target.”
BackgroundDufor, T., Lohof, A. M., & Sherrard, R. M. (2023) · International Journal of Molecular Sciences · doi:10.3390/ijms242216456 · Cited by 28
“Both whole-cell recordings and voltage-sensitive dyes show that magnetic pulses initiate a transient current into neurons through voltage-gated sodium channels [72,73].”
Metadata
- Authors
- Kozyrev, V., Eysel, U. T., & Jancke, D.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2014-09-03
- Volume
- 111
- Issue
- 37
- Pages
- 13553-13558
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2107236474
- Cited by
- 74
- References
- 11
- FWCI
- 4.21
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.