Simultaneous cryo X-ray ptychographic and fluorescence microscopy of green algae
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Significance: X-ray fluorescence microscopy provides unparalleled sensitivity for measuring the distribution of trace elements in many-micrometer-thick specimens, whereas ptychography offers a path to the imaging of weakly fluorescing biological ultrastructure at beyond-focusing-optic resolution. We demonstrate here for the first time, to our knowledge, the combination of fluorescence and ptychography for imaging frozen-hydrated specimens at cryogenic temperatures, with excellent structural and chemical preservation. This combined approach will have significant impact on studies of the intracellular localization of nanocomposites with attached therapeutic or diagnostic agents, help elucidate the roles of trace metals in cell development, and further the study of diseases where trace metal misregulation is suspected (including neurodegenerative diseases).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Chlamydomonas Genome Reveals the Evolution of Key Animal and Plant Functions
Merchant, S. S., Prochnik, S. E., Vallon, O., Harris, E. H., Karpowicz, S. J., Witman, G. B., Terry, A., Salamov, A., Fritz-Laylin, L. K., Maréchal-Drouard, L., et al. (2007) · Science · doi:10.1126/science.1143609 · Cited by 2,691 · cited 1×
“We have also imaged the unicellular green algae Chlamydomonas reinhardtii, which serves as a model organism for molecular genetic studies (47, 48).”
MethodCryo-electron microscopy of vitrified specimens
Dubochet, J., Adrian, M., Chang, J.-J., Homo, J.-C., Lepault, J., McDowall, A. W., & Schultz, P. (1988) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500004297 · Cited by 2,389 · cited 1×
“Cryogenic samples can provide highfidelity structural (31) and ionic elemental (32–34) preservation, and mitigate the effects of radiation damage (35).”
BackgroundMiao, J., Charalambous, P., Kirz, J., & Sayre, D. (1999) · Nature · doi:10.1038/22498 · Cited by 1,976
Atomic radiative and radiationless yields for K and L shells
Krause, M. O. (1979) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555594 · Cited by 1,970 · cited 3×
“However, XFM does not usually show much cellular ultrastructure, because the light elements (such as H, C, N, and O, which are the main constituents of biological materials) have low fluorescence yield (4).”
BackgroundMethodInfluentialEfficient subpixel image registration algorithms
Guizar-Sicairos, M., Thurman, S. T., & Fienup, J. R. (2008) · Optics Letters · doi:10.1364/ol.33.000156 · Cited by 1,905 · cited 1×
“Before computing the FRC, the two phase images were aligned with subpixel precision using an efficient image method based on cross-correlation (66) and then were multiplied by a soft-edged mask (Tukey window) to avoid correlation from the image field boundaries.”
MethodReconstruction of an object from the modulus of its Fourier transform
Fienup, J. R. (1978) · Optics Letters · doi:10.1364/ol.3.000027 · Cited by 1,836 · cited 1×
“The traditional CDI approach requires that samples meet a so-called “finite support” (17) requirement with no observable scattering outside of a defined region; although some limited success has been obtained (18, 19), this finite support condition has proven difficult to achieve with single cells surrounded by ice la…”
BackgroundAn improved ptychographical phase retrieval algorithm for diffractive imaging
Maiden, A. M., & Rodenburg, J. M. (2009) · Ultramicroscopy · doi:10.1016/j.ultramic.2009.05.012 · Cited by 1,496 · cited 2×
“Each subset was reconstructed using the ePIE algorithm (45) with the multimode modification proposed by Thibault and Menzel (37) with GPU parallel programming.”
MethodHigh-Resolution Scanning X-ray Diffraction Microscopy
Thibault, P., Dierolf, M., Menzel, A., Bunk, O., David, C., & Pfeiffer, F. (2008) · Science · doi:10.1126/science.1158573 · Cited by 1,321 · cited 2×
“Ptychography allows for the recovery of both the probe and the complex object transmission function (22).”
BackgroundMethodPhase-contrast imaging of weakly absorbing materials using hard X-rays
Davis, T. J., Gao, D., Gureyev, T. E., Stevenson, A. W., & Wilkins, S. W. (1995) · Nature · doi:10.1038/373595a0 · Cited by 1,010 · cited 3×
“We therefore propagated that probe mode upstream and downstream to see if our data were acquired at the proper focus (6).”
BackgroundFourier shell correlation threshold criteria
van Heel, M., & Schatz, M. (2005) · Journal of Structural Biology · doi:10.1016/j.jsb.2005.05.009 · Cited by 927 · cited 9×
“5 shows the computed FRC as a function of spatial frequency.”
MethodInfluential
Cited by
X-Rays and Extreme Ultraviolet Radiation: Principles and Applications
Attwood, D., & Sakdinawat, A. (2016) · CERN Document Server (European Organization for Nuclear Research) · doi:10.1017/cbo9781107477629 · Cited by 644
Lin, F., Liu, Y., Yu, X., Cheng, L., Singer, A., Shpyrko, O. G., Xin, H. L., Tamura, N., Tian, C., Weng, T.-C., et al. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00007 · Cited by 582
Imaging metals in biology: balancing sensitivity, selectivity and spatial resolution
Hare, D. J., New, E. J., de Jonge, M. D., & McColl, G. (2015) · Chemical Society Reviews · doi:10.1039/c5cs00055f · Cited by 201
Ackerman, C. M., Lee, S., & Chang, C. J. (2017) · Analytical Chemistry · doi:10.1021/acs.analchem.6b04631 · Cited by 177
Metadata
- Authors
- Deng, J., Vine, D. J., Chen, S., Nashed, Y. S. G., Jin, Q., Phillips, N. W., Peterka, T., Ross, R., Vogt, S., & Jacobsen, C. J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2015-02-09
- Volume
- 112
- Issue
- 8
- Pages
- 2314-2319
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2126888116
- Cited by
- 180
- References
- 53
- FWCI
- 26.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.