Simultaneous cryo X-ray ptychographic and fluorescence microscopy of green algae
Open accessThe DOI matches its Crossref record; 53 of the 53 references it cites were found in a registry or an index.
Abstract
Significance: X-ray fluorescence microscopy provides unparalleled sensitivity for measuring the distribution of trace elements in many-micrometer-thick specimens, whereas ptychography offers a path to the imaging of weakly fluorescing biological ultrastructure at beyond-focusing-optic resolution. We demonstrate here for the first time, to our knowledge, the combination of fluorescence and ptychography for imaging frozen-hydrated specimens at cryogenic temperatures, with excellent structural and chemical preservation. This combined approach will have significant impact on studies of the intracellular localization of nanocomposites with attached therapeutic or diagnostic agents, help elucidate the roles of trace metals in cell development, and further the study of diseases where trace metal misregulation is suspected (including neurodegenerative diseases).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Chlamydomonas Genome Reveals the Evolution of Key Animal and Plant Functions
Merchant, S. S., Prochnik, S. E., Vallon, O., Harris, E. H., Karpowicz, S. J., Witman, G. B., Terry, A., Salamov, A., Fritz-Laylin, L. K., Maréchal-Drouard, L., et al. (2007) · Science · doi:10.1126/science.1143609 · Cited by 2,691 · cited 1×
“We have also imaged the unicellular green algae Chlamydomonas reinhardtii, which serves as a model organism for molecular genetic studies (47, 48).”
MethodCryo-electron microscopy of vitrified specimens
Dubochet, J., Adrian, M., Chang, J.-J., Homo, J.-C., Lepault, J., McDowall, A. W., & Schultz, P. (1988) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500004297 · Cited by 2,389 · cited 1×
“Cryogenic samples can provide highfidelity structural (31) and ionic elemental (32–34) preservation, and mitigate the effects of radiation damage (35).”
BackgroundMiao, J., Charalambous, P., Kirz, J., & Sayre, D. (1999) · Nature · doi:10.1038/22498 · Cited by 1,976
Atomic radiative and radiationless yields for K and L shells
Krause, M. O. (1979) · Journal of Physical and Chemical Reference Data · doi:10.1063/1.555594 · Cited by 1,970 · cited 3×
“However, XFM does not usually show much cellular ultrastructure, because the light elements (such as H, C, N, and O, which are the main constituents of biological materials) have low fluorescence yield (4).”
BackgroundMethodInfluentialEfficient subpixel image registration algorithms
Guizar-Sicairos, M., Thurman, S. T., & Fienup, J. R. (2008) · Optics Letters · doi:10.1364/ol.33.000156 · Cited by 1,905 · cited 1×
“Before computing the FRC, the two phase images were aligned with subpixel precision using an efficient image method based on cross-correlation (66) and then were multiplied by a soft-edged mask (Tukey window) to avoid correlation from the image field boundaries.”
MethodReconstruction of an object from the modulus of its Fourier transform
Fienup, J. R. (1978) · Optics Letters · doi:10.1364/ol.3.000027 · Cited by 1,836 · cited 1×
“The traditional CDI approach requires that samples meet a so-called “finite support” (17) requirement with no observable scattering outside of a defined region; although some limited success has been obtained (18, 19), this finite support condition has proven difficult to achieve with single cells surrounded by ice la…”
BackgroundAn improved ptychographical phase retrieval algorithm for diffractive imaging
Maiden, A. M., & Rodenburg, J. M. (2009) · Ultramicroscopy · doi:10.1016/j.ultramic.2009.05.012 · Cited by 1,496 · cited 2×
“Each subset was reconstructed using the ePIE algorithm (45) with the multimode modification proposed by Thibault and Menzel (37) with GPU parallel programming.”
MethodHigh-Resolution Scanning X-ray Diffraction Microscopy
Thibault, P., Dierolf, M., Menzel, A., Bunk, O., David, C., & Pfeiffer, F. (2008) · Science · doi:10.1126/science.1158573 · Cited by 1,321 · cited 2×
“Ptychography allows for the recovery of both the probe and the complex object transmission function (22).”
BackgroundMethodPhase-contrast imaging of weakly absorbing materials using hard X-rays
Davis, T. J., Gao, D., Gureyev, T. E., Stevenson, A. W., & Wilkins, S. W. (1995) · Nature · doi:10.1038/373595a0 · Cited by 1,010 · cited 3×
“We therefore propagated that probe mode upstream and downstream to see if our data were acquired at the proper focus (6).”
BackgroundFourier shell correlation threshold criteria
van Heel, M., & Schatz, M. (2005) · Journal of Structural Biology · doi:10.1016/j.jsb.2005.05.009 · Cited by 927 · cited 9×
“5 shows the computed FRC as a function of spatial frequency.”
MethodInfluentialPtychographic X-ray computed tomography at the nanoscale
Dierolf, M., Menzel, A., Thibault, P., Schneider, P., Kewish, C. M., Wepf, R., Bunk, O., & Pfeiffer, F. (2010) · Nature · doi:10.1038/nature09419 · Cited by 926 · cited 2×
“This is different from the practice in many other ptychography experiments where a coherent beam spot of ∼ 300–3000 nm is scanned in a spiral pattern with overlaps, yielding a smaller number of diffraction patterns (27, 39, 40).”
BackgroundResultThe correlation averaging of a regularly arranged bacterial cell envelope protein
Saxton, W. O., & Baumeister, W. (1982) · Journal of Microscopy · doi:10.1111/j.1365-2818.1982.tb00405.x · Cited by 872 · cited 9×
“5 shows the computed FRC as a function of spatial frequency.”
MethodInfluentialHard-X-Ray Lensless Imaging of Extended Objects
Rodenburg, J. M., Hurst, A. C., Cullis, A. G., Dobson, B. R., Pfeiffer, F., Bunk, O., David, C., Jefimovs, K., & Johnson, I. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.034801 · Cited by 855
Jeon, H., Lee, H., Kang, K. H., & Lim, G. (2014) · Scientific Reports · doi:10.1038/srep06668 · Cited by 844
Movable Aperture Lensless Transmission Microscopy: A Novel Phase Retrieval Algorithm
Faulkner, H. M. L., & Rodenburg, J. M. (2004) · Physical Review Letters · doi:10.1103/physrevlett.93.023903 · Cited by 839
C HLAMYDOMONAS AS A M ODEL O RGANISM
Harris, E. H. (2001) · Annual Review of Plant Physiology and Plant Molecular Biology · doi:10.1146/annurev.arplant.52.1.363 · Cited by 711 · cited 1×
“We have also imaged the unicellular green algae Chlamydomonas reinhardtii, which serves as a model organism for molecular genetic studies (47, 48).”
MethodSoft X-ray microscopes and their biological applications
Kirz, J., Jacobsen, C., & Howells, M. (1995) · Quarterly Reviews of Biophysics · doi:10.1017/s0033583500003139 · Cited by 672 · cited 1×
“However, radiation damage limits the achievable resolution in X-ray microscopy of hydrated biological specimens (28).”
BackgroundSelf-citationHigh-resolution ab initio three-dimensional x-ray diffraction microscopy
Chapman, H. N., Barty, A., Marchesini, S., Noy, A., Hau-Riege, S. P., Cui, C., Howells, M. R., Rosen, R., He, H., Spence, J. C. H., et al. (2006) · Journal of the Optical Society of America A · doi:10.1364/josaa.23.001179 · Cited by 592 · cited 3×
“For traditional CDI involving a single diffraction pattern, the phase retrieval transfer function (PRTF) (53) [also called the intensity 500 nm K S”
BackgroundInfluentialSelf-citationBiological imaging by soft x-ray diffraction microscopy
Shapiro, D., Thibault, P., Beetz, T., Elser, V., Howells, M., Jacobsen, C., Kirz, J., Lima, E., Miao, H., Neiman, A. M., et al. (2005) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0503305102 · Cited by 554 · cited 2×
“ratio (14)] is a commonly used method to assess resolution by finding the finest periodicity at which phases are consistent in iterative phase retrieval (Fig.”
MethodResultSelf-citationAn assessment of the resolution limitation due to radiation-damage in X-ray diffraction microscopy
Howells, M. R., Beetz, T., Chapman, H. N., Cui, C., Holton, J. M., Jacobsen, C. J., Kirz, J., Lima, E., Marchesini, S., Miao, H., et al. (2009) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/j.elspec.2008.10.008 · Cited by 524 · cited 1×
“This f∼−3:5 signal decrease is consistent with what is observed in model objects (41), in scanning X-ray microscope images (42, 43), and in other CDI and ptychography experiments (14, 25).”
ResultSelf-citationCryotechniques in biological electron microscopy
(1988) · Comparative Biochemistry and Physiology Part A Physiology · doi:10.1016/0300-9629(88)90980-2 · Cited by 397
X-ray ptychographic computed tomography at 16 nm isotropic 3D resolution
Holler, M., Diaz, A., Guizar-Sicairos, M., Karvinen, P., Färm, E., Härkönen, E., Ritala, M., Menzel, A., Raabe, J., & Bunk, O. (2014) · Scientific Reports · doi:10.1038/srep03857 · Cited by 357 · cited 2×
“This is different from the practice in many other ptychography experiments where a coherent beam spot of ∼ 300–3000 nm is scanned in a spiral pattern with overlaps, yielding a smaller number of diffraction patterns (27, 39, 40).”
MethodResultExperimental determination of the radiation dose limit for cryocooled protein crystals
Owen, R. L., Rudiño-Piñera, E., & Garman, E. F. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0600973103 · Cited by 356 · cited 1×
“The estimated radiation dose imparted to the specimen with 3-s exposure times per (40 nm)(2) pixel was about 1:4× 109 Gy, which is above the 4:3×107-Gy dose at which atom-to-atom spatial correlations are significantly reduced as observed in X-ray diffraction patterns (63), but well below the dose (which we estimate to…”
MethodInfluence of the overlap parameter on the convergence of the ptychographical iterative engine
Bunk, O., Dierolf, M., Kynde, S., Johnson, I., Marti, O., & Pfeiffer, F. (2008) · Ultramicroscopy · doi:10.1016/j.ultramic.2007.08.003 · Cited by 307
Fahrni, C. J. (2007) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2007.02.039 · Cited by 297 · cited 11×
“J Electron Spectrosc Relat Phenom 170(1-3):”
InfluentialLarabell, C. A., & Le Gros, M. A. (2004) · Molecular Biology of the Cell · doi:10.1091/mbc.e03-07-0522 · Cited by 282 · cited 1×
“Compared with “water window” soft X-ray tomography (30, 58, 59), tomography with multi-keV X-rays offers the capability for increased sample thickness, and increased depth of focus for a given spatial resolution, which allows this combined method to image larger cells and tissue sections in 3D.”
Imaging whole Escherichia coli bacteria by using single-particle x-ray diffraction
Miao, J., Hodgson, K. O., Ishikawa, T., Larabell, C. A., LeGros, M. A., & Nishino, Y. (2003) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.232691299 · Cited by 276 · cited 1×
“Proc Natl Acad Sci USA 103(13):4912–4917.”
Zinc availability regulates exit from meiosis in maturing mammalian oocytes
Kim, A. M., Vogt, S., O'Halloran, T. V., & Woodruff, T. K. (2010) · Nature Chemical Biology · doi:10.1038/nchembio.419 · Cited by 271 · cited 1×
“This method will aid the interpretation of studies of the localization of nanoparticles attached to therapeutic agents (1, 60), or the role of metals in cell development (61), and in diseases where trace metal misregulation is implicated as a cause (62).”
MethodSelf-citationSTRUCTURE AND DEVELOPMENT OF THE CHLOROPLAST IN CHLAMYDOMONAS
Sager, R., & Palade, G. E. (1957) · The Journal of Cell Biology · doi:10.1083/jcb.3.3.463 · Cited by 270 · cited 1×
“A starch sheath with gaps between starch plates is formed at the periphery of the pyrenoid (49, 50).”
BackgroundX‐ray fluorescence microprobe imaging in biology and medicine
Paunesku, T., Vogt, S., Maser, J., Lai, B., & Woloschak, G. (2006) · Journal of Cellular Biochemistry · doi:10.1002/jcb.21047 · Cited by 251 · cited 13×
“J Electron Spectrosc Relat Phenom 170(1-3):”
MethodInfluentialSelf-citationDiffraction-limited imaging in a scanning transmission x-ray microscope
Jacobsen, C., Williams, S., Anderson, E., Browne, M. T., Buckley, C. J., Kern, D., Kirz, J., Rivers, M., & Zhang, X. (1991) · Optics Communications · doi:10.1016/0030-4018(91)90016-7 · Cited by 244 · cited 1×
“This f∼−3:5 signal decrease is consistent with what is observed in model objects (41), in scanning X-ray microscope images (42, 43), and in other CDI and ptychography experiments (14, 25).”
ResultSelf-citationRuiz, F. A., Marchesini, N., Seufferheld, M., Govindjee, & Docampo, R. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m105268200 · Cited by 210 · cited 1×
“Structural and elemental features of polyphosphate bodies have been studied by electron microscopy and X-ray microanalysis, respectively (51, 52), whereas both of these are simultaneously revealed in our study.”
BackgroundVila-Comamala, J., Diaz, A., Guizar-Sicairos, M., Mantion, A., Kewish, C. M., Menzel, A., Bunk, O., & David, C. (2011) · Optics Express · doi:10.1364/oe.19.021333 · Cited by 191 · cited 2×
“This is different from the practice in many other ptychography experiments where a coherent beam spot of ∼ 300–3000 nm is scanned in a spiral pattern with overlaps, yielding a smaller number of diffraction patterns (27, 39, 40).”
BackgroundResultCryotechniques in Biological Electron Microscopy
(1987) · Springer eBooks · doi:10.1007/978-3-642-72815-0 · Cited by 178
The Bionanoprobe: hard X-ray fluorescence nanoprobe with cryogenic capabilities
Chen, S., Deng, J., Yuan, Y., Flachenecker, C., Mak, R., Hornberger, B., Jin, Q., Shu, D., Lai, B., Maser, J., et al. (2014) · Journal of Synchrotron Radiation · doi:10.1107/s1600577513029676 · Cited by 177 · cited 5×
“Ptychography and fluorescence scanning experiments were conducted at the Bionanoprobe at the 21-ID-D beamline of the Advanced Photon Source, Argonne National Laboratory.”
BackgroundInfluentialSelf-citationQuantitative 3D elemental microtomography of Cyclotella meneghiniana at 400-nm resolution
de Jonge, M. D., Holzner, C., Baines, S. B., Twining, B. S., Ignatyev, K., Diaz, J., Howard, D. L., Legnini, D., Miceli, A., McNulty, I., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1001469107 · Cited by 161 · cited 1×
“Although we show here 2D images, both ptychography (39) and fluorescence (57) are compatible with tomographic approaches to nanoscale 3D imaging of biological materials.”
BackgroundSelf-citation3-D Ultrastructure of O. tauri: Electron Cryotomography of an Entire Eukaryotic Cell
Henderson, G. P., Gan, L., & Jensen, G. J. (2007) · PLoS ONE · doi:10.1371/journal.pone.0000749 · Cited by 142 · cited 2×
“The arrow points to structures that resemble ribosome-like complexes observed in cryo electron microscopy studies of similar algae (46).”
BackgroundParallel ptychographic reconstruction
Nashed, Y. S. G., Vine, D. J., Peterka, T., Deng, J., Ross, R., & Jacobsen, C. J. (2014) · Optics Express · doi:10.1364/oe.22.032082 · Cited by 131
Self-citationHigh-resolution x-ray diffraction microscopy of specifically labeled yeast cells
Weker, J. N., Huang, X., Steinbrener, J., Shapiro, D. A., Kirz, J., Marchesini, S., Neiman, A. M., Turner, J. J., & Jacobsen, C. J. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0910874107 · Cited by 128
Self-citationMajumdar, S., Peralta-Videa, J. R., Castillo-Michel, H. A., Hong, J. N., Rico, C. M., & Gardea-Torresdey, J. L. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.09.050 · Cited by 126 · cited 2×
“J Electron Spectrosc Relat Phenom 170(1-3):”
Zernike phase contrast in scanning microscopy with X-rays
Holzner, C., Feser, M., Vogt, S., Hornberger, B., Baines, S. B., & Jacobsen, C. J. (2010) · Nature Physics · doi:10.1038/nphys1765 · Cited by 124
Self-citationWilson Disease at a Single Cell Level
Ralle, M., Hüster, D., Vogt, S., Schirrmeister, W., Burkhead, J. L., Capps, T. R., Gray, L. W., Lai, B. C. H., Maryon, E. B., & Lutsenko, S. (2010) · Journal of Biological Chemistry · doi:10.1074/jbc.m110.114447 · Cited by 123 · cited 1×
“This method will aid the interpretation of studies of the localization of nanoparticles attached to therapeutic agents (1, 60), or the role of metals in cell development (61), and in diseases where trace metal misregulation is implicated as a cause (62).”
MethodSelf-citationYuan, Y., Chen, S., Paunesku, T., Gleber, S. C., Liu, W. C., Doty, C. B., Mak, R., Deng, J., Jin, Q., Lai, B. C. H., et al. (2013) · ACS Nano · doi:10.1021/nn4033294 · Cited by 122 · cited 1×
“This method will aid the interpretation of studies of the localization of nanoparticles attached to therapeutic agents (1, 60), or the role of metals in cell development (61), and in diseases where trace metal misregulation is implicated as a cause (62).”
MethodSelf-citationKosior, E., Bohic, S., Suhonen, H., Ortega, R., Devès, G., Carmona, A., Marchi, F., Guillet, J. F., & Cloetens, P. (2011) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.12.005 · Cited by 104
Elemental mapping of frozen‐hydrated cells with cryo‐scanning X‐ray fluorescence microscopy
Matsuyama, S., Shimura, M., Fujii, M., Maeshima, K., Yumoto, H., Mimura, H., Sano, Y., Yabashi, M., Nishino, Y., Tamasaku, K., et al. (2010) · X-Ray Spectrometry · doi:10.1002/xrs.1256 · Cited by 97
Biomedical applications of the ESRF synchrotron-based microspectroscopy platform
Bohic, S., Cotte, M., Salome-Pateyron, M., Fayard, B., Kühbacher, M., Cloetens, P., Martínez‐Criado, G., Tucoulou, R., & Susini, J. (2011) · Journal of Structural Biology · doi:10.1016/j.jsb.2011.12.006 · Cited by 91
Komine, Y., Eggink, L. L., Park, H., & Hoober, J. K. (2000) · Planta · doi:10.1007/s004250050695 · Cited by 86 · cited 2×
“Several electron-dense spherical structures in the ptychographic image show large amounts of P and Ca in fluorescence maps, presumably representing polyphosphate bodies that contain polyphosphate complexed with calcium (51).”
BackgroundA hard x-ray nanoprobe for scanning and projection nanotomography
Bleuet, P., Cloetens, P., Gergaud, P., Mariolle, D., Chevalier, N., Tucoulou, R., Susini, J., & Chabli, A. (2009) · Review of Scientific Instruments · doi:10.1063/1.3117489 · Cited by 85
Differential phase contrast with a segmented detector in a scanning X-ray microprobe
Hornberger, B., de Jonge, M. D., Feser, M., Holl, P., Holzner, C., Jacobsen, C. J., Legnini, D. G., Paterson, D. J., Řehák, P., Strüder, L., et al. (2008) · Journal of Synchrotron Radiation · doi:10.1107/s0909049508008509 · Cited by 83
Self-citationLeapman, R. D. (2003) · Journal of Microscopy · doi:10.1046/j.1365-2818.2003.01173.x · Cited by 79 · cited 1×
“The estimated radiation dose imparted to the specimen with 3-s exposure times per (40 nm)(2) pixel was about 1:4× 109 Gy, which is above the 4:3×107-Gy dose at which atom-to-atom spatial correlations are significantly reduced as observed in X-ray diffraction patterns (63), but well below the dose (which we estimate to…”
MethodSimultaneous X-ray fluorescence and ptychographic microscopy of Cyclotella meneghiniana
Vine, D. J., Pelliccia, D., Holzner, C., Baines, S. B., Berry, A., McNulty, I., Vogt, S., Peele, A. G., & Nugent, K. A. (2012) · Optics Express · doi:10.1364/oe.20.018287 · Cited by 78 · cited 3×
“Second, as the spatial resolution of fluorescence imaging is limited by the beam size, the focused beam needs to be as small as possible (24, 38) (about 80-nm FWHM for the combined probe modes in our experiment; see Fig.”
BackgroundMethodSelf-citationRawat, M., Henk, M. C., Lavigne, L. L., & Moroney, J. V. (1996) · Planta · doi:10.1007/bf00206252 · Cited by 63 · cited 1×
“A starch sheath with gaps between starch plates is formed at the periphery of the pyrenoid (49, 50).”
BackgroundCryo‐scanning x‐ray diffraction microscopy of frozen‐hydrated yeast
Lima, E., Díaz, A., Guizar‐Sicairos, M., Gorelick, S., Pernot, P., Schleier, T., & Menzel, A. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03682.x · Cited by 54 · cited 1×
“Ptychography has been used to image freeze-dried diatoms at 30-nm resolution (24) and bacteria at 20-nm resolution (25), and frozen-hydrated yeast at 85-nm resolution (26), whereas ptychographic tomography has been used to image nanoporous glass to 16-nm 3D resolution (27).”
Method
Cited by
X-Rays and Extreme Ultraviolet Radiation: Principles and Applications
Attwood, D., & Sakdinawat, A. (2016) · CERN Document Server (European Organization for Nuclear Research) · doi:10.1017/cbo9781107477629 · Cited by 644
Lin, F., Liu, Y., Yu, X., Cheng, L., Singer, A., Shpyrko, O. G., Xin, H. L., Tamura, N., Tian, C., Weng, T.-C., et al. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.7b00007 · Cited by 582
Metadata
- Authors
- Deng, J., Vine, D. J., Chen, S., Nashed, Y. S. G., Jin, Q., Phillips, N. W., Peterka, T., Ross, R., Vogt, S., & Jacobsen, C. J.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2015-02-09
- Volume
- 112
- Issue
- 8
- Pages
- 2314-2319
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2126888116
- Cited by
- 180
- References
- 53
- FWCI
- 26.44
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.